{
 "id": "eptfw0gt9w",
 "slug": "3d-electron-diffraction",
 "title": "3D electron diffraction",
 "updated": "2026-10-25",
 "topic_path": [
  {
   "id": "physical",
   "label": "Physical world and mathematics",
   "api_url": "https://www.edgepedia.org/api/v1/topics/physical"
  },
  {
   "id": "physical.physics",
   "label": "Physics",
   "api_url": "https://www.edgepedia.org/api/v1/topics/physical.physics"
  },
  {
   "id": "physical.physics.matter-and-radiation",
   "label": "Matter and radiation physics",
   "api_url": "https://www.edgepedia.org/api/v1/topics/physical.physics.matter-and-radiation"
  },
  {
   "id": "physical.physics.matter-and-radiation.condensed-matter",
   "label": "Condensed matter physics",
   "api_url": "https://www.edgepedia.org/api/v1/topics/physical.physics.matter-and-radiation.condensed-matter"
  },
  {
   "id": "physical.physics.matter-and-radiation.condensed-matter.cm-structures",
   "label": "Crystal and structural condensed matter",
   "api_url": "https://www.edgepedia.org/api/v1/topics/physical.physics.matter-and-radiation.condensed-matter.cm-structures"
  }
 ],
 "geo": [
  {
   "id": "geo.nongeo.t2001.physical.physics.matter-and-radiation",
   "label": "Non-geographic · 2001 to 2020: Matter and radiation physics",
   "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t2001.physical.physics.matter-and-radiation",
   "path": [
    {
     "id": "geo.nongeo",
     "label": "Non-geographic",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo"
    },
    {
     "id": "geo.nongeo.t2001",
     "label": "Non-geographic · 2001 to 2020",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t2001"
    },
    {
     "id": "geo.nongeo.t2001.physical",
     "label": "Physical world and mathematics",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t2001.physical"
    },
    {
     "id": "geo.nongeo.t2001.physical.physics",
     "label": "Physics",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t2001.physical.physics"
    },
    {
     "id": "geo.nongeo.t2001.physical.physics.matter-and-radiation",
     "label": "Matter and radiation physics",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t2001.physical.physics.matter-and-radiation"
    }
   ]
  }
 ],
 "excerpt": "3D electron diffraction (3D ED), including the MicroED and automated diffraction tomography (ADT) techniques, is a crystallographic method that determines structures of nanocrystals too small for X-ray diffraction.",
 "snippet": "3D electron diffraction (3D ED), including the MicroED and automated diffraction tomography (ADT) techniques, is a crystallographic method that determines structures of nanocrystals too small for X-ray diffraction.",
 "node": "physical.physics.matter-and-radiation.condensed-matter.cm-structures",
 "markdown": "# 3D electron diffraction\n\n3D electron diffraction (3D ED) is a crystallographic method that collects electron diffraction patterns while tilting a single nanocrystal inside a transmission electron microscope (TEM), reconstructing a three-dimensional diffraction volume from which the crystal structure is solved. It exists to determine structures of crystals too small for single-crystal [X-ray diffraction](https://www.edgepedia.org/x-ray-diffraction), typically well below 5 × 5 × 5 μm³, exploiting the much stronger interaction of electrons with matter.<sup>[1](https://pubs.rsc.org/en/content/articlehtml/2022/ce/d2ce00051b)</sup> The name \"3D ED\" serves as an umbrella term for a family of techniques that collect reflection intensities in three-dimensional reciprocal space (mathematical space where diffraction patterns are represented); the original term is automated diffraction tomography (ADT) and the most popular is [MicroED](https://www.edgepedia.org/microed), with RED, cRED, EDT, IEDT, and PEDT also in use.<sup>[2](https://pubs.acs.org/doi/full/10.1021/acs.chemrev.1c00207)</sup>\n\n| Key fact | Detail |\n|---|---|\n| Crystal size range | A few tens of nanometers up to about 1 μm thick; between 1 and 5 μm, 200 keV electrons are absorbed<sup>[2](https://pubs.acs.org/doi/full/10.1021/acs.chemrev.1c00207)</sup> |\n| Best resolution | 0.55 Å for small organic and inorganic compounds, matching X-ray limits<sup>[2](https://pubs.acs.org/doi/full/10.1021/acs.chemrev.1c00207)</sup> |\n| Typical kinematical refinement | R1 of 18–40% and GooF of 1.4–2.8 for crystals thicker than 100 nm, versus R1 of 2.5% for X-ray small-molecule data<sup>[3](https://pmc.ncbi.nlm.nih.gov/articles/PMC6716134/)</sup> |\n| Dynamical refinement gain | Improves structural accuracy by a factor of 2–3, to about 0.02 Å average error in atomic positions<sup>[3](https://pmc.ncbi.nlm.nih.gov/articles/PMC6716134/)</sup> |\n| Collection speed | A full continuous-rotation dataset in a few tens of seconds at dose rates around 0.01 e⁻ s⁻¹ Å⁻² with fast hybrid detectors<sup>[3](https://pmc.ncbi.nlm.nih.gov/articles/PMC6716134/)</sup> |\n| Main hardware constraint | Goniometer tilt limited to roughly 120–150°, leaving a missing wedge of reciprocal space<sup>[3](https://pmc.ncbi.nlm.nih.gov/articles/PMC6716134/)</sup> |\n| Detectors | Hybrid pixel detectors: 20 bit or more dynamic range, negligible read-out time and noise, image rates above 1 kHz<sup>[2](https://pubs.acs.org/doi/full/10.1021/acs.chemrev.1c00207)</sup> |\n\n## How it works\n\nRotating the crystal under the beam sweeps the Ewald sphere (geometric construct mapping diffraction conditions in crystallography) through reciprocal space, so each tilt step records a different planar section of the diffraction volume; the rotation method produces a contiguous section of reciprocal space, and became continuous shutterless collection once detectors with negligible readout time were available.<sup>[4](https://pubs.acs.org/doi/full/10.1021/acs.chemrev.1c00879)</sup> Elastic electron scattering is dictated by the electrostatic potential V(r) of the sample, and the strong Coulombic interaction means tractable diffraction arises from crystals of about 10⁻² μm³, many orders of magnitude smaller in volume than conventional X-ray diffraction requires.<sup>[4](https://pubs.acs.org/doi/full/10.1021/acs.chemrev.1c00879)</sup>\n\nIntensities are normally interpreted in the kinematical approximation, where the diffracted intensity of reflection \\( h \\) is proportional to \\( |F_{h}|^{2} \\). Collecting patterns in off-zone orientations, away from major zone axes, keeps dynamical effects manageable, and nanoscale mosaicity and inelastic scattering further mitigate them.<sup>[5](https://www.mdpi.com/2073-8994/15/8/1555)</sup>\n\nMultiple elastic scattering nevertheless makes measured intensities deviate from the kinematical proportionality, worsening R-factors and producing non-zero intensities for systematically absent reflections.<sup>[6](https://www.nature.com/articles/s41557-023-01186-1)</sup> Dynamical refinement, which computes intensities from dynamical diffraction theory instead, improves structural accuracy typically by a factor of 2–3 over kinematical refinement, reducing the average error of atomic positions to about 0.02 Å.<sup>[3](https://pmc.ncbi.nlm.nih.gov/articles/PMC6716134/)</sup> It was first implemented for precession tomography data in a 2015 Acta Crystallographica A paper by Lukáš Palatinus, Václav Petříček, and Cinthia Antunes Corrêa.<sup>[7](https://doi.org/10.1107/s2053273315001266)</sup> Extending it to continuous-rotation data required subdividing the experimental orientations into overlapping virtual frames (OVFs) and numerically integrating rocking curves; refinement uses JANA2006 (or Jana2020) with the Bloch-wave program Dyngo; in Jana2020, dynamical refinement has been modified to allow use of the improved Dingo program, which supersedes Dyngo.<sup>[6](https://www.nature.com/articles/s41557-023-01186-1)</sup> Because dynamical intensities are intrinsically sensitive to absolute structure, refinement can determine the absolute configuration of non-centrosymmetric crystals from diffraction data alone, which the kinematical approximation cannot.<sup>[6](https://www.nature.com/articles/s41557-023-01186-1)</sup>\n\n## How it is done\n\nCrystals are deposited on 3.05 mm TEM grids, typically with amorphous carbon support films thinner than 10 nm.<sup>[2](https://pubs.acs.org/doi/full/10.1021/acs.chemrev.1c00207)</sup> A crystal is selected and centered in the beam; beam diameters are usually below 1.5 μm, and the crystal must be centered to within half the beam diameter.<sup>[2](https://pubs.acs.org/doi/full/10.1021/acs.chemrev.1c00207)</sup> For organic compounds and proteins, a crystal thickness of the order of 500 nm along the scanned directions gives an optimal trade-off between signal and background.<sup>[5](https://www.mdpi.com/2073-8994/15/8/1555)</sup>\n\nData are then collected in shutterless continuous-rotation mode at scan speeds of typically 0.5–3 s/° and fluxes of 1 × 10⁻³ to 5 × 10⁻³ e⁻/(Å²·s); small-molecule wedges of 90–125° accumulate total doses of 0.1–10 e⁻/Å² per run.<sup>[5](https://www.mdpi.com/2073-8994/15/8/1555)</sup> Data reduction performs shift correction, peak hunting, three-dimensional reflection identification, unit-cell determination, and indexing, using dedicated suites such as ADT3D, PETS, and RED, or adapted X-ray programs including XDS, DIALS, and iMosFlm.<sup>[3](https://pmc.ncbi.nlm.nih.gov/articles/PMC6716134/)</sup><sup> • </sup><sup>[8](https://journals.iucr.org/j/issues/2013/06/00/nb5079/nb5079.pdf)</sup> Above about 1.2 Å resolution, ab initio solution proceeds by direct methods with SHELX, SIR2019, or SUPERFLIP, followed by least-squares refinement in SHELXL or JANA2006; small-molecule structures are commonly solved and refined in Olex2 with SHELXT and SHELXL back-ends.<sup>[1](https://pubs.rsc.org/en/content/articlehtml/2022/ce/d2ce00051b)</sup><sup> • </sup><sup>[5](https://www.mdpi.com/2073-8994/15/8/1555)</sup> Dedicated electron diffractometers, such as the Rigaku XtaLAB Synergy-ED developed with JEOL, remove the requirement of prior TEM-operation skill.<sup>[5](https://www.mdpi.com/2073-8994/15/8/1555)</sup>\n\n## Origin\n\nThe RED software for automated data collection and processing was reported in 2013 in the [Journal of Applied Crystallography](https://www.edgepedia.org/journal-of-applied-crystallography) by Wei Wan and colleagues.<sup>[9](https://doi.org/10.1107/s0021889813027714)</sup> [Continuous rotation electron diffraction](https://www.edgepedia.org/continuous-rotation-electron-diffraction) was first reported the same year by Igor Nederlof and colleagues in Acta Crystallographica Section D, for submicrometre protein crystals with a [Medipix](https://www.edgepedia.org/medipix) detector.<sup>[10](https://doi.org/10.1107/s0907444913009700)</sup> The MicroED protocol for protein microcrystals, collecting up to 90 diffraction patterns from one very small three-dimensional crystal, was reported in 2013 by Dan Shi and colleagues in eLife.<sup>[11](https://doi.org/10.7554/elife.01345)</sup> Fast electron diffraction tomography followed in 2015 in the Journal of Applied Crystallography by Mauro Gemmi and colleagues,<sup>[12](https://doi.org/10.1107/s1600576715004604)</sup> high-throughput software-automated cRED in 2018 by Magdalena Ola Cichocka and colleagues,<sup>[13](https://doi.org/10.1107/s1600576718015145)</sup> and the umbrella term \"3D ED\" in a 2019 ACS Central Science paper by Mauro Gemmi and colleagues.<sup>[14](https://doi.org/10.1021/acscentsci.9b00394)</sup>\n\n## Variants\n\nThe named protocols, including ADT, RED, PEDT, cRED, EDT, fast-EDT, fast-ADT, LD-EDT, and MicroED, all record diffraction patterns while tilting a crystal around the goniometer axis; they differ in stepwise versus continuous collection and in how the missing wedge of stepwise schemes is filled.<sup>[1](https://pubs.rsc.org/en/content/articlehtml/2022/ce/d2ce00051b)</sup> Stepwise schemes sample reciprocal space discretely. ADT uses discrete goniometer tilt steps of typically 1°, often combined with continuous beam precession, and relies on specialized hardware for precession and STEM-mode crystal tracking.<sup>[8](https://journals.iucr.org/j/issues/2013/06/00/nb5079/nb5079.pdf)</sup> RED combines coarse goniometer steps of typically 2–3° with very fine beam-tilt steps of 0.05–0.20° driven by the TEM deflection coils, reducing the effective angular step below 0.1°; it runs on a conventional TEM under software control without additional hardware.<sup>[8](https://journals.iucr.org/j/issues/2013/06/00/nb5079/nb5079.pdf)</sup><sup> • </sup><sup>[3](https://pmc.ncbi.nlm.nih.gov/articles/PMC6716134/)</sup> Fast-EDT uses a continuous stage tilt with crystal tracking based on a preliminary recording of the crystal movement, and couples beam precession to the continuous tilt.<sup>[15](https://journals.iucr.org/b/issues/2019/04/00/je5012/je5012.pdf)</sup> Continuous rotation is known under the names MicroED, IEDT, and cRED, is the strategy that minimizes electron dose, making it the common choice for beam-sensitive materials such as small organic molecules and proteins, and has been the predominant acquisition mode since 2019, with a setup analogous to the standard X-ray rotation method.<sup>[3](https://pmc.ncbi.nlm.nih.gov/articles/PMC6716134/)</sup><sup> • </sup><sup>[6](https://www.nature.com/articles/s41557-023-01186-1)</sup>\n\n## Applications\n\n3D ED is applied wherever crystals are too small or too scarce for X-ray work. In zeolites and porous materials, the calcined silicalite-1 structure with 72 unique atoms was solved from RED data by routine direct methods,<sup>[8](https://journals.iucr.org/j/issues/2013/06/00/nb5079/nb5079.pdf)</sup> and the method supports structural analysis of MOF nanocrystals despite their beam sensitivity, relevant to heterogeneous catalysis, gas adsorption and separation, sensing, energy storage, and drug delivery; TEM measurement additionally allows crystal morphology to be imaged.<sup>[1](https://pubs.rsc.org/en/content/articlehtml/2022/ce/d2ce00051b)</sup> Pharmaceutical examples include paracetamol<sup>[3](https://pmc.ncbi.nlm.nih.gov/articles/PMC6716134/)</sup> and S-ibuprofen.<sup>[16](https://repository.uantwerpen.be/docman/irua/c56c12motoMb7)</sup> Protein microcrystals of thaumatin have been solved by molecular replacement with PHASER and refined with REFMAC5 using sum-of-Gaussian scattering factors.<sup>[5](https://www.mdpi.com/2073-8994/15/8/1555)</sup>\n\n## Limitations and alternatives\n\n[Electron diffraction](https://www.edgepedia.org/electron-diffraction) works on crystals from a few tens of nanometers to about 1 μm thick; between 1 and 5 μm, depending on composition, 200 keV electrons are absorbed, and above roughly 5 μm [X-ray crystallography](https://www.edgepedia.org/x-ray-crystallography) takes over.<sup>[2](https://pubs.acs.org/doi/full/10.1021/acs.chemrev.1c00207)</sup> The dominant limitation is dynamical scattering, which biases kinematically refined structures and is worst for low accelerating voltages, near-perfect crystals, zone-axis alignment, and thick dense samples.<sup>[4](https://pubs.acs.org/doi/full/10.1021/acs.chemrev.1c00879)</sup> The goniometer tilt range is capped, so a missing cone of reciprocal space remains and highly complete datasets from a single crystal can be difficult; merging data from multiple crystals is an effective remedy, and rotation is usually limited to about 150° because the holder blocks the beam beyond ±75° off horizontal.<sup>[2](https://pubs.acs.org/doi/full/10.1021/acs.chemrev.1c00207)</sup> TEM optics distortions cause unit-cell imprecision of up to several percent in cell lengths and up to half a degree in angles, so cell accuracy falls short of [SCXRD](https://www.edgepedia.org/single-crystal-x-ray-diffraction) and powder XRD.<sup>[17](https://pmc.ncbi.nlm.nih.gov/articles/PMC12164520/)</sup> Refinement statistics also lag: kinematical R1 values of 18–40% for crystals thicker than 100 nm, against 2.5% for X-ray small-molecule data.<sup>[3](https://pmc.ncbi.nlm.nih.gov/articles/PMC6716134/)</sup> Cost runs the other way: a mid- to high-end TEM equipped for ED carries a six-digit price tag, up to an order of magnitude more than a standard X-ray diffractometer.<sup>[4](https://pubs.acs.org/doi/full/10.1021/acs.chemrev.1c00879)</sup> The methods are complementary: final structural models from 3D ED and SCXRD agree even in fine details once dynamical refinement is used, and 3D ED wins decisively on crystal size.<sup>[1](https://pubs.rsc.org/en/content/articlehtml/2022/ce/d2ce00051b)</sup>\n\n## References\n\n1. [Three-dimensional electron diffraction: a powerful structural characterization technique for crystal engineering (CrystEngComm, 2022)](https://pubs.rsc.org/en/content/articlehtml/2022/ce/d2ce00051b)\n2. [3D Electron Diffraction for Chemical Analysis: Instrumentation Developments and Innovative Applications (Chemical Reviews, 2022)](https://pubs.acs.org/doi/full/10.1021/acs.chemrev.1c00207)\n3. [3D Electron Diffraction: The Nanocrystallography Revolution (Gemmi et al., ACS Central Science 2019)](https://pmc.ncbi.nlm.nih.gov/articles/PMC6716134/)\n4. [Electron Diffraction of 3D Molecular Crystals (Chemical Reviews, 2022)](https://pubs.acs.org/doi/full/10.1021/acs.chemrev.1c00879)\n5. [Making the Most of 3D Electron Diffraction: Best Practices to Handle a New Tool (Symmetry, 2023)](https://www.mdpi.com/2073-8994/15/8/1555)\n6. [Accurate structure models and absolute configuration determination using dynamical effects in continuous-rotation 3D electron diffraction data (Nature Chemistry, 2023)](https://www.nature.com/articles/s41557-023-01186-1)\n7. [Lukáš Palatinus, Václav Petříček, Cinthia Antunes Corrêa (2015). Structure refinement using precession electron diffraction tomography and dynamical diffraction: theory and implementation. Acta Crystallographica Section A Foundations and Advances.](https://doi.org/10.1107/s2053273315001266)\n8. [Three-dimensional rotation electron diffraction: software RED for automated data collection and data processing (Zhang, Wan, Zou et al., J. Appl. Cryst. 2013)](https://journals.iucr.org/j/issues/2013/06/00/nb5079/nb5079.pdf)\n9. [Wei Wan and colleagues (2013). Three-dimensional rotation electron diffraction: software RED for automated data collection and data processing. Journal of Applied Crystallography.](https://doi.org/10.1107/s0021889813027714)\n10. [Igor Nederlof and colleagues (2013). A Medipix quantum area detector allows rotation electron diffraction data collection from submicrometre three-dimensional protein crystals. Acta Crystallographica Section D Biological Crystallography.](https://doi.org/10.1107/s0907444913009700)\n11. [Dan Shi and colleagues (2013). Three-dimensional electron crystallography of protein microcrystals. eLife.](https://doi.org/10.7554/elife.01345)\n12. [Mauro Gemmi and colleagues (2015). Fast electron diffraction tomography. Journal of Applied Crystallography.](https://doi.org/10.1107/s1600576715004604)\n13. [Magdalena Ola Cichocka and colleagues (2018). High-throughput continuous rotation electron diffraction data acquisition via software automation. Journal of Applied Crystallography.](https://doi.org/10.1107/s1600576718015145)\n14. [Mauro Gemmi and colleagues (2019). 3D Electron Diffraction: The Nanocrystallography Revolution. ACS Central Science.](https://doi.org/10.1021/acscentsci.9b00394)\n15. [Automated electron diffraction tomography – development and applications (Kolb group review, Acta Cryst. B 2019)](https://journals.iucr.org/b/issues/2019/04/00/je5012/je5012.pdf)\n16. [Round robin on structure analysis from 3D electron diffraction data (multi-laboratory benchmark, IUCrJ)](https://repository.uantwerpen.be/docman/irua/c56c12motoMb7)\n17. [3D Electron Diffraction on Nanoparticles: Minimal Size and Associated Dynamical Effects (2025)](https://pmc.ncbi.nlm.nih.gov/articles/PMC12164520/)\n\n---\n*Topic: Encyclopedia › Physical world and mathematics › Physics › Matter and radiation physics › Condensed matter physics › Crystal and structural condensed matter*\n\n*Initially written Sep 29, 2026 · Edited: Oct 15, 2026; Oct 25, 2026*\n\n*Copyright 2026 EdgeChat AI, a subsidiary of Biostate AI.*\n\nLicense: Edgepedia Community License 1.0, https://www.edgepedia.org/edgepedia/license\n",
 "same_as": [],
 "url": "https://www.edgepedia.org/3d-electron-diffraction",
 "markdown_url": "https://www.edgepedia.org/3d-electron-diffraction.md",
 "license": {
  "name": "Edgepedia Community License 1.0",
  "url": "https://www.edgepedia.org/edgepedia/license",
  "summary": "Free with credit, commercial use included. AI training is open to everyone. For other uses, organizations over USD 100M in revenue or 100M monthly users license separately.",
  "spdx": "LicenseRef-Edgepedia-Community-1.0"
 },
 "credit": "\"3D electron diffraction\", Edgepedia (EdgeChat), https://www.edgepedia.org/3d-electron-diffraction. Edgepedia Community License 1.0.",
 "credit_md": "\"[3D electron diffraction](https://www.edgepedia.org/3d-electron-diffraction)\", Edgepedia (EdgeChat), [https://www.edgepedia.org/3d-electron-diffraction](https://www.edgepedia.org/3d-electron-diffraction). [Edgepedia Community License 1.0](https://www.edgepedia.org/edgepedia/license).",
 "credit_html": "\"<a href=\"https://www.edgepedia.org/3d-electron-diffraction\">3D electron diffraction</a>\", Edgepedia (EdgeChat), <a href=\"https://www.edgepedia.org/3d-electron-diffraction\">https://www.edgepedia.org/3d-electron-diffraction</a>. <a href=\"https://www.edgepedia.org/edgepedia/license\">Edgepedia Community License 1.0</a>.",
 "speakable": "3D electron diffraction, including the MicroED and automated diffraction tomography techniques, is a crystallographic method that determines structures of nanocrystals too small for X-ray diffraction."
}
