{
 "id": "eph4g3nvjg",
 "slug": "analytical-chromatography",
 "title": "Analytical chromatography",
 "updated": "2026-09-30",
 "topic_path": [
  {
   "id": "physical",
   "label": "Physical world and mathematics",
   "api_url": "https://www.edgepedia.org/api/v1/topics/physical"
  },
  {
   "id": "physical.chemistry",
   "label": "Chemistry",
   "api_url": "https://www.edgepedia.org/api/v1/topics/physical.chemistry"
  },
  {
   "id": "physical.chemistry.methods",
   "label": "Chemical principles and methods",
   "api_url": "https://www.edgepedia.org/api/v1/topics/physical.chemistry.methods"
  },
  {
   "id": "physical.chemistry.methods.analytical-chemistry",
   "label": "Analytical chemistry",
   "api_url": "https://www.edgepedia.org/api/v1/topics/physical.chemistry.methods.analytical-chemistry"
  },
  {
   "id": "physical.chemistry.methods.chromatography",
   "label": "Chromatography",
   "api_url": "https://www.edgepedia.org/api/v1/topics/physical.chemistry.methods.chromatography"
  }
 ],
 "geo": [
  {
   "id": "geo.nongeo.t1800.physical.chemistry.methods.analytical-chemistry",
   "label": "Non-geographic · 1800 to 1945: Analytical chemistry",
   "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t1800.physical.chemistry.methods.analytical-chemistry",
   "path": [
    {
     "id": "geo.nongeo",
     "label": "Non-geographic",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo"
    },
    {
     "id": "geo.nongeo.t1800",
     "label": "Non-geographic · 1800 to 1945",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t1800"
    },
    {
     "id": "geo.nongeo.t1800.physical",
     "label": "Physical world and mathematics",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t1800.physical"
    },
    {
     "id": "geo.nongeo.t1800.physical.chemistry",
     "label": "Chemistry",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t1800.physical.chemistry"
    },
    {
     "id": "geo.nongeo.t1800.physical.chemistry.methods",
     "label": "Chemical principles and methods",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t1800.physical.chemistry.methods"
    },
    {
     "id": "geo.nongeo.t1800.physical.chemistry.methods.analytical-chemistry",
     "label": "Analytical chemistry",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t1800.physical.chemistry.methods.analytical-chemistry"
    }
   ]
  },
  {
   "id": "geo.nongeo.t1946.physical.chemistry.methods.chromatography",
   "label": "Non-geographic · 1946 to 2000: Chromatography",
   "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t1946.physical.chemistry.methods.chromatography",
   "path": [
    {
     "id": "geo.nongeo",
     "label": "Non-geographic",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo"
    },
    {
     "id": "geo.nongeo.t1946",
     "label": "Non-geographic · 1946 to 2000",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t1946"
    },
    {
     "id": "geo.nongeo.t1946.physical",
     "label": "Physical world and mathematics",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t1946.physical"
    },
    {
     "id": "geo.nongeo.t1946.physical.chemistry",
     "label": "Chemistry",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t1946.physical.chemistry"
    },
    {
     "id": "geo.nongeo.t1946.physical.chemistry.methods",
     "label": "Chemical principles and methods",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t1946.physical.chemistry.methods"
    },
    {
     "id": "geo.nongeo.t1946.physical.chemistry.methods.analytical-chemistry",
     "label": "Analytical chemistry",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t1946.physical.chemistry.methods.analytical-chemistry"
    },
    {
     "id": "geo.nongeo.t1946.physical.chemistry.methods.chromatography",
     "label": "Chromatography",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t1946.physical.chemistry.methods.chromatography"
    }
   ]
  }
 ],
 "excerpt": "Analytical chromatography is a family of separation techniques that identifies and quantifies the components of chemical mixtures, reading what is present and how much from a chromatogram.",
 "snippet": "Analytical chromatography is a family of separation techniques that identifies and quantifies the components of chemical mixtures, reading what is present and how much from a chromatogram.",
 "node": "physical.chemistry.methods.chromatography",
 "markdown": "# Analytical chromatography\n\nAnalytical chromatography is a family of separation techniques that identifies and quantifies the components of chemical mixtures by moving a sample in a mobile phase through a stationary phase. It differs from preparative chromatography, which aims to purify individual components rather than to measure them: in analytical work the goal is quantitative or qualitative information about one or several components of a sample. Qualitative information comes from retention times, quantitative information from peak size.<sup>[1](https://application.wiley-vch.de/books/sample/3527333746_c01.pdf)</sup> The output is a chromatogram, a plot of detector signal against time or volume, from which a practitioner reads both what is present and how much.<sup>[2](https://www.ncbi.nlm.nih.gov/books/NBK599545/)</sup>\n\n| Key fact | Detail | Source |\n|---|---|---|\n| What a chromatogram shows | Signal intensity versus time or volume; peak height tracks concentration, peak area gives the quantity eluted, and retention time is the interval from injection to the peak maximum | <sup>[2](https://www.ncbi.nlm.nih.gov/books/NBK599545/)</sup> |\n| Separation principle | Components separate by their differential affinities for the mobile and stationary phases | <sup>[2](https://www.ncbi.nlm.nih.gov/books/NBK599545/)</sup> |\n| Retention mechanisms | Adsorption, partition (including reversed-phase LC and HILIC), ion exchange, affinity, and size exclusion | <sup>[3](https://www.chromtech.net.au/pdf2/_HPLC%20Method%20Development%20Guide%20SPO-A%2074p.pdf)</sup> |\n| Resolution thresholds | Baseline separation reported at \\( R \\geq 1.4 \\) in one method-development guide; a monograph states \\( R = 1.5 \\) is desirable for quantitative analysis | <sup>[3](https://www.chromtech.net.au/pdf2/_HPLC%20Method%20Development%20Guide%20SPO-A%2074p.pdf)</sup>, <sup>[4](https://www.metrohm.com/content/dam/metrohm/shared/documents/monographs/81085077EN.pdf)</sup> |\n| Detection limits | Smallest detectable signal about 3× noise for qualitative work, about 10:1 for quantitative work; LOD calculated at 30% of LOQ | <sup>[3](https://www.chromtech.net.au/pdf2/_HPLC%20Method%20Development%20Guide%20SPO-A%2074p.pdf)</sup> |\n| UHPLC performance | Sub-2 µm particles in 25–100 cm capillary columns at 1,000–7,000 bar; 100,000–300,000 theoretical plates | <sup>[5](https://www.annualreviews.org/content/journals/10.1146/annurev.anchem.1.031207.113014)</sup> |\n| Solvent footprint | Major pharmaceutical companies run more than one thousand HPLC systems, each producing about 1 L of waste per day; preparative HPLC can exceed 5 L per minute | <sup>[6](https://pubs.rsc.org/en/content/articlehtml/2025/gc/d4gc04300f)</sup> |\n\n## How it works\n\nWhen a mixture and a mobile phase flow over a stationary phase, separation occurs based on the differential affinities of the components for the two phases.<sup>[2](https://www.ncbi.nlm.nih.gov/books/NBK599545/)</sup> A component that interacts strongly with the stationary phase spends more time immobilized and elutes later; a weakly retained component elutes earlier. HPLC retention mechanisms are classified as adsorption (reversible binding to the stationary phase, as in normal-phase separations of isomers), partition (including reversed-phase LC and HILIC), ion exchange, affinity, and size exclusion.<sup>[3](https://www.chromtech.net.au/pdf2/_HPLC%20Method%20Development%20Guide%20SPO-A%2074p.pdf)</sup>\n\nBand broadening is described by plate theory. The van Deemter equation relates plate height \\( H \\) to the mobile-phase linear velocity \\( u_{0} \\) as an H versus u curve.<sup>[7](https://ass-ets.org/docs/course/03-plate-height-theory/)</sup> Plate height is determined by dividing the column length \\( L \\) by the plate number \\( N \\).<sup>[8](https://www.agilent.com/cs/library/primers/Public/LC-Handbook-Complete-2.pdf)</sup>\n\n## How it is done\n\nThe standard workflow runs sample preparation (extraction, purification, derivatization, concentration), automated injection via an autosampler, separation, then detection and interpretation.<sup>[2](https://www.ncbi.nlm.nih.gov/books/NBK599545/)</sup> Method development in LC typically starts by combining gradient time \\( t_{G} \\) (or %B) with temperature, then changing solvent or column type if needed; it is usually prudent to select an initial pH (for example pH 2.5) and reserve pH changes for later optimization.<sup>[9](https://molnar-institute.com/fileadmin/user_upload/_2017_Dolan_Chapter14.pdf)</sup>\n\nQuantification is usually by calibration against standards. Most quantitative HPLC methods use external standards and a normal calibration curve without an internal standard, because fixed-volume loop injection is more precise than GC injection.<sup>[10](https://chem.libretexts.org/Courses/Bloomsburg_-_Commonwealth_University_of_Pennsylvania/Quantitative_Chemical_Analysis/12%3A_Chromatographic_and_Electrophoretic_Methods/12.09%3A_High-Performance_Liquid_Chromatography)</sup> Validation follows regulatory expectations: WHO guidance states that HPLC and GC methods should be suitable for their intended use, with acceptance criteria for parameters such as selectivity (resolution and/or peak-to-valley ratio) and sensitivity (signal-to-noise).<sup>[11](https://cdn.who.int/media/docs/default-source/medicines/norms-and-standards/guidelines/trs1025/trs1025-annex4.pdf?download=true&sfvrsn=53f56dbc_4)</sup>\n\n## Origin\n\nChromatographic adsorption analysis separates chlorophyll pigments from leaf extracts without chemical decomposition.<sup>[12](https://link.springer.com/article/10.1007/s10698-026-09572-6)</sup> He passed pigment solutions in ligroin through glass columns packed with powdered adsorbents such as calcium carbonate or alumina, testing more than a hundred materials, which produced visually distinct colored bands through differential adsorption.<sup>[12](https://link.springer.com/article/10.1007/s10698-026-09572-6)</sup><sup> • </sup><sup>[12](https://link.springer.com/article/10.1007/s10698-026-09572-6)</sup><sup> • </sup><sup>[2](https://www.ncbi.nlm.nih.gov/books/NBK599545/)</sup>\n\nLater milestones: HPLC was introduced at the end of the 1960s,<sup>[4](https://www.metrohm.com/content/dam/metrohm/shared/documents/monographs/81085077EN.pdf)</sup> apart from a 1969 exploratory study, the breakthrough in ultrahigh-pressure liquid chromatography came in 1997 with proof-of-concept research by James Jorgenson, and the Jorgenson group later demonstrated capillary UHPLC separations up to 7000 bar.<sup>[13](https://pmc.ncbi.nlm.nih.gov/articles/PMC10989561/)</sup><sup> • </sup><sup>[25](https://www.chromatographyonline.com/view/myths-ultrahigh-pressure-liquid-chromatography)</sup>\n\n## Variants\n\n**Gas chromatography (GC)** suits volatile, thermally stable, low-molecular-weight compounds such as residual solvents, with capillary columns largely replacing packed columns; standard detectors are flame ionization (FID) for carbon-containing compounds, electron capture (ECD) for halogenated compounds, flame photometric (FPD) for sulfur or phosphorus compounds, and nitrogen-phosphorus (NPD) for nitrogen or phosphorus compounds.<sup>[14](https://www.farm.ucl.ac.be/tpao/portail_stat/cours_stat/des_indu/validation/documents_valid/cmc3.pdf)</sup> HPLC is not limited to volatile analytes, so it covers a broader compound range, but capillary GC columns have more theoretical plates and can separate more complex mixtures.<sup>[10](https://chem.libretexts.org/Courses/Bloomsburg_-_Commonwealth_University_of_Pennsylvania/Quantitative_Chemical_Analysis/12%3A_Chromatographic_and_Electrophoretic_Methods/12.09%3A_High-Performance_Liquid_Chromatography)</sup>\n\n**UHPLC/UPLC** retains HPLC principles but uses sub-2 µm particles at high linear velocities and higher pressures, yielding large gains in resolution, sensitivity, and speed.<sup>[15](https://www.tandfonline.com/doi/abs/10.1081/JLC-200053046)</sup> The first commercial UHPLC instrument appeared in 2004 with a 1000 bar limit, more than doubling the 400 bar industry standard; commercial limits now reach 1500 bar.<sup>[13](https://pmc.ncbi.nlm.nih.gov/articles/PMC10989561/)</sup> Capillary UHPLC packs sub-2 µm particles into 25–100 cm columns run at 1,000–7,000 bar, reaching 100,000–300,000 plates with run times from a few minutes (isocratic) to a few hours (long gradients).<sup>[5](https://www.annualreviews.org/content/journals/10.1146/annurev.anchem.1.031207.113014)</sup>\n\n**Ion chromatography** dates to 1975, with ion exchange columns plus conductivity detection remaining the most important type.<sup>[4](https://www.metrohm.com/content/dam/metrohm/shared/documents/monographs/81085077EN.pdf)</sup> **Two-dimensional LC** implementations are classified as single heartcut (LC-LC), multiple heartcut (mLC-LC), selective comprehensive (sLC × LC), and full comprehensive (LC × LC).<sup>[16](https://pubs.acs.org/doi/full/10.1021/acs.analchem.6b03506)</sup> In GC, comprehensive GC × GC gained wide attention after the publication of a full-color 2D chromatogram of an oil sample.<sup>[17](https://www.sciencedirect.com/science/article/abs/pii/S0165993606000501)</sup> Detector pairing matters: UV detectors are the most commonly used in clinical laboratories, and mass spectrometry is a key UHPLC detection mode, with 2.1 mm i.d. columns eliminating the flow splitting needed at 1–3 mL/min in older HPLC-MS interfaces.<sup>[2](https://www.ncbi.nlm.nih.gov/books/NBK599545/)</sup><sup> • </sup><sup>[13](https://pmc.ncbi.nlm.nih.gov/articles/PMC10989561/)</sup>\n\n## Applications\n\nIn pharmaceutical quality, HPLC and GC methods are used for identification of materials and products, determination of assay and related substances, and in process and cleaning validation.<sup>[11](https://cdn.who.int/media/docs/default-source/medicines/norms-and-standards/guidelines/trs1025/trs1025-annex4.pdf?download=true&sfvrsn=53f56dbc_4)</sup> Clinical laboratories rely mainly on UV detection.<sup>[2](https://www.ncbi.nlm.nih.gov/books/NBK599545/)</sup> Full comprehensive LC × LC can show several hundred peaks in reasonable analysis time and is used for sample profiling and fingerprinting such as metabolomics and untargeted discovery.<sup>[16](https://pubs.acs.org/doi/full/10.1021/acs.analchem.6b03506)</sup> Machine-learning models now predict retention from molecular structure across TLC, column chromatography, GC, and HPLC; chirality-aware graph neural networks coupled with uncertainty quantification yield separation probabilities for HPLC enantioseparation, and embedding mechanistic constraints keeps the models interpretable.<sup>[18](https://pubs.acs.org/doi/abs/10.1021/acs.accounts.5c00677)</sup> A 2025 study in Analytical Chemistry by Alberto Marchetto and colleagues reports in silico HPLC method development via machine learning.<sup>[19](https://doi.org/10.1021/acs.analchem.4c03466)</sup>\n\n## Limitations and alternatives\n\n**Physical failure modes.** Dead volumes between injector and detector cause peak broadening and tailing; asymmetry is more pronounced for early-eluting peaks and tailing increases with flow, and column overloading is another failure mode.<sup>[4](https://www.metrohm.com/content/dam/metrohm/shared/documents/monographs/81085077EN.pdf)</sup> Method development and validation also face poor solubility and instability of active pharmaceutical ingredients, pKa-dependent ionization, mobile phase incompatibility, column degradation, pump or injector malfunctions, and peak shape distortions.<sup>[20](https://www.analchemres.org/article_235373.html)</sup>\n\n**Co-elution and matrix effects.** One-dimensional LC fails for very complex mixtures, such as the thousands of metabolites in biological samples, and for closely related species such as enantiomers and structural isomers.<sup>[16](https://pubs.acs.org/doi/full/10.1021/acs.analchem.6b03506)</sup> In LC-MS, co-eluting compounds can compete with or suppress the ionization of analytes,<sup>[21](https://analyticalsciencejournals.onlinelibrary.wiley.com/doi/10.1002/jssc.202300571)</sup> and in bioanalytical studies matrix effects, ion suppression, and analyte instability complicate accurate quantification.<sup>[20](https://www.analchemres.org/article_235373.html)</sup> UHPLC itself has a limit in peak capacity, which two-dimensional LC can overcome.<sup>[22](https://www.mdpi.com/1420-3049/25/13/3047)</sup> Comprehensive LC × LC is increasingly used for complex samples, but wider adoption is hampered by method development involving many interdependent experimental variables and conflicting analysis goals.<sup>[23](https://www.annualreviews.org/content/journals/10.1146/annurev-anchem-071524-090321)</sup>\n\n**Alternatives.** A weighted multi-criteria RGB comparison found HPLC significantly exceeds CZE silica in analytical performance (72.8% vs 50.5%), due to worse repeatability and sensitivity in electrophoresis, while CZE is better in eco-friendliness and safety (69.3% vs 52.0%), mainly because chromatography generates more waste from larger column diameters and total flow.<sup>[24](https://link.springer.com/article/10.1007/s10337-020-03933-9)</sup> On greenness, the analytical method greenness score (AMGS) is a measure, and greening without new hardware means faster separations, greener solvents or additives, or both.<sup>[6](https://pubs.rsc.org/en/content/articlehtml/2025/gc/d4gc04300f)</sup>\n\n## References\n\n1. [Basic HPLC Theory and Definitions (Wiley-VCH)](https://application.wiley-vch.de/books/sample/3527333746_c01.pdf)\n2. [Chromatography - StatPearls - NCBI Bookshelf](https://www.ncbi.nlm.nih.gov/books/NBK599545/)\n3. [A Practical Guide to HPLC (2023)](https://www.chromtech.net.au/pdf2/_HPLC%20Method%20Development%20Guide%20SPO-A%2074p.pdf)\n4. [HPLC monograph (Metrohm)](https://www.metrohm.com/content/dam/metrohm/shared/documents/monographs/81085077EN.pdf)\n5. [Capillary Liquid Chromatography at Ultrahigh Pressures (Annual Review of Analytical Chemistry)](https://www.annualreviews.org/content/journals/10.1146/annurev.anchem.1.031207.113014)\n6. [In silico modeling enables greener analytical and preparative chromatographic methods](https://pubs.rsc.org/en/content/articlehtml/2025/gc/d4gc04300f)\n7. [03. Plate-Height Theory - Analytical Separation Science (ASS-ETS)](https://ass-ets.org/docs/course/03-plate-height-theory/)\n8. [The LC Handbook (Agilent)](https://www.agilent.com/cs/library/primers/Public/LC-Handbook-Complete-2.pdf)\n9. [Method development in liquid chromatography (Dolan)](https://molnar-institute.com/fileadmin/user_upload/_2017_Dolan_Chapter14.pdf)\n10. [12.09: High-Performance Liquid Chromatography - Chemistry LibreTexts](https://chem.libretexts.org/Courses/Bloomsburg_-_Commonwealth_University_of_Pennsylvania/Quantitative_Chemical_Analysis/12%3A_Chromatographic_and_Electrophoretic_Methods/12.09%3A_High-Performance_Liquid_Chromatography)\n11. [WHO TRS 1025 Annex 4: guideline on chromatographic methods in pharmaceutical quality](https://cdn.who.int/media/docs/default-source/medicines/norms-and-standards/guidelines/trs1025/trs1025-annex4.pdf?download=true&sfvrsn=53f56dbc_4)\n12. [The first steps of chromatography: practice, paradigm, and scientific change in early twentieth-century chemistry](https://link.springer.com/article/10.1007/s10698-026-09572-6)\n13. [Advances in ultra-high-pressure and multi-dimensional liquid chromatography instrumentation and workflows](https://pmc.ncbi.nlm.nih.gov/articles/PMC10989561/)\n14. [Validation of Chromatographic Methods](https://www.farm.ucl.ac.be/tpao/portail_stat/cours_stat/des_indu/validation/documents_valid/cmc3.pdf)\n15. [UPLC™: An Introduction and Review (Journal of Liquid Chromatography & Related Technologies, Vol 28, No 7-8)](https://www.tandfonline.com/doi/abs/10.1081/JLC-200053046)\n16. [Two-Dimensional Liquid Chromatography: A State of the Art Tutorial (Analytical Chemistry)](https://pubs.acs.org/doi/full/10.1021/acs.analchem.6b03506)\n17. [Recent developments in comprehensive two-dimensional gas chromatography (GC × GC): I. Introduction and instrumental set-up](https://www.sciencedirect.com/science/article/abs/pii/S0165993606000501)\n18. [Automation and AI-Powered Prediction in Chromatographic Separation](https://pubs.acs.org/doi/abs/10.1021/acs.accounts.5c00677)\n19. [Alberto Marchetto and colleagues (2025). In Silico High-Performance Liquid Chromatography Method Development via Machine Learning. Analytical Chemistry.](https://doi.org/10.1021/acs.analchem.4c03466)\n20. [Advances, Challenges, and Practical Solutions in HPLC and LC–MS Method Development for Pharmaceutical and Biological Samples](https://www.analchemres.org/article_235373.html)\n21. [Matrix effects demystified: Strategies for resolving challenges in analytical separations of complex samples](https://analyticalsciencejournals.onlinelibrary.wiley.com/doi/10.1002/jssc.202300571)\n22. [Compensate for or Minimize Matrix Effects? Strategies for Overcoming Matrix Effects in Liquid Chromatography-Mass Spectrometry Technique: A Tutorial Review](https://www.mdpi.com/1420-3049/25/13/3047)\n23. [Advances in Online Comprehensive Two-Dimensional Liquid Chromatography Method Development](https://www.annualreviews.org/content/journals/10.1146/annurev-anchem-071524-090321)\n24. [Assessment and Comparison of the Overall Analytical Potential of Capillary Electrophoresis and High-Performance Liquid Chromatography Using the RGB Model: How Much Can We Find Out?](https://link.springer.com/article/10.1007/s10337-020-03933-9)\n25. [Myths ultrahigh pressure liquid chromatography (chromatographyonline.com)](https://www.chromatographyonline.com/view/myths-ultrahigh-pressure-liquid-chromatography)\n\n---\n*Topic: Encyclopedia › Physical world and mathematics › Chemistry › Chemical principles and methods › Analytical chemistry › Chromatography*\n\n*Initially written Sep 29, 2026 · Reviewed: Sep 30, 2026 · Edited: Sep 30, 2026 · Last review: Sep 30, 2026*\n\n*Copyright 2026 EdgeChat AI, a subsidiary of Biostate AI.*\n\nLicense: Edgepedia Community License 1.0, https://www.edgepedia.org/edgepedia/license\n",
 "same_as": [],
 "url": "https://www.edgepedia.org/analytical-chromatography",
 "markdown_url": "https://www.edgepedia.org/analytical-chromatography.md",
 "license": {
  "name": "Edgepedia Community License 1.0",
  "url": "https://www.edgepedia.org/edgepedia/license",
  "summary": "Free with credit, commercial use included. AI training is open to everyone. For other uses, organizations over USD 100M in revenue or 100M monthly users license separately.",
  "spdx": "LicenseRef-Edgepedia-Community-1.0"
 },
 "credit": "\"Analytical chromatography\", Edgepedia (EdgeChat), https://www.edgepedia.org/analytical-chromatography. Edgepedia Community License 1.0.",
 "credit_md": "\"[Analytical chromatography](https://www.edgepedia.org/analytical-chromatography)\", Edgepedia (EdgeChat), [https://www.edgepedia.org/analytical-chromatography](https://www.edgepedia.org/analytical-chromatography). [Edgepedia Community License 1.0](https://www.edgepedia.org/edgepedia/license).",
 "credit_html": "\"<a href=\"https://www.edgepedia.org/analytical-chromatography\">Analytical chromatography</a>\", Edgepedia (EdgeChat), <a href=\"https://www.edgepedia.org/analytical-chromatography\">https://www.edgepedia.org/analytical-chromatography</a>. <a href=\"https://www.edgepedia.org/edgepedia/license\">Edgepedia Community License 1.0</a>.",
 "speakable": "Analytical chromatography is a family of separation techniques that identifies and quantifies the components of chemical mixtures, reading what is present and how much from a chromatogram."
}
