{
 "id": "ept69e3yqx",
 "slug": "coherent-raman-scattering",
 "title": "Coherent Raman scattering",
 "updated": "2026-09-30",
 "topic_path": [
  {
   "id": "physical",
   "label": "Physical world and mathematics",
   "api_url": "https://www.edgepedia.org/api/v1/topics/physical"
  },
  {
   "id": "physical.physics",
   "label": "Physics",
   "api_url": "https://www.edgepedia.org/api/v1/topics/physical.physics"
  },
  {
   "id": "physical.physics.matter-and-radiation",
   "label": "Matter and radiation physics",
   "api_url": "https://www.edgepedia.org/api/v1/topics/physical.physics.matter-and-radiation"
  },
  {
   "id": "physical.physics.matter-and-radiation.atomic-and-molecular",
   "label": "Atomic and molecular physics",
   "api_url": "https://www.edgepedia.org/api/v1/topics/physical.physics.matter-and-radiation.atomic-and-molecular"
  },
  {
   "id": "physical.physics.matter-and-radiation.atomic-and-molecular.molecular_physics",
   "label": "Molecular physics",
   "api_url": "https://www.edgepedia.org/api/v1/topics/physical.physics.matter-and-radiation.atomic-and-molecular.molecular_physics"
  },
  {
   "id": "physical.physics.matter-and-radiation.atomic-and-molecular.molecular_physics.vibrational_spectroscopy",
   "label": "Vibrational spectroscopy and molecular vibrations",
   "api_url": "https://www.edgepedia.org/api/v1/topics/physical.physics.matter-and-radiation.atomic-and-molecular.molecular_physics.vibrational_spectroscopy"
  }
 ],
 "geo": [
  {
   "id": "geo.nongeo.t1946.physical.physics.matter-and-radiation.atomic-and-molecular",
   "label": "Non-geographic · 1946 to 2000: Atomic and molecular physics",
   "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t1946.physical.physics.matter-and-radiation.atomic-and-molecular",
   "path": [
    {
     "id": "geo.nongeo",
     "label": "Non-geographic",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo"
    },
    {
     "id": "geo.nongeo.t1946",
     "label": "Non-geographic · 1946 to 2000",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t1946"
    },
    {
     "id": "geo.nongeo.t1946.physical",
     "label": "Physical world and mathematics",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t1946.physical"
    },
    {
     "id": "geo.nongeo.t1946.physical.physics",
     "label": "Physics",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t1946.physical.physics"
    },
    {
     "id": "geo.nongeo.t1946.physical.physics.matter-and-radiation",
     "label": "Matter and radiation physics",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t1946.physical.physics.matter-and-radiation"
    },
    {
     "id": "geo.nongeo.t1946.physical.physics.matter-and-radiation.atomic-and-molecular",
     "label": "Atomic and molecular physics",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t1946.physical.physics.matter-and-radiation.atomic-and-molecular"
    }
   ]
  }
 ],
 "excerpt": "Coherent Raman scattering (CRS) is a nonlinear optical technique in which pump and Stokes lasers coherently drive molecular vibrations, enabling fast, label-free chemical imaging of materials and biological tissue.",
 "snippet": "Coherent Raman scattering (CRS) is a nonlinear optical technique in which pump and Stokes lasers coherently drive molecular vibrations, enabling fast, label-free chemical imaging of materials and biological tissue.",
 "node": "physical.physics.matter-and-radiation.atomic-and-molecular.molecular_physics.vibrational_spectroscopy",
 "markdown": "# Coherent Raman scattering\n\nCoherent Raman scattering (CRS) is a nonlinear optical technique in which pump and Stokes laser beams coherently drive molecular vibrations to measure chemical composition without labels. When the difference between the two laser frequencies matches a molecular vibration, the molecules oscillate coherently and scatter light much more strongly than in spontaneous [Raman scattering](https://www.edgepedia.org/raman-scattering), enabling fast chemical imaging of materials and biological tissue. A third variant, coherent Stokes Raman scattering (CSRS), detects a red-shifted signal.\n\n| Key fact | Value |\n|---|---|\n| Basic signals | CSRS, SRG, SRL, and CARS, distinguished by detected frequency<sup>[1](https://www.chem.uci.edu/~potma/AlbaJBO14.pdf)</sup> |\n| Signal enhancement over spontaneous Raman | Millions of times, enabling fluorescence-like imaging speeds<sup>[2](https://beta.iopscience.iop.org/article/10.1088/2515-7647/abfd09)</sup> |\n| Typical spectral resolution | Below 10 cm⁻¹ (BCARS) to about 14.6 cm⁻¹ (hyperspectral SRS)<sup>[3](https://doi.org/10.1038/nphoton.2014.145)</sup><sup> • </sup><sup>[4](https://www.jove.com/t/63677/direct-comparison-hyperspectral-stimulated-raman-scattering-coherent)</sup> |\n| Imaging speed | Video rate (20 frames/s) for single-frequency CARS; 3.5 ms per pixel for broadband spectra<sup>[5](https://www.annualreviews.org/content/journals/10.1146/annurev-anchem-071015-041627)</sup> |\n| Sensitivity | Millimolar detection limits at microsecond dwell times (70 mM DMSO for CARS at 10 µs; 21 mM for SRS at 83 µs)<sup>[6](https://link.springer.com/article/10.1186/s43593-022-00038-8)</sup> |\n| Laser power at sample | Roughly milliwatt level, since only 10%–20% of source light reaches the sample<sup>[7](https://www.frontiersin.org/journals/physics/articles/10.3389/fphy.2020.598420/full)</sup> |\n| Main limitation of CARS | Nonresonant background from electronic (non-vibrational) response<sup>[8](https://pmc.ncbi.nlm.nih.gov/articles/PMC2642972/)</sup> |\n\n## How it works\n\nIn CARS, three laser fields at the pump frequency \\( \\omega_{p} \\), the Stokes frequency \\( \\omega_{s} \\), and a probe frequency \\( \\omega_{p}' \\) interact through the third-order nonlinear susceptibility. The induced polarization is \\( P^{(3)} = \\chi^{(3)} \\cdot E_{p} \\cdot E_{s}^{*} \\cdot E_{p}' \\), where \\( E_{p}' = E_{p} \\) in the common degenerate configuration, and it radiates a new field at the anti-Stokes frequency \\( \\omega_{as} = (\\omega_{p} - \\omega_{s}) + \\omega_{p}' \\).<sup>[8](https://pmc.ncbi.nlm.nih.gov/articles/PMC2642972/)</sup> When the beating frequency \\( \\omega_{p} - \\omega_{s} \\) matches a molecular vibration, all molecules in the focal volume oscillate coherently and the anti-Stokes signal is strongly enhanced.<sup>[8](https://pmc.ncbi.nlm.nih.gov/articles/PMC2642972/)</sup>\n\nEfficient signal generation also requires phase matching, expressed as \\( |k_{as} - (2k_{p} - k_{s})| L < \\pi \\), where \\( L \\) is the light–sample interaction length. Tight focusing with a high numerical aperture objective relaxes this requirement, which is what allows the collinear geometry used in modern microscopes.<sup>[8](https://pmc.ncbi.nlm.nih.gov/articles/PMC2642972/)</sup>\n\nThe same electronic response that generates the signal also generates a background: because CARS is a non-zero-background technique, the resonant signal must be detected against a nonresonant contribution from instantaneous electronic nonlinearities.<sup>[9](http://onlinelibrary.wiley.com/doi/10.1002/cphc.200700202/full)</sup> In SRS, by contrast, tuning \\( \\omega_{p} - \\omega_{s} \\) to a vibration produces a weak decrease in pump intensity, stimulated Raman loss (SRL), and a simultaneous increase in Stokes intensity, stimulated Raman gain (SRG). Since these signals appear at the incident beam frequencies themselves, optical modulation and demodulation are needed to extract them.<sup>[5](https://www.annualreviews.org/content/journals/10.1146/annurev-anchem-071015-041627)</sup> The SRS signal scales linearly with pump intensity, Stokes intensity, and molecular concentration, and the nonresonant four-wave-mixing background present in CARS does not contribute.<sup>[2](https://beta.iopscience.iop.org/article/10.1088/2515-7647/abfd09)</sup><sup> • </sup><sup>[10](https://link.springer.com/article/10.1007/s44352-025-00017-y)</sup>\n\n## How it is done\n\nA CRS microscope needs two pulsed laser trains at different frequencies, one tunable to the desired Raman shift, combined collinearly and focused through a water or oil immersion objective.<sup>[7](https://www.frontiersin.org/journals/physics/articles/10.3389/fphy.2020.598420/full)</sup> Most modern SRS microscopes use a dual-beam solid-state system in which an ultrafast oscillator pumps an OPO generating a tunable 700–1,300 nm pump beam, while part of the oscillator output near 1,045 nm serves as the Stokes beam.<sup>[11](https://www.frontiersin.org/journals/chemical-biology/articles/10.3389/fchbi.2026.1754307/full)</sup>\n\nPulse duration sets spectral resolution: a bandwidth-limited 100 fs pulse at 800 nm spans about 150 cm⁻¹, whereas many condensed-phase Raman lines are about 10 cm⁻¹ wide, so picosecond pulses of 1–10 ps, giving 1–10 cm⁻¹ linewidths, are preferred for single-frequency work.<sup>[1](https://www.chem.uci.edu/~potma/AlbaJBO14.pdf)</sup><sup> • </sup><sup>[7](https://www.frontiersin.org/journals/physics/articles/10.3389/fphy.2020.598420/full)</sup>\n\nDetection differs between the variants. CARS photons appear at new anti-Stokes frequencies and are collected in the forward (F-CARS) or backward (E-CARS) direction by a photomultiplier tube or avalanche photodiode after bandpass filtering.<sup>[7](https://www.frontiersin.org/journals/physics/articles/10.3389/fphy.2020.598420/full)</sup> SRS is detected with photodiodes, which tolerate high saturation energy, after an acousto-optic or electro-optic modulator modulates one beam at megahertz frequencies; a lock-in amplifier demodulates the SRL or SRG signal.<sup>[5](https://www.annualreviews.org/content/journals/10.1146/annurev-anchem-071015-041627)</sup>\n\n## Origin\n\nCARS was first observed in 1965, when R. W. Terhune, P. D. Maker, and C. M. Savage published *Measurements of Nonlinear Light Scattering* in *Physical Review Letters*, generating coherent anti-Stokes radiation outside a laser cavity.<sup>[12](https://doi.org/10.1103/physrevlett.14.681)</sup> The technique received its name and was developed as a combustion spectroscopy tool by R. F. Begley, A. B. Harvey, and R. L. Byer in *Applied Physics Letters* in 1974.<sup>[13](https://doi.org/10.1063/1.1655519)</sup> The first CARS microscope, with noncollinearly overlapped pump and Stokes beams focused on a single vibrational frequency, was reported by M. D. Duncan, J. Reintjes, and T. J. Manuccia in *Optics Letters* in 1982.<sup>[14](https://doi.org/10.1364/ol.7.000350)</sup>\n\nModern CARS microscopy dates to 1999, when Andreas Zumbusch, Gary R. Holtom, and X. Sunney Xie demonstrated three-dimensional vibrational imaging of living cells with a tightly focused ultrafast laser in a collinear geometry.<sup>[15](https://doi.org/10.1103/physrevlett.82.4142)</sup> Video-rate CARS chemical imaging of tissue in vivo followed in 2005 in work by Conor L. Evans, Eric O. Potma, and colleagues.<sup>[16](https://doi.org/10.1073/pnas.0508282102)</sup> SRS microscopy was developed after CARS microscopy, first with kilohertz-rate femtosecond lasers and then with high-repetition-rate sources that made real-time imaging practical and drove the wider adoption of CRS microscopy.<sup>[2](https://beta.iopscience.iop.org/article/10.1088/2515-7647/abfd09)</sup>\n\n## Variants\n\n**Background-suppressed CARS.** Many schemes target the nonresonant background: picosecond excitation with polarization control, epi-detected CARS, time-resolved CARS, interferometric CARS, frequency modulation, heterodyne CARS, and spectral phase retrieval.<sup>[5](https://www.annualreviews.org/content/journals/10.1146/annurev-anchem-071015-041627)</sup><sup> • </sup><sup>[2](https://beta.iopscience.iop.org/article/10.1088/2515-7647/abfd09)</sup>\n\n**Multiplex and broadband CARS.** Multiplex CARS setups used a narrowband 10 ps pump (1.5 cm⁻¹) and a broadband 80 fs Stokes (180 cm⁻¹) to cover about 200 cm⁻¹ in the C–H stretching region with sub-second acquisition.<sup>[17](https://re.public.polimi.it/bitstream/11311/1063423/2/LPR_Polli_submitted%20Version.pdf)</sup> Fourier-transform CARS microscopy was reported by Jennifer P. Ogilvie, Emmanuel Beaurepaire, Antigoni Alexandrou, and Manuel Joffre in *Optics Letters* in 2006.<sup>[18](https://doi.org/10.1364/ol.31.000480)</sup>\n\n**BCARS.** High-speed coherent Raman fingerprint imaging of biological tissues was reported by Charles H. Camp Jr. and colleagues in *Nature Photonics* in 2014.<sup>[3](https://doi.org/10.1038/nphoton.2014.145)</sup> Its three-color intrapulse excitation is about 100 times more efficient than two-color excitation in the fingerprint region, and heterodyne amplification by the nonresonant background raises the effective signal-to-noise ratio of weak peaks by over an order of magnitude.<sup>[3](https://doi.org/10.1038/nphoton.2014.145)</sup>\n\n**CSRS.** Laser-scanning coherent Stokes Raman scattering microscopy, which detects the red-shifted Stokes-side signal and suppresses fluorescence through lock-in demodulation, adds a third CRS microscopy variant alongside CARS and SRS.<sup>[19](https://www.nature.com/articles/s41467-023-38941-4)</sup>\n\n## Applications\n\nCRS is used wherever fast, label-free chemical contrast is needed. Lipid imaging is a prominent biological application: a single lipid bilayer containing about 10⁶ CH₂ oscillators yields roughly 0.1 detected CARS photon per shot under typical excitation, and lipid-droplet-rich samples support video-rate scanning above 20 frames per second.<sup>[1](https://www.chem.uci.edu/~potma/AlbaJBO14.pdf)</sup> [Broadband](https://www.edgepedia.org/broadband) coherent [Raman microspectroscopy](https://www.edgepedia.org/raman-microspectroscopy) is being advanced for spectral histopathology, for example in head and neck cancer, where simultaneous broadband CARS and broadband SRS imaging of tissue sections is combined with multichannel lock-in detection.<sup>[10](https://link.springer.com/article/10.1007/s44352-025-00017-y)</sup>\n\n## Limitations and alternatives\n\n**CARS limitations.** The nonresonant background is the main drawback of CARS: the signal must be detected against this electronic contribution, which limits sensitivity.<sup>[9](http://onlinelibrary.wiley.com/doi/10.1002/cphc.200700202/full)</sup><sup> • </sup><sup>[20](https://pubs.rsc.org/en/content/getauthorversionpdf/c5an00178a)</sup> The resonant CARS signal also decreases quadratically with molecular concentration, making low-concentration detection difficult.<sup>[8](https://pmc.ncbi.nlm.nih.gov/articles/PMC2642972/)</sup>\n\n**SRS comparison.** SRS avoids the nonresonant background, delivers undistorted Raman spectra, depends linearly on concentration, and operates under ambient light.<sup>[2](https://beta.iopscience.iop.org/article/10.1088/2515-7647/abfd09)</sup> On the same platform under identical excitation, however, a direct comparison found that CARS gives better spatial resolution while SRS gives better contrast and spectral resolution, with similar sensitivity; hyperspectral SRS reached 14.6 cm⁻¹ resolution on the 2,913 cm⁻¹ DMSO peak.<sup>[4](https://www.jove.com/t/63677/direct-comparison-hyperspectral-stimulated-raman-scattering-coherent)</sup> Multiplex SRS is free of nonresonant background but is limited by small bandwidths, pulse shaping rates, coarse spectral resolution, and competing nonlinear phenomena.<sup>[3](https://doi.org/10.1038/nphoton.2014.145)</sup>\n\n**Other alternatives.** Spontaneous Raman microscopy produces undistorted spectra but lacks the coherent enhancement, which for CRS reaches millions of times and makes [Raman imaging](https://www.edgepedia.org/raman-imaging) as fast as fluorescence microscopy.<sup>[2](https://beta.iopscience.iop.org/article/10.1088/2515-7647/abfd09)</sup> Published comparisons of CRS and infrared absorption microscopy exist; a review in Analyst concluded that CRS microscopies offer advantages with respect to FTIR imaging.<sup>[20](https://pubs.rsc.org/en/content/getauthorversionpdf/c5an00178a)</sup> Photodamage limits, by contrast, are sample- and condition-dependent, and no universal power threshold applies to CRS experiments.\n\n## References\n\n1. [Biological imaging with coherent Raman scattering microscopy: a tutorial](https://www.chem.uci.edu/~potma/AlbaJBO14.pdf)\n2. [Coherent Raman scattering microscopy for chemical imaging of biological systems](https://beta.iopscience.iop.org/article/10.1088/2515-7647/abfd09)\n3. [Charles H. Camp Jr and colleagues (2014). High-speed coherent Raman fingerprint imaging of biological tissues. Nature Photonics.](https://doi.org/10.1038/nphoton.2014.145)\n4. [Direct Comparison of Hyperspectral Stimulated Raman Scattering and Coherent Anti-Stokes Raman Scattering Microscopy for Chemical Imaging](https://www.jove.com/t/63677/direct-comparison-hyperspectral-stimulated-raman-scattering-coherent)\n5. [In Situ and In Vivo Molecular Analysis by Coherent Raman Scattering Microscopy](https://www.annualreviews.org/content/journals/10.1146/annurev-anchem-071015-041627)\n6. [Computational coherent Raman scattering imaging: breaking physical barriers by fusion of advanced instrumentation and data science](https://link.springer.com/article/10.1186/s43593-022-00038-8)\n7. [Coherent Anti-Stokes Raman Scattering Microscopy and Its Applications](https://www.frontiersin.org/journals/physics/articles/10.3389/fphy.2020.598420/full)\n8. [Coherent Anti-Stokes Raman Scattering Microscopy](https://pmc.ncbi.nlm.nih.gov/articles/PMC2642972/)\n9. [Coherent anti-Stokes Raman Scattering Microscopy (Müller, 2007, ChemPhysChem)](http://onlinelibrary.wiley.com/doi/10.1002/cphc.200700202/full)\n10. [Broadband coherent Raman microspectroscopy for the investigation of head and neck cancer advancing ultrafast spectral histopathology](https://link.springer.com/article/10.1007/s44352-025-00017-y)\n11. [Stimulated Raman scattering microscopy: fundamentals, instrumentation, and chemical imaging applications](https://www.frontiersin.org/journals/chemical-biology/articles/10.3389/fchbi.2026.1754307/full)\n12. [R. W. Terhune, P. D. Maker, C. M. Savage (1965). Measurements of Nonlinear Light Scattering. Physical Review Letters.](https://doi.org/10.1103/physrevlett.14.681)\n13. [R. F. Begley, A. B. Harvey, R. L. Byer (1974). Coherent anti-Stokes Raman spectroscopy. Applied Physics Letters.](https://doi.org/10.1063/1.1655519)\n14. [M. D. Duncan, J. Reintjes, T. J. Manuccia (1982). Scanning coherent anti-Stokes Raman microscope. Optics Letters.](https://doi.org/10.1364/ol.7.000350)\n15. [Andreas Zumbusch, Gary R. Holtom, X. Sunney Xie (1999). Three-Dimensional Vibrational Imaging by Coherent Anti-Stokes Raman Scattering. Physical Review Letters.](https://doi.org/10.1103/physrevlett.82.4142)\n16. [Conor L. Evans and colleagues (2005). Chemical imaging of tissue in vivo with video-rate coherent anti-Stokes Raman scattering microscopy. Proceedings of the National Academy of Sciences.](https://doi.org/10.1073/pnas.0508282102)\n17. [Broadband coherent Raman scattering microscopy](https://re.public.polimi.it/bitstream/11311/1063423/2/LPR_Polli_submitted%20Version.pdf)\n18. [Jennifer P. Ogilvie and colleagues (2006). Fourier-transform coherent anti-Stokes Raman scattering microscopy. Optics Letters.](https://doi.org/10.1364/ol.31.000480)\n19. [Coherent Stokes Raman scattering microscopy (CSRS)](https://www.nature.com/articles/s41467-023-38941-4)\n20. [Analyst review article on CARS microscopy (author version, RSC)](https://pubs.rsc.org/en/content/getauthorversionpdf/c5an00178a)\n\n---\n*Topic: Encyclopedia › Physical world and mathematics › Physics › Matter and radiation physics › Atomic and molecular physics › Molecular physics › Vibrational spectroscopy and molecular vibrations*\n\n*Initially written Sep 29, 2026 · Reviewed: Sep 30, 2026 · Edited: Sep 30, 2026 · Last review: Sep 30, 2026*\n\n*Copyright 2026 EdgeChat AI, a subsidiary of Biostate AI.*\n\nLicense: Edgepedia Community License 1.0, https://www.edgepedia.org/edgepedia/license\n",
 "same_as": [
  "https://www.chem.uci.edu/~potma/AlbaJBO14.pdf"
 ],
 "url": "https://www.edgepedia.org/coherent-raman-scattering",
 "markdown_url": "https://www.edgepedia.org/coherent-raman-scattering.md",
 "license": {
  "name": "Edgepedia Community License 1.0",
  "url": "https://www.edgepedia.org/edgepedia/license",
  "summary": "Free with credit, commercial use included. AI training is open to everyone. For other uses, organizations over USD 100M in revenue or 100M monthly users license separately.",
  "spdx": "LicenseRef-Edgepedia-Community-1.0"
 },
 "credit": "\"Coherent Raman scattering\", Edgepedia (EdgeChat), https://www.edgepedia.org/coherent-raman-scattering. Edgepedia Community License 1.0.",
 "credit_md": "\"[Coherent Raman scattering](https://www.edgepedia.org/coherent-raman-scattering)\", Edgepedia (EdgeChat), [https://www.edgepedia.org/coherent-raman-scattering](https://www.edgepedia.org/coherent-raman-scattering). [Edgepedia Community License 1.0](https://www.edgepedia.org/edgepedia/license).",
 "credit_html": "\"<a href=\"https://www.edgepedia.org/coherent-raman-scattering\">Coherent Raman scattering</a>\", Edgepedia (EdgeChat), <a href=\"https://www.edgepedia.org/coherent-raman-scattering\">https://www.edgepedia.org/coherent-raman-scattering</a>. <a href=\"https://www.edgepedia.org/edgepedia/license\">Edgepedia Community License 1.0</a>.",
 "speakable": "Coherent Raman scattering is a nonlinear optical technique in which pump and Stokes lasers coherently drive molecular vibrations, enabling fast, label-free chemical imaging of materials and biological tissue."
}
