 "id": "eps35yxrp0",
 "slug": "cerebral-oximetry",
 "title": "Cerebral oximetry",
 "updated": "2026-10-15",
 "topic_path": [
  {
   "id": "life",
   "label": "Life and health",
   "api_url": "https://www.edgepedia.org/api/v1/topics/life"
  },
  {
   "id": "life.health",
   "label": "Human health and medicine",
   "api_url": "https://www.edgepedia.org/api/v1/topics/life.health"
  },
  {
   "id": "life.health.clinical",
   "label": "Clinical assessment and procedures",
   "api_url": "https://www.edgepedia.org/api/v1/topics/life.health.clinical"
  },
  {
   "id": "life.health.clinical.clinical-anesthesia",
   "label": "Anesthesiology and perioperative care",
   "api_url": "https://www.edgepedia.org/api/v1/topics/life.health.clinical.clinical-anesthesia"
  }
 ],
 "geo": [
  {
   "id": "geo.nongeo.t1946.life.health.clinical.clinical-anesthesia",
   "label": "Non-geographic · 1946 to 2000: Anesthesiology and perioperative care",
   "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t1946.life.health.clinical.clinical-anesthesia",
   "path": [
    {
     "id": "geo.nongeo",
     "label": "Non-geographic",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo"
    },
    {
     "id": "geo.nongeo.t1946",
     "label": "Non-geographic · 1946 to 2000",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t1946"
    },
    {
     "id": "geo.nongeo.t1946.life",
     "label": "Life and health",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t1946.life"
    },
    {
     "id": "geo.nongeo.t1946.life.health",
     "label": "Human health and medicine",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t1946.life.health"
    },
    {
     "id": "geo.nongeo.t1946.life.health.clinical",
     "label": "Clinical assessment and procedures",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t1946.life.health.clinical"
    },
    {
     "id": "geo.nongeo.t1946.life.health.clinical.clinical-anesthesia",
     "label": "Anesthesiology and perioperative care",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t1946.life.health.clinical.clinical-anesthesia"
    }
   ]
  }
 ],
 "excerpt": "Cerebral oximetry is a noninvasive optical method that measures regional oxygen saturation of brain tissue through the intact skull using near-infrared spectroscopy, used in surgery, critical care, and neonatology.",
 "snippet": "Cerebral oximetry is a noninvasive optical method that measures regional oxygen saturation of brain tissue through the intact skull using near-infrared spectroscopy, used in surgery, critical care, and neonatology.",
 "node": "life.health.clinical.clinical-anesthesia",
 "markdown": "# Cerebral oximetry\n\nCerebral oximetry is a noninvasive optical method that measures regional oxygen saturation (rSO2) of brain tissue through the intact skull, using near-infrared spectroscopy (NIRS), in surgery, critical care, and neonatology. Unlike pulse oximetry, which measures arterial saturation, it reports a venous-weighted mixed tissue saturation that responds to both oxygen delivery and oxygen consumption.\n\n| Key fact | Detail |\n|---|---|\n| What is measured | Venous-weighted tissue hemoglobin saturation, assumed roughly 25–30% arterial and 70–75% venous <sup>[1](https://resources.wfsahq.org/wp-content/uploads/Tutorial_538_Final.pdf)</sup> |\n| Light used | Near-infrared wavelengths, typically 700–870 nm, where oxy- and deoxyhemoglobin absorb differently <sup>[2](https://pmc.ncbi.nlm.nih.gov/articles/PMC4258229/)</sup> |\n| Typical values | Normal ScO2 commonly cited as 60–80%; desaturation often defined as a >20% drop from baseline or an absolute value <50% <sup>[1](https://resources.wfsahq.org/wp-content/uploads/Tutorial_538_Final.pdf)</sup> |\n| Accuracy | Not an absolute measurement; limits of agreement about 9%, versus 2–3% for pulse oximetry, and no FDA accuracy standards exist <sup>[3](https://journals.lww.com/anesthesia-analgesia/fulltext/2013/10000/factors_affecting_the_performance_of_5_cerebral.10.aspx)</sup> |\n| Signal depth | Photodetectors sit 2–4 cm from the light source; only 6–20% of absorbed light is absorbed by cortical gray matter <sup>[4](https://link.springer.com/article/10.1007/s10877-024-01146-1)</sup><sup> • </sup><sup>[2](https://pmc.ncbi.nlm.nih.gov/articles/PMC4258229/)</sup> |\n| Approved devices | Seven FDA-approved systems in the US as of 2021, including INVOS, FORE-SIGHT, EQUANOX, Masimo O3, and NIRO-200 NX <sup>[5](https://pmc.ncbi.nlm.nih.gov/articles/PMC8043988/)</sup> |\n| Outcome evidence | In adult cardiac surgery, monitoring is associated with less postoperative cognitive dysfunction (OR 0.15) but no significant reduction in delirium or stroke <sup>[6](https://www.ovid.com/jnls/aoca/fulltext/10.4103/aca.aca_149_21~the-use-of-cerebral-oximetry-in-cardiac-surgery-a-systematic)</sup> |\n\n## How it works\n\nNear-infrared light passes through skin, bone, and brain because biological tissue is relatively transparent in the 700–950 nm window, penetrating several centimeters.<sup>[7](https://pmc.ncbi.nlm.nih.gov/articles/PMC8466732/)</sup> Oxyhemoglobin and deoxyhemoglobin have distinct absorption spectra that are maximally separated near 700 and 850 nm, so at least two wavelengths are needed to separate the two chromophores; concentration changes are calculated from the Beer–Lambert relation, \\( [X] = \\Delta A / (L \\cdot \\varepsilon) \\).<sup>[2](https://pmc.ncbi.nlm.nih.gov/articles/PMC4258229/)</sup> Because tissue scatters light strongly, the simple law is replaced by the modified [Beer–Lambert law](https://www.edgepedia.org/beer-lambert-law), which adds a differential pathlength factor and a scattering term: \\( \\mathrm{OD}_{\\lambda} = \\varepsilon_{\\lambda} \\cdot L \\cdot c \\cdot \\mathrm{DPF} + \\mathrm{OD}_{R,\\lambda} \\).<sup>[4](https://link.springer.com/article/10.1007/s10877-024-01146-1)</sup>\n\nThe measured region contains arteries, capillaries, and veins, and the signal is predominantly venous: in validation against a weighted reference of \\( 0.25 \\cdot S_{\\mathrm{aO2}} + 0.75 \\cdot S_{\\mathrm{jO2}} \\), the venous contribution was 70–80%.<sup>[8](https://journals.lww.com/anesthesia-analgesia/fulltext/1996/02000/validation_in_volunteers_of_a_near_infrared.10.aspx)</sup> Manufacturers therefore assume a fixed arterial-to-venous ratio, 25:75 for INVOS and 30:70 for FORE-SIGHT, EQUANOX, and NIRO, although the true venous percentage can range from 33% to 84%.<sup>[4](https://link.springer.com/article/10.1007/s10877-024-01146-1)</sup><sup> • </sup><sup>[9](https://bmcanesthesiol.biomedcentral.com/counter/pdf/10.1186/s12871-016-0298-7.pdf)</sup> This is why rSO2 differs from pulse-oximeter saturation: it falls when either delivery drops or consumption rises, and it works without a pulse, for example during cardiopulmonary bypass.<sup>[2](https://pmc.ncbi.nlm.nih.gov/articles/PMC4258229/)</sup>\n\n## How it is done\n\nAdhesive sensors with a light source and two or more photodetectors are placed over the frontal cortex. The proximal detector samples superficial tissue and the distal detector a deeper field; subtracting the superficial signal from the deep signal removes part of the extracranial contribution.<sup>[4](https://link.springer.com/article/10.1007/s10877-024-01146-1)</sup> The monitor measures tissue roughly 2–3 cm below the sensor.<sup>[10](https://www.brighamandwomens.org/assets/BWH/pediatric-newborn-medicine/pdfs/nirs-cpg.pdf)</sup>\n\nBecause baseline values vary between subjects by about 10%, the reading is used as a trend rather than an absolute index.<sup>[2](https://pmc.ncbi.nlm.nih.gov/articles/PMC4258229/)</sup> A widely used intervention criterion is a reduction of >20% from baseline or an absolute value <50% <sup>[1](https://resources.wfsahq.org/wp-content/uploads/Tutorial_538_Final.pdf)</sup>, though trial definitions vary widely (10%, 20%, 25%, or any drop from baseline).<sup>[6](https://www.ovid.com/jnls/aoca/fulltext/10.4103/aca.aca_149_21~the-use-of-cerebral-oximetry-in-cardiac-surgery-a-systematic)</sup> When an alarm fires, practitioners work through a corrective algorithm: adjust mean arterial pressure, increase FiO2, normalize end-tidal CO2, and increase cardiac output.<sup>[6](https://www.ovid.com/jnls/aoca/fulltext/10.4103/aca.aca_149_21~the-use-of-cerebral-oximetry-in-cardiac-surgery-a-systematic)</sup> In neonatal practice, absolute CrSO2 <60% or a >20% fall from baseline triggers evaluation for anemia, hypoxia, hypotension, hyperinflation, and hypocarbia.<sup>[10](https://www.brighamandwomens.org/assets/BWH/pediatric-newborn-medicine/pdfs/nirs-cpg.pdf)</sup>\n\n## Origin\n\nFrans F. Jöbsis published the foundational NIRS paper in Science in 1977, showing that near-infrared transillumination of the intact brain could continuously monitor cellular oxygen sufficiency and hemoglobin oxygenation.<sup>[11](https://doi.org/10.1126/science.929199)</sup> In 1985, Jane E. Brazy, Darrell V. Lewis, Michael H. Mitnick, and Frans F. Jöbsis vander Vliet reported noninvasive cerebral oxygenation monitoring in preterm infants in [Pediatrics](https://www.edgepedia.org/pediatrics).<sup>[12](https://doi.org/10.1542/peds.75.2.217)</sup> In 1991, Patrick W. McCormick and colleagues published the two-wavelength, two-detector cerebral optical spectroscopy approach in Critical Care Medicine <sup>[13](https://doi.org/10.1097/00003246-199101000-00020)</sup>; that paper first validated a NIRS cerebral monitor, the INVOS 2910, against a mixed brain blood reference. In 1993, A. Villringer, J. Planck, C. Hock, L. Schleinkofer, and U. Dirnagl extended NIRS to detecting hemodynamic changes during brain activation in human adults.<sup>[14](https://doi.org/10.1016/0304-3940%2893%2990181-j)</sup>\n\n## Variants\n\nMost commercial monitors use continuous-wave light with spatially resolved (multidistance) spectroscopy, employed in the SenSmart, FORE-SIGHT, INVOS, Masimo O3, and NIRO series; frequency-domain and time-resolved spectroscopy are rarely used clinically.<sup>[1](https://resources.wfsahq.org/wp-content/uploads/Tutorial_538_Final.pdf)</sup> While continuous-wave instruments were long limited to relative changes, some now use multi-distance measurements and spatially resolved spectroscopy to report an estimated absolute tissue oxygen saturation, and time-resolved and frequency-domain methods can in principle yield absolute values but remain largely investigational.<sup>[7](https://pmc.ncbi.nlm.nih.gov/articles/PMC8466732/)</sup><sup> • </sup><sup>[24](https://www.frontiersin.org/journals/pediatrics/articles/10.3389/fped.2021.653676/full)</sup> First-generation FORE-SIGHT used four laser wavelengths (690, 780, 805, 850 nm) against INVOS's two LED wavelengths (730, 810 nm); FORE-SIGHT ELITE uses a five-wavelength LED (685, 730, 770, 805, 850 nm) with detectors at 5.0 cm and 1.5 cm.<sup>[15](https://d-nb.info/1130379450/34)</sup> An isobestic wavelength at 810 nm provides total hemoglobin, and tissue saturation is derived as the ratio of oxyhemoglobin to total hemoglobin.<sup>[5](https://pmc.ncbi.nlm.nih.gov/articles/PMC8043988/)</sup> Devices also differ in response speed and bias: in a hypoxia study of 10 volunteers, INVOS reached a 10% relative-decrease threshold on average 28 s earlier than EQUANOX and 43 s earlier than FORE-SIGHT.<sup>[9](https://bmcanesthesiol.biomedcentral.com/counter/pdf/10.1186/s12871-016-0298-7.pdf)</sup>\n\n## Applications\n\n[Cardiac surgery](https://www.edgepedia.org/cardiac-surgery): cerebral desaturation occurs in up to 64% of cardiac surgery patients <sup>[1](https://resources.wfsahq.org/wp-content/uploads/Tutorial_538_Final.pdf)</sup>, with reported prevalence of 26–74% depending on the definition used.<sup>[6](https://www.ovid.com/jnls/aoca/fulltext/10.4103/aca.aca_149_21~the-use-of-cerebral-oximetry-in-cardiac-surgery-a-systematic)</sup> Pooling 14 randomized trials (n = 2,033), oximetry-guided management was associated with lower postoperative cognitive dysfunction (OR 0.15, 95% CI 0.04–0.54, very low certainty) but no significant difference in delirium (OR 0.75) or stroke (OR 0.81).<sup>[6](https://www.ovid.com/jnls/aoca/fulltext/10.4103/aca.aca_149_21~the-use-of-cerebral-oximetry-in-cardiac-surgery-a-systematic)</sup> In carotid endarterectomy, a 20% drop after cross-clamping yielded pooled sensitivity 70.5% and specificity 92.4% against awake neurological monitoring.<sup>[1](https://resources.wfsahq.org/wp-content/uploads/Tutorial_538_Final.pdf)</sup>\n\nNeonatology: the SafeBoosC II randomized trial showed that NIRS-guided treatment reduced cerebral hypoxia without changing early biomarkers of brain injury <sup>[16](https://doi.org/10.1038/pr.2015.266)</sup>, and the SafeBoosC III trial found that oximetry-guided treatment in the first 72 hours did not reduce mortality or severe brain injury at 36 weeks' postmenstrual age in extremely preterm infants.<sup>[17](https://doi.org/10.1056/nejmoa2207554)</sup> The NIRTURE trial used a 65–90% cerebral oxygenation target for the first 5 days in infants under 28 weeks and reduced time outside target (P < .01) without significant differences in major morbidities before discharge.<sup>[18](https://jamanetwork.com/journals/jamanetworkopen/fullarticle/2844666)</sup> A 2025 [Bayesian meta-analysis](https://www.edgepedia.org/bayesian-meta-analysis) of two randomized trials (667 infants under 34 weeks) found a 4.5% increase in survival without cerebral injury with 93% probability of superiority for NIRS-guided resuscitation.<sup>[19](https://link.springer.com/article/10.1007/s00431-025-06138-0)</sup>\n\n[Cardiac arrest](https://www.edgepedia.org/cardiac-arrest): rSO2 can be measured without a pulse during CPR <sup>[20](https://ccforum.biomedcentral.com/articles/10.1186/cc12546)</sup>, correlates with end-tidal CO2 (r = 0.641) <sup>[21](https://www.mdpi.com/2077-0383/14/11/3747)</sup>, and initial post-ROSC rSO2 predicted favorable neurological outcome with AUC 0.789 in a 2025 study.<sup>[22](https://www.frontiersin.org/journals/medicine/articles/10.3389/fmed.2025.1590908/full)</sup>\n\n## Limitations and alternatives\n\nThe main limitation is extracerebral contamination. Simulation studies suggest only 6–20% of the light absorbed before reaching the detector is absorbed by cortical gray matter, with most attenuation in scalp and skull.<sup>[2](https://pmc.ncbi.nlm.nih.gov/articles/PMC4258229/)</sup> A systematic review of 34 in vivo studies found correlations with intracerebral references (|r| = 0.18–0.77) overlapping those with extracerebral references (|r| = 0.13–0.81), concluding there is no indisputable evidence that most of the signal originates intracerebrally.<sup>[23](https://mdpi-res.com/d_attachment/jcm/jcm-12-02776/article_deploy/jcm-12-02776-v2.pdf?version=1681264979)</sup> Bias is also negatively influenced by darker skin pigment and female sex, effects that population averaging does not correct.<sup>[5](https://pmc.ncbi.nlm.nih.gov/articles/PMC8043988/)</sup><sup> • </sup><sup>[3](https://journals.lww.com/anesthesia-analgesia/fulltext/2013/10000/factors_affecting_the_performance_of_5_cerebral.10.aspx)</sup> There is no gold standard for NIRS monitoring, no consensus on normal ranges or ischemic thresholds, and no FDA accuracy standards; with inter-individual variation around 20%, devices function as trend monitors.<sup>[7](https://pmc.ncbi.nlm.nih.gov/articles/PMC8466732/)</sup><sup> • </sup><sup>[3](https://journals.lww.com/anesthesia-analgesia/fulltext/2013/10000/factors_affecting_the_performance_of_5_cerebral.10.aspx)</sup> Sensor cost is roughly $200 per patient, and given the contradictory outcome data, routine use in all patients cannot be recommended.<sup>[2](https://pmc.ncbi.nlm.nih.gov/articles/PMC4258229/)</sup> In resuscitation medicine, the ILCOR consensus states there are insufficient data for a recommendation for or against routine NIRS use, and current AHA and ERC guidelines do not endorse cerebral oximetry during or after cardiac arrest or for routine neuroprognostication.<sup>[22](https://www.frontiersin.org/journals/medicine/articles/10.3389/fmed.2025.1590908/full)</sup>\n\nCompared with alternatives, cerebral oximetry is noninvasive and continuous but venous-weighted and depth-limited. Jugular venous oximetry samples a true venous compartment but is invasive; transcranial Doppler measures flow velocity rather than saturation; EEG-based monitoring (pEEG, cEEG/qEEG) measures electrical activity rather than oxygen delivery, and the 2024 I-PROTECT consensus standardizes the nomenclature of all these modalities side by side.<sup>[4](https://link.springer.com/article/10.1007/s10877-024-01146-1)</sup>\n\n## References\n\n1. [Cerebral Oximetry, An Introduction (WFSA Tutorial 538)](https://resources.wfsahq.org/wp-content/uploads/Tutorial_538_Final.pdf)\n2. [Cerebral and Tissue Oximetry](https://pmc.ncbi.nlm.nih.gov/articles/PMC4258229/)\n3. [Factors Affecting the Performance of 5 Cerebral Oximeters During Hypoxia in Healthy Volunteers](https://journals.lww.com/anesthesia-analgesia/fulltext/2013/10000/factors_affecting_the_performance_of_5_cerebral.10.aspx)\n4. [Non-invasive technology for brain monitoring: definition and meaning of the principal parameters for the I-PROTECT group](https://link.springer.com/article/10.1007/s10877-024-01146-1)\n5. [Clinical Applications of Near-Infrared Spectroscopy Monitoring in Cardiovascular Surgery](https://pmc.ncbi.nlm.nih.gov/articles/PMC8043988/)\n6. [The Use of Cerebral Oximetry in Cardiac Surgery: systematic review and meta-analysis](https://www.ovid.com/jnls/aoca/fulltext/10.4103/aca.aca_149_21~the-use-of-cerebral-oximetry-in-cardiac-surgery-a-systematic)\n7. [A Review of Monitoring Methods for Cerebral Blood Oxygen Saturation](https://pmc.ncbi.nlm.nih.gov/articles/PMC8466732/)\n8. [Validation in Volunteers of a Near-Infrared Spectroscope for Monitoring Brain Oxygenation In Vivo](https://journals.lww.com/anesthesia-analgesia/fulltext/1996/02000/validation_in_volunteers_of_a_near_infrared.10.aspx)\n9. [Detection of critical cerebral desaturation thresholds by three regional oximeters during hypoxia: a pilot study in healthy volunteers](https://bmcanesthesiol.biomedcentral.com/counter/pdf/10.1186/s12871-016-0298-7.pdf)\n10. [Brigham and Women's Hospital Pediatric Newborn Medicine Clinical Practice Guideline: NIRS](https://www.brighamandwomens.org/assets/BWH/pediatric-newborn-medicine/pdfs/nirs-cpg.pdf)\n11. [Frans F. Jöbsis (1977). Noninvasive, Infrared Monitoring of Cerebral and Myocardial Oxygen Sufficiency and Circulatory Parameters. Science.](https://doi.org/10.1126/science.929199)\n12. [Jane E. Brazy and colleagues (1985). Noninvasive Monitoring of Cerebral Oxygenation in Preterm Infants: Preliminary Observations. PEDIATRICS.](https://doi.org/10.1542/peds.75.2.217)\n13. [PATRICK W. MCCORMICK and colleagues (1991). Noninvasive cerebral optical spectroscopy for monitoring cerebral oxygen delivery and hemodynamics. Critical Care Medicine.](https://doi.org/10.1097/00003246-199101000-00020)\n14. [Near infrared spectroscopy (NIRS): A new tool to study hemodynamic changes during activation of brain function in human adults (Neuroscience Letters, 1993)](https://doi.org/10.1016/0304-3940%2893%2990181-j)\n15. [A validation method for near-infrared spectroscopy based tissue oximeters for cerebral and somatic tissue oxygen saturation measurements](https://d-nb.info/1130379450/34)\n16. [Anne M. Plomgaard and colleagues (2015). The SafeBoosC II randomized trial: treatment guided by near-infrared spectroscopy reduces cerebral hypoxia without changing early biomarkers of brain injury. Pediatric Research.](https://doi.org/10.1038/pr.2015.266)\n17. [Mathias L. Hansen and colleagues (2023). Cerebral Oximetry Monitoring in Extremely Preterm Infants. New England Journal of Medicine.](https://doi.org/10.1056/nejmoa2207554)\n18. [Cerebral Oximetry–Guided Treatment and Cerebral Oxygenation in Extremely Preterm Infants: The NIRTURE randomized clinical trial](https://jamanetwork.com/journals/jamanetworkopen/fullarticle/2844666)\n19. [Brain oxygenation monitoring during neonatal stabilization and resuscitation: systematic review and meta-analysis with Bayesian analysis](https://link.springer.com/article/10.1007/s00431-025-06138-0)\n20. [Feasibility of absolute cerebral tissue oxygen saturation during cardiopulmonary resuscitation](https://ccforum.biomedcentral.com/articles/10.1186/cc12546)\n21. [Correlation Between End-Tidal Carbon Dioxide and Regional Cerebral Oxygen Saturation During Cardiopulmonary Resuscitation](https://www.mdpi.com/2077-0383/14/11/3747)\n22. [Comprehensive pre- and in-hospital NIRS monitoring after ROSC predicts neurological outcome following OHCA](https://www.frontiersin.org/journals/medicine/articles/10.3389/fmed.2025.1590908/full)\n23. [The Influence of Extracerebral Tissue on Continuous Wave Near-Infrared Spectroscopy in Adults: A Systematic Review of In Vivo Studies](https://mdpi-res.com/d_attachment/jcm/jcm-12-02776/article_deploy/jcm-12-02776-v2.pdf?version=1681264979)\n24. [Frontiers, Role of Optical Neuromonitoring in Neonatal Encephalopathy—Current State and Recent Advances](https://www.frontiersin.org/journals/pediatrics/articles/10.3389/fped.2021.653676/full)\n\n---\n*Topic: Encyclopedia › Life and health › Human health and medicine › Clinical assessment and procedures › Anesthesiology and perioperative care*\n\n*Initially written Sep 29, 2026 · Edited: Oct 15, 2026*\n\n*Copyright 2026 EdgeChat AI, a subsidiary of Biostate AI.*\n\nLicense: Edgepedia Community License 1.0, https://www.edgepedia.org/edgepedia/license\n",
 "same_as": [],
 "url": "https://www.edgepedia.org/cerebral-oximetry",
 "markdown_url": "https://www.edgepedia.org/cerebral-oximetry.md",
 "license": {
  "name": "Edgepedia Community License 1.0",
  "url": "https://www.edgepedia.org/edgepedia/license",
  "summary": "Free with credit, commercial use included. AI training is open to everyone. For other uses, organizations over USD 100M in revenue or 100M monthly users license separately.",
  "spdx": "LicenseRef-Edgepedia-Community-1.0"
 },
 "credit": "\"Cerebral oximetry\", Edgepedia (EdgeChat), https://www.edgepedia.org/cerebral-oximetry. Edgepedia Community License 1.0.",
 "credit_md": "\"[Cerebral oximetry](https://www.edgepedia.org/cerebral-oximetry)\", Edgepedia (EdgeChat), [https://www.edgepedia.org/cerebral-oximetry](https://www.edgepedia.org/cerebral-oximetry). [Edgepedia Community License 1.0](https://www.edgepedia.org/edgepedia/license).",
 "credit_html": "\"<a href=\"https://www.edgepedia.org/cerebral-oximetry\">Cerebral oximetry</a>\", Edgepedia (EdgeChat), <a href=\"https://www.edgepedia.org/cerebral-oximetry\">https://www.edgepedia.org/cerebral-oximetry</a>. <a href=\"https://www.edgepedia.org/edgepedia/license\">Edgepedia Community License 1.0</a>.",
 "speakable": "Cerebral oximetry is a noninvasive optical method that measures regional oxygen saturation of brain tissue through the intact skull using near-infrared spectroscopy, used in surgery, critical care, and neonatology."
}