{
 "id": "epewz4az2p",
 "slug": "annular-dark-field-scanning-transmission-electron-microscopy",
 "title": "Annular dark-field scanning transmission electron microscopy",
 "updated": "2026-10-25",
 "topic_path": [
  {
   "id": "physical",
   "label": "Physical world and mathematics",
   "api_url": "https://www.edgepedia.org/api/v1/topics/physical"
  },
  {
   "id": "physical.physics",
   "label": "Physics",
   "api_url": "https://www.edgepedia.org/api/v1/topics/physical.physics"
  },
  {
   "id": "physical.physics.practice",
   "label": "Physics methods, practice, and community",
   "api_url": "https://www.edgepedia.org/api/v1/topics/physical.physics.practice"
  },
  {
   "id": "physical.physics.practice.electron-microscopy-methods",
   "label": "Electron microscopy methods",
   "api_url": "https://www.edgepedia.org/api/v1/topics/physical.physics.practice.electron-microscopy-methods"
  }
 ],
 "geo": [
  {
   "id": "geo.nongeo.t1946.physical.physics.practice.electron-microscopy-methods",
   "label": "Non-geographic · 1946 to 2000: Electron microscopy methods",
   "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t1946.physical.physics.practice.electron-microscopy-methods",
   "path": [
    {
     "id": "geo.nongeo",
     "label": "Non-geographic",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo"
    },
    {
     "id": "geo.nongeo.t1946",
     "label": "Non-geographic · 1946 to 2000",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t1946"
    },
    {
     "id": "geo.nongeo.t1946.physical",
     "label": "Physical world and mathematics",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t1946.physical"
    },
    {
     "id": "geo.nongeo.t1946.physical.physics",
     "label": "Physics",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t1946.physical.physics"
    },
    {
     "id": "geo.nongeo.t1946.physical.physics.practice",
     "label": "Physics methods, practice, and community",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t1946.physical.physics.practice"
    },
    {
     "id": "geo.nongeo.t1946.physical.physics.practice.electron-microscopy-methods",
     "label": "Electron microscopy methods",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t1946.physical.physics.practice.electron-microscopy-methods"
    }
   ]
  }
 ],
 "excerpt": "Annular dark-field scanning transmission electron microscopy (ADF-STEM) is an electron microscopy mode in which an annular detector yields Z-contrast images sensitive to atomic number, used to image single heavy atoms, dopants, and catalysts.",
 "snippet": "Annular dark-field scanning transmission electron microscopy (ADF-STEM) is an electron microscopy mode in which an annular detector yields Z-contrast images sensitive to atomic number, used to image single heavy atoms, dopants, and catalysts.",
 "node": "physical.physics.practice.electron-microscopy-methods",
 "markdown": "# Annular dark-field scanning transmission electron microscopy\n\nAnnular dark-field scanning transmission electron microscopy (ADF-STEM) is a scanning transmission electron microscopy mode in which an annular detector collects electrons scattered to medium and high angles, producing images whose intensity follows a power law in the atomic number of the material being imaged. Because the detector ring excludes the unscattered beam and the Bragg-diffracted electrons, the image reads as a direct, incoherent map of columnar scattering power rather than an interference pattern, which makes it composition-sensitive and comparatively easy to interpret.<sup>[1](https://iopscience.iop.org/article/10.1088/2515-7639/ac1ab8/pdf)</sup><sup> • </sup><sup>[2](https://link.springer.com/article/10.1186/s40543-018-0142-4)</sup> The same angular selection discards most of the signal, so ADF images are intrinsically noisy, and the method's quantitative use depends on careful detector calibration.<sup>[3](https://www.nature.com/articles/srep12419)</sup>\n\n| Key fact | Value |\n|---|---|\n| Typical detector geometry | Inner radius 30–100 mrad, outer radius 100–200 mrad; angles above ~80 mrad collect mainly incoherent electrons<sup>[4](https://www.globalsino.com/EM/page4788.html)</sup> |\n| Composition scaling | Intensity follows a power law in atomic number, \\( Z^{\\alpha} \\), with \\( \\alpha \\) between 1 and 2 depending on the collected angular range<sup>[5](https://juser.fz-juelich.de/record/860615/files/s7.pdf)</sup> |\n| Signal fraction | The high-angle signal is typically about 10% of total scattering, so images are shot-noise limited<sup>[1](https://iopscience.iop.org/article/10.1088/2515-7639/ac1ab8/pdf)</sup> |\n| Probe size | Aberration-corrected instruments routinely form probes smaller than 0.1 nm, even below 100 keV; reported resolution reaches 40.5 pm<sup>[1](https://iopscience.iop.org/article/10.1088/2515-7639/ac1ab8/pdf)</sup><sup> • </sup><sup>[6](https://pmc.ncbi.nlm.nih.gov/articles/PMC8958084/)</sup> |\n| Elemental sensitivity | About \\( 10^{5} \\) to \\( 10^{6} \\) times higher than energy-dispersive X-ray spectroscopy<sup>[7](https://onlinelibrary.wiley.com/doi/10.1002/jemt.1060170209)</sup> |\n| Angle convention | Scattering angles scale inversely with beam energy, so detector geometry should be quoted via the scattering parameter \\( s \\)<sup>[1](https://iopscience.iop.org/article/10.1088/2515-7639/ac1ab8/pdf)</sup> |\n\n## How it works\n\nIn a classical picture, beam electrons passing close to an atomic nucleus are deflected to high angles by Rutherford-type scattering, with a cross section proportional to \\( Z^{2} \\) when the inner collection angle is large enough.<sup>[1](https://iopscience.iop.org/article/10.1088/2515-7639/ac1ab8/pdf)</sup> Screening of the nucleus by inner-shell electrons reduces the measured exponent below 2, and thermal diffuse scattering contributes at the largest angles. The result is an incoherent, direct image of columnar scattering power.<sup>[2](https://link.springer.com/article/10.1186/s40543-018-0142-4)</sup>\n\nComposition sensitivity is real but not a fixed power law. Experiments with size-selected Pd (Z = 46) and Au (Z = 79) clusters measured the exponent in \\( I \\sim Z^{\\alpha} \\) varying between 1.2 and 1.8 as the collection angle changed from 14 to 103 mrad.<sup>[8](https://journals.aps.org/prb/abstract/10.1103/PhysRevB.84.073408)</sup> Careful quantitative studies agree that a power-law description, though useful qualitatively, is not reliable for quantitative work: it can fail even for monolayer materials when the inner angle is too small for pure Rutherford scattering or when multiple scattering occurs even at heavy single atoms.<sup>[1](https://iopscience.iop.org/article/10.1088/2515-7639/ac1ab8/pdf)</sup> Quantitative experiments on graphene, MoS₂, and WS₂ monolayers at 80 kV showed the deviation becomes evident at small detection angles (\\( s_{\\mathrm{inner}} \\) < 1 Å⁻¹) and for elements with Z > 20, with two causes: the nonmonotonic Z dependence of the atomic radius and the dynamical diffraction of a single atom.<sup>[9](https://www.nature.com/articles/s41598-018-30941-5)</sup>\n\nDynamical diffraction also works in the method's favor. Channeling of the probe along atomic columns makes column intensities sensitive to the depth of an impurity atom, because deeper atoms channel a more focused probe and scatter to higher angles; this effect underpins three-dimensional dopant profiling.<sup>[3](https://www.nature.com/articles/srep12419)</sup>\n\n## How it is done\n\nOptimum high-angle ADF imaging on a TEM/STEM system requires a high maximum diffraction angle, a small minimum camera length, and a descanning facility so the scattered disk stays on the annular detector during scanning.<sup>[7](https://onlinelibrary.wiley.com/doi/10.1002/jemt.1060170209)</sup> Inner and outer detector angles must be measured precisely for each camera length if the data are to be compared with simulations.<sup>[10](https://iopscience.iop.org/article/10.1088/1757-899X/109/1/012008/pdf)</sup>\n\nQuantitative work additionally requires detector response uniformity, signal linearity with flux, an accurate detector map for normalization, and accounting for post-specimen aberration distortions.<sup>[1](https://iopscience.iop.org/article/10.1088/2515-7639/ac1ab8/pdf)</sup> Contrast is commonly normalized as \\( Q_{\\mathrm{ADF}} = I_{\\mathrm{ADF}} / I_{0} \\), the detector current divided by the incident probe current.<sup>[9](https://www.nature.com/articles/s41598-018-30941-5)</sup> Because total high-angle scattering is only around 10% of the primary beam, normalization needs a detector sensitivity scan equivalent to the full beam current, using dropped-gain or dropped-current methods.<sup>[10](https://iopscience.iop.org/article/10.1088/1757-899X/109/1/012008/pdf)</sup> Dose is a trade-off: excessive dose damages the sample, while too little dose degrades precision through shot noise; at fixed dose, integrated cross-sections always carry lower expected error than peak-intensity measurements.<sup>[10](https://iopscience.iop.org/article/10.1088/1757-899X/109/1/012008/pdf)</sup>\n\n## Origin\n\nA. V. Crewe, J. Wall and L. M. Welter reported a high-resolution scanning transmission electron microscope in 1968,<sup>[11](https://doi.org/10.1063/1.1656079)</sup> and in 1970 Crewe, Wall, and J. Langmore reported the visibility of single atoms,<sup>[12](https://doi.org/10.1126/science.168.3937.1338)</sup> work later described as the first demonstration that individual heavy atoms could be distinguished from lighter supports.<sup>[5](https://juser.fz-juelich.de/record/860615/files/s7.pdf)</sup> In 1978, M. M. J. Treacy, A. Howie and C. J. Wilson published Z-contrast imaging of platinum and palladium catalysts; these early \"Z contrast\" images were derived from a combination of signals and differ from the ADF images used today.<sup>[13](https://doi.org/10.1080/01418617808239255)</sup><sup> • </sup><sup>[1](https://iopscience.iop.org/article/10.1088/2515-7639/ac1ab8/pdf)</sup>\n\nThe modern form emerged from [S. J. Pennycook](https://www.edgepedia.org/stephen-j-pennycook)'s group: a new high-angle annular detector design with D. McMullan in 1983,<sup>[14](https://doi.org/10.1016/0304-3991%2883%2990012-8)</sup> direct dopant imaging in silicon with J. Narayan in 1984,<sup>[15](https://doi.org/10.1063/1.95229)</sup> elemental mapping with S. D. Berger and R. J. Culbertson in 1986,<sup>[16](https://doi.org/10.1111/j.1365-2818.1986.tb02804.x)</sup> chemically sensitive structure imaging with L. A. Boatner in 1988,<sup>[17](https://doi.org/10.1038/336565a0)</sup> and the incoherent imaging theory of crystals with D. Jesson in 1990.<sup>[18](https://doi.org/10.1103/physrevlett.64.938)</sup> In parallel, R. F. Loane, P. Xu and J. Silcox showed in 1992 that ADF STEM images of zone-axis crystals are incoherent,<sup>[19](https://doi.org/10.1016/0304-3991%2892%2990054-n)</sup> and Jesson and Pennycook treated incoherent imaging with coherently scattered electrons in 1993.<sup>[20](https://doi.org/10.1098/rspa.1993.0060)</sup> Treacy published a historical review of Z-contrast techniques in 2011 that distinguishes Crewe's original Z contrast from ADF imaging.<sup>[21](https://doi.org/10.1017/s1431927611012074)</sup>\n\n## Variants\n\n**HAADF** collects at angles larger than about 80 mrad, where the signal is dominated by incoherent scattering and contrast is strongly Z-dependent.<sup>[5](https://juser.fz-juelich.de/record/860615/files/s7.pdf)</sup> At lower inner angles the detector collects more coherent contribution, trading some composition sensitivity for signal. **Annular bright-field (ABF)** uses a similar optical geometry but places the annular detector within the illumination cone, in the bright-field region; it markedly improves the visibility of light columns such as oxygen and lithium, which are only weakly visible in HAADF.<sup>[1](https://iopscience.iop.org/article/10.1088/2515-7639/ac1ab8/pdf)</sup><sup> • </sup><sup>[22](https://www.sciencedirect.com/science/article/abs/pii/S0304399110001129)</sup><sup> • </sup><sup>[2](https://link.springer.com/article/10.1186/s40543-018-0142-4)</sup><sup> • </sup><sup>[27](https://pubmed.ncbi.nlm.nih.gov/20434265/)</sup> Published accounts disagree on ABF's origin: one review states ABF imaging was developed as an alternative to ADF, while another states it became popular in the aberration-corrected era.<sup>[1](https://iopscience.iop.org/article/10.1088/2515-7639/ac1ab8/pdf)</sup><sup> • </sup><sup>[2](https://link.springer.com/article/10.1186/s40543-018-0142-4)</sup>\n\n**Variable-angle HAADF** acquires images at two detector angular ranges (for example 60–390 and 47–306 mrad) and combines them statistically. A 2024 analysis formally connects ADF to 4D-STEM: by reciprocity the ADF detector is equivalent to incoherent illumination over a wide range of illumination angles, ADF imaging and ptychographic reconstruction show similar transfer functions at higher spatial frequencies, and the integrated center-of-mass technique's coherent transfer function is identical to the ADF optical transfer function.<sup>[3](https://www.nature.com/articles/srep12419)</sup><sup> • </sup><sup>[23](https://www.cpsjournals.cn/en/article/doi/10.1088/1674-1056/ad8554?viewType=HTML)</sup>\n\n## Applications\n\nADF-STEM has been used for catalyst studies since the technique's infancy, because Z-contrast allowed individual heavy atoms to be differentiated from lighter, even crystalline, supports well before atomic resolution was possible.<sup>[5](https://juser.fz-juelich.de/record/860615/files/s7.pdf)</sup> Small metallic nanoparticles for PEMFC catalysts remain a key application where quantitative ADF-STEM and EDX must overcome minute size and irradiation-damage limits.<sup>[5](https://juser.fz-juelich.de/record/860615/files/s7.pdf)</sup> Dopant imaging is another core use: variable-angle HAADF with two detector ranges raised the probability of determining the correct number of Gd dopants in SrTiO₃ to above 63% for all sixteen configurations, against 56% for a single detector, with depth positions about 17% more likely correct.<sup>[3](https://www.nature.com/articles/srep12419)</sup> The method also serves tomography, depth sectioning, defect analysis, and interfaces.<sup>[1](https://iopscience.iop.org/article/10.1088/2515-7639/ac1ab8/pdf)</sup>\n\nRecent developments extend these uses. Atom counting from a combination of two ADF STEM images reveals the number of atoms at each column and can build a three-dimensional atomic model from a single 2D image.<sup>[24](https://www.sciencedirect.com/science/article/abs/pii/S0304399123001766)</sup> Aberration correction allows atomic-sized probes even at 40 kV, minimizing knock-on damage in beam-sensitive materials.<sup>[2](https://link.springer.com/article/10.1186/s40543-018-0142-4)</sup>\n\n## Limitations and alternatives\n\n**Thickness and channeling.** Column intensity is not simply linear with sample thickness or detector angle range.<sup>[6](https://pmc.ncbi.nlm.nih.gov/articles/PMC8958084/)</sup> Multislice simulations including phonon scattering show no contrast reversals with thickness, unlike coherent TEM imaging, but the relationship is nonlinear.<sup>[25](https://link.springer.com/article/10.1557/PROC-332-361)</sup> In heavy atomic columns, channeling saturates the ADF intensity within a few nanometers of thickness, so the signal comes predominantly from atoms near the probe's focal plane.<sup>[1](https://iopscience.iop.org/article/10.1088/2515-7639/ac1ab8/pdf)</sup>\n\n**Tilt and contamination.** Sample tilts up to 15 mrad can still yield atomic-resolution images but cause ADF intensity losses of 25% or more. A tilt plateau, with cross-section nearly invariant to mis-tilt up to one probe convergence angle, can be designed through inner-angle choice.<sup>[10](https://iopscience.iop.org/article/10.1088/1757-899X/109/1/012008/pdf)</sup> Depth identification is further limited by detector noise, sample instability under the beam, contamination, and surface amorphous layers.<sup>[3](https://www.nature.com/articles/srep12419)</sup>\n\n**Compared with alternatives.** Coherent high-resolution TEM phase contrast is sensitive to light atoms but shows thickness contrast reversals that ADF avoids.<sup>[25](https://link.springer.com/article/10.1557/PROC-332-361)</sup> EDX and EELS identify elements directly but are far less efficient: HAADF sensitivity exceeds EDX by about \\( 10^{5} \\) to \\( 10^{6} \\) times.<sup>[7](https://onlinelibrary.wiley.com/doi/10.1002/jemt.1060170209)</sup> Low-voltage \"gentle\" STEM with ADF imaging and EELS at low primary energies extends the method to beam-sensitive materials.<sup>[26](https://doi.org/10.1016/j.ultramic.2010.02.007)</sup> Depth (optical) sectioning resolution increases quadratically with probe convergence angle while lateral resolution increases linearly; optical sectioning has not achieved atomic resolution.<sup>[2](https://link.springer.com/article/10.1186/s40543-018-0142-4)</sup>\n\n## References\n\n1. [Quantitative annular dark-field imaging in the scanning transmission electron microscope, a review](https://iopscience.iop.org/article/10.1088/2515-7639/ac1ab8/pdf)\n2. [Material structure, properties, and dynamics through scanning transmission electron microscopy (Journal of Analytical Science and Technology, 2018)](https://link.springer.com/article/10.1186/s40543-018-0142-4)\n3. [Variable-angle high-angle annular dark-field imaging: application to three-dimensional dopant atom profiling (Scientific Reports, 2015)](https://www.nature.com/articles/srep12419)\n4. [Incoherence/Rutherford (Elastic) Scattering/Thermal Diffuse (Quasi-Elastically) Scattering (TDS)/Z-Contrast in HAADF-STEM](https://www.globalsino.com/EM/page4788.html)\n5. [The Use of Annular Dark-Field Scanning Transmission Electron Microscopy for Quantitative Catalyst Characterisation](https://juser.fz-juelich.de/record/860615/files/s7.pdf)\n6. [Effects of Electron Microscope Parameters and Sample Thickness on High Angle Annular Dark Field Imaging](https://pmc.ncbi.nlm.nih.gov/articles/PMC8958084/)\n7. [High-Angle annular dark-field imaging on a TEM/STEM system (Otten, 1991)](https://onlinelibrary.wiley.com/doi/10.1002/jemt.1060170209)\n8. [Quantitative Z-contrast imaging in the scanning transmission electron microscope with size-selected clusters (Phys. Rev. B 84, 073408, 2011)](https://journals.aps.org/prb/abstract/10.1103/PhysRevB.84.073408)\n9. [Atomic number dependence of Z contrast in scanning transmission electron microscopy (Scientific Reports, 2018)](https://www.nature.com/articles/s41598-018-30941-5)\n10. [Quantitative ADF STEM: acquisition, analysis and interpretation (IOP Conf. Ser.)](https://iopscience.iop.org/article/10.1088/1757-899X/109/1/012008/pdf)\n11. [A. V. Crewe, J. Wall, L. M. Welter (1968). A High-Resolution Scanning Transmission Electron Microscope. Journal of Applied Physics.](https://doi.org/10.1063/1.1656079)\n12. [A. V. Crewe, J. Wall, J. Langmore (1970). Visibility of Single Atoms. Science.](https://doi.org/10.1126/science.168.3937.1338)\n13. [M. M. J. Treacy, A Howie, C. J. Wilson (1978). Z contrast of platinum and palladium catalysts. Philosophical magazine. A/Philosophical magazine. A. Physics of condensed matter. Structure, defects and mechanical properties.](https://doi.org/10.1080/01418617808239255)\n14. [A new high-angle annular detector for stem (Ultramicroscopy, 1983)](https://doi.org/10.1016/0304-3991%2883%2990012-8)\n15. [S. J. Pennycook, J. Narayan (1984). Direct imaging of dopant distributions in silicon by scanning transmission electron microscopy. Applied Physics Letters.](https://doi.org/10.1063/1.95229)\n16. [S. J. Pennycook, S. D. Berger, R. J. Culbertson (1986). Elemental mapping with elastically scattered electrons. Journal of Microscopy.](https://doi.org/10.1111/j.1365-2818.1986.tb02804.x)\n17. [S. J. Pennycook, L. A. Boatner (1988). Chemically sensitive structure-imaging with a scanning transmission electron microscope. Nature.](https://doi.org/10.1038/336565a0)\n18. [S. Pennycook, D. Jesson (1990). High-resolution incoherent imaging of crystals. Physical Review Letters.](https://doi.org/10.1103/physrevlett.64.938)\n19. [Incoherent imaging of zone axis crystals with ADF STEM (Ultramicroscopy, 1992)](https://doi.org/10.1016/0304-3991%2892%2990054-n)\n20. [D. E. Jesson, S. J. Pennycook (1993). Incoherent imaging of thin specimens using coherently scattered electrons. Proceedings of the Royal Society of London Series A Mathematical and Physical Sciences.](https://doi.org/10.1098/rspa.1993.0060)\n21. [Michael M.J. Treacy (2011). ZDependence of Electron Scattering by Single Atoms into Annular Dark-Field Detectors. Microscopy and Microanalysis.](https://doi.org/10.1017/s1431927611012074)\n22. [Dynamics of annular bright field imaging in scanning transmission electron microscopy (Ultramicroscopy)](https://www.sciencedirect.com/science/article/abs/pii/S0304399110001129)\n23. [Making the link between ADF and 4D STEM: Resolution, transfer and coherence (Chinese Physics B, 2024)](https://www.cpsjournals.cn/en/article/doi/10.1088/1674-1056/ad8554?viewType=HTML)\n24. [Atom counting from a combination of two ADF STEM images (Ultramicroscopy, 2023/2024)](https://www.sciencedirect.com/science/article/abs/pii/S0304399123001766)\n25. [Annular Dark Field Imaging in STEM (Hillyard & Silcox, MRS Proceedings, 1994)](https://link.springer.com/article/10.1557/PROC-332-361)\n26. [Ondrej L. Krivanek and colleagues (2010). Gentle STEM: ADF imaging and EELS at low primary energies. Ultramicroscopy.](https://doi.org/10.1016/j.ultramic.2010.02.007)\n27. [pubmed.ncbi.nlm.nih.gov](https://pubmed.ncbi.nlm.nih.gov/20434265/)\n\n---\n*Topic: Encyclopedia › Physical world and mathematics › Physics › Physics methods, practice, and community › Electron microscopy methods*\n\n*Initially written Sep 29, 2026 · Edited: Oct 15, 2026; Oct 21, 2026; Oct 25, 2026*\n\n*Copyright 2026 EdgeChat AI, a subsidiary of Biostate AI.*\n\nLicense: Edgepedia Community License 1.0, https://www.edgepedia.org/edgepedia/license\n",
 "same_as": [],
 "url": "https://www.edgepedia.org/annular-dark-field-scanning-transmission-electron-microscopy",
 "markdown_url": "https://www.edgepedia.org/annular-dark-field-scanning-transmission-electron-microscopy.md",
 "license": {
  "name": "Edgepedia Community License 1.0",
  "url": "https://www.edgepedia.org/edgepedia/license",
  "summary": "Free with credit, commercial use included. AI training is open to everyone. For other uses, organizations over USD 100M in revenue or 100M monthly users license separately.",
  "spdx": "LicenseRef-Edgepedia-Community-1.0"
 },
 "credit": "\"Annular dark-field scanning transmission electron microscopy\", Edgepedia (EdgeChat), https://www.edgepedia.org/annular-dark-field-scanning-transmission-electron-microscopy. Edgepedia Community License 1.0.",
 "credit_md": "\"[Annular dark-field scanning transmission electron microscopy](https://www.edgepedia.org/annular-dark-field-scanning-transmission-electron-microscopy)\", Edgepedia (EdgeChat), [https://www.edgepedia.org/annular-dark-field-scanning-transmission-electron-microscopy](https://www.edgepedia.org/annular-dark-field-scanning-transmission-electron-microscopy). [Edgepedia Community License 1.0](https://www.edgepedia.org/edgepedia/license).",
 "credit_html": "\"<a href=\"https://www.edgepedia.org/annular-dark-field-scanning-transmission-electron-microscopy\">Annular dark-field scanning transmission electron microscopy</a>\", Edgepedia (EdgeChat), <a href=\"https://www.edgepedia.org/annular-dark-field-scanning-transmission-electron-microscopy\">https://www.edgepedia.org/annular-dark-field-scanning-transmission-electron-microscopy</a>. <a href=\"https://www.edgepedia.org/edgepedia/license\">Edgepedia Community License 1.0</a>.",
 "speakable": "Annular dark-field scanning transmission electron microscopy is an electron microscopy mode in which an annular detector yields Z-contrast images sensitive to atomic number, used to image single heavy atoms, dopants, and catalysts."
}
