{
 "id": "epbgv823hh",
 "slug": "ct-myocardial-perfusion-imaging",
 "title": "CT myocardial perfusion imaging",
 "updated": "2026-10-15",
 "topic_path": [
  {
   "id": "life",
   "label": "Life and health",
   "api_url": "https://www.edgepedia.org/api/v1/topics/life"
  },
  {
   "id": "life.health",
   "label": "Human health and medicine",
   "api_url": "https://www.edgepedia.org/api/v1/topics/life.health"
  },
  {
   "id": "life.health.clinical",
   "label": "Clinical assessment and procedures",
   "api_url": "https://www.edgepedia.org/api/v1/topics/life.health.clinical"
  },
  {
   "id": "life.health.clinical.clinical-imaging",
   "label": "Medical imaging and radiography",
   "api_url": "https://www.edgepedia.org/api/v1/topics/life.health.clinical.clinical-imaging"
  },
  {
   "id": "life.health.clinical.clinical-imaging.computed-tomography-techniques",
   "label": "Computed tomography techniques",
   "api_url": "https://www.edgepedia.org/api/v1/topics/life.health.clinical.clinical-imaging.computed-tomography-techniques"
  }
 ],
 "geo": [
  {
   "id": "geo.nongeo.t1946.life.health.clinical.clinical-imaging.computed-tomography-techniques",
   "label": "Non-geographic · 1946 to 2000: Computed tomography techniques",
   "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t1946.life.health.clinical.clinical-imaging.computed-tomography-techniques",
   "path": [
    {
     "id": "geo.nongeo",
     "label": "Non-geographic",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo"
    },
    {
     "id": "geo.nongeo.t1946",
     "label": "Non-geographic · 1946 to 2000",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t1946"
    },
    {
     "id": "geo.nongeo.t1946.life",
     "label": "Life and health",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t1946.life"
    },
    {
     "id": "geo.nongeo.t1946.life.health",
     "label": "Human health and medicine",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t1946.life.health"
    },
    {
     "id": "geo.nongeo.t1946.life.health.clinical",
     "label": "Clinical assessment and procedures",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t1946.life.health.clinical"
    },
    {
     "id": "geo.nongeo.t1946.life.health.clinical.clinical-imaging",
     "label": "Medical imaging and radiography",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t1946.life.health.clinical.clinical-imaging"
    },
    {
     "id": "geo.nongeo.t1946.life.health.clinical.clinical-imaging.computed-tomography-techniques",
     "label": "Computed tomography techniques",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t1946.life.health.clinical.clinical-imaging.computed-tomography-techniques"
    }
   ]
  },
  {
   "id": "geo.nongeo.t2001.life.health.clinical.clinical-imaging",
   "label": "Non-geographic · 2001 to 2020: Medical imaging and radiography",
   "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t2001.life.health.clinical.clinical-imaging",
   "path": [
    {
     "id": "geo.nongeo",
     "label": "Non-geographic",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo"
    },
    {
     "id": "geo.nongeo.t2001",
     "label": "Non-geographic · 2001 to 2020",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t2001"
    },
    {
     "id": "geo.nongeo.t2001.life",
     "label": "Life and health",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t2001.life"
    },
    {
     "id": "geo.nongeo.t2001.life.health",
     "label": "Human health and medicine",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t2001.life.health"
    },
    {
     "id": "geo.nongeo.t2001.life.health.clinical",
     "label": "Clinical assessment and procedures",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t2001.life.health.clinical"
    },
    {
     "id": "geo.nongeo.t2001.life.health.clinical.clinical-imaging",
     "label": "Medical imaging and radiography",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t2001.life.health.clinical.clinical-imaging"
    }
   ]
  }
 ],
 "excerpt": "CT myocardial perfusion imaging is a cardiac computed tomography technique that measures blood flow through the heart muscle during pharmacological stress to identify significant coronary stenoses.",
 "snippet": "CT myocardial perfusion imaging is a cardiac computed tomography technique that measures blood flow through the heart muscle during pharmacological stress to identify significant coronary stenoses.",
 "node": "life.health.clinical.clinical-imaging.computed-tomography-techniques",
 "markdown": "# CT myocardial perfusion imaging\n\nCT myocardial perfusion imaging (CTP) is a cardiac computed tomography technique that measures blood flow through the heart muscle, usually during pharmacological stress, to determine whether a coronary stenosis actually restricts perfusion. Iodinated contrast is tracked during its first pass through the myocardium, and perfusion defects appear as hypoattenuating areas containing reduced amounts of contrast material.<sup>[1](http://www.ajronline.org/doi/full/10.2214/AJR.14.13546)</sup> Published approaches divide into static CTP, itself split into single-energy and dual-energy techniques, and dynamic CTP.<sup>[2](https://www.sciencedirect.com/science/article/abs/pii/S0720048X16302340)</sup>\n\n| Key fact | Detail |\n|---|---|\n| Principle | First-pass distribution of iodinated contrast; ischemia appears as hypoattenuating myocardium<sup>[1](http://www.ajronline.org/doi/full/10.2214/AJR.14.13546)</sup> |\n| Quantitative output | Dynamic CTP yields myocardial blood flow (MBF) in mL/100 mL/min via deconvolution against an arterial input function<sup>[3](https://iris.unina.it/retrieve/870afc09-cf38-4e6b-be25-e27461b95157/how%20to%20perform%20ct%20perfusion.pdf)</sup> |\n| Stress agents | Adenosine 140 μg/kg/min infusion, or a single 0.4 mg regadenoson injection<sup>[1](http://www.ajronline.org/doi/full/10.2214/AJR.14.13546)</sup><sup> • </sup><sup>[4](https://pmc.ncbi.nlm.nih.gov/articles/PMC7297926/)</sup> |\n| Pooled accuracy (dynamic CTP) | Sensitivity 0.93 (95% CI 0.82–0.98), specificity 0.82 (95% CI 0.70–0.91) for ischemia<sup>[5](https://www.mdpi.com/2077-0383/12/22/7062)</sup> |\n| MBF thresholds | Reported ischemia cutoffs span 75–164 mL/100 mL/min depending on scanner and algorithm<sup>[6](https://www.frontiersin.org/journals/cardiovascular-medicine/articles/10.3389/fcvm.2024.1398635/full)</sup> |\n| Radiation dose | Dynamic perfusion CT: 9.2–12.5 mSv, reducible from 12.1 to 7.7 mSv with tube current modulation<sup>[7](https://pubs.rsna.org/doi/10.1148/radiol.13112739)</sup> |\n| Contrast dose | 60–120 mL for single-energy CT, reducible to about 50 mL with dual-energy or wide-coverage scanners<sup>[3](https://iris.unina.it/retrieve/870afc09-cf38-4e6b-be25-e27461b95157/how%20to%20perform%20ct%20perfusion.pdf)</sup> |\n\n## How it works\n\nAll CTP rests on first-pass contrast kinetics: a bolus of iodinated contrast is injected intravenously, and attenuation within the myocardium is measured as the bolus arrives and washes out. Regions supplied by a hemodynamically significant stenosis receive less contrast and appear hypoattenuating.<sup>[1](http://www.ajronline.org/doi/full/10.2214/AJR.14.13546)</sup>\n\nDynamic CTP makes this quantitative. Approximately 20–25 repeated CT scans sample myocardial attenuation at sequential time points, producing time–attenuation curves; these are coupled with an arterial input function measured in the ascending aorta using a hybrid deconvolution model, yielding MBF in mL/100 mL/min.<sup>[3](https://iris.unina.it/retrieve/870afc09-cf38-4e6b-be25-e27461b95157/how%20to%20perform%20ct%20perfusion.pdf)</sup>\n\nThe three technique families differ in output. Static CTP is a single ECG-gated, contrast-enhanced acquisition read visually or semi-quantitatively.<sup>[4](https://pmc.ncbi.nlm.nih.gov/articles/PMC7297926/)</sup> Dual-energy static CTP adds spectral information that improves first-pass perfusion assessment over single-energy CT.<sup>[8](https://pubs.rsna.org/doi/10.1148/radiol.13131183)</sup> Dynamic CTP visualizes the entire contrast in- and outflow, enabling direct quantification of perfusion.<sup>[4](https://pmc.ncbi.nlm.nih.gov/articles/PMC7297926/)</sup>\n\n## How it is done\n\nVasodilator stress is induced before acquisition. Adenosine is infused continuously at 140 μg/kg/min; one review specifies at least 2 minutes, aiming to raise heart rate 10–20 beats above resting, while another gives a 2–5 minute window at the same rate, so infusion duration varies between protocols.<sup>[1](http://www.ajronline.org/doi/full/10.2214/AJR.14.13546)</sup><sup> • </sup><sup>[4](https://pmc.ncbi.nlm.nih.gov/articles/PMC7297926/)</sup> Regadenoson, a selective A2A receptor agonist, is given as a single 0.4 mg injection and causes fewer systemic adverse effects, which benefits patients with asthma or COPD, but its longer effect requires a longer wait between stress and rest scans.<sup>[1](http://www.ajronline.org/doi/full/10.2214/AJR.14.13546)</sup><sup> • </sup><sup>[4](https://pmc.ncbi.nlm.nih.gov/articles/PMC7297926/)</sup> Beta blockers are generally avoided during stress CTP because they may affect ischemia identification.<sup>[9](https://cdt.amegroups.org/article/view/16957/html)</sup>\n\nFor static acquisition, the optimal time frame is 8–16 seconds after contrast enhancement in the aorta reaches 100 HU; optimal delays of 2–4 s have also been reported, depending on measurement location (ascending or descending aorta) and HU threshold (150 or 250 HU).<sup>[1](http://www.ajronline.org/doi/full/10.2214/AJR.14.13546)</sup><sup> • </sup><sup>[4](https://pmc.ncbi.nlm.nih.gov/articles/PMC7297926/)</sup> For dynamic acquisition, a timing bolus starts the scan 4–6 seconds before contrast arrives at the left ventricle or ascending aorta, then images are acquired every 1–3 seconds for 20–40 seconds.<sup>[9](https://cdt.amegroups.org/article/view/16957/html)</sup> Contrast bolus injection time should be 10 s or less, with a saline chaser of 40–50 mL.<sup>[3](https://iris.unina.it/retrieve/870afc09-cf38-4e6b-be25-e27461b95157/how%20to%20perform%20ct%20perfusion.pdf)</sup> Starting with the stress phase is preferred in patients with intermediate-to-high pre-test probability or moderate-to-high calcium scores, to optimize ischemia detection.<sup>[3](https://iris.unina.it/retrieve/870afc09-cf38-4e6b-be25-e27461b95157/how%20to%20perform%20ct%20perfusion.pdf)</sup>\n\n## Origin\n\nMyocardial perfusion CT grew out of electron beam CT, a scanner designed for stop-action imaging of the beating heart. Its electron beam rotation took 50–100 ms, fast enough for cardiac imaging at a time when conventional CT took 10 seconds per rotation. With ECG synchronization, sequential images could show the passage of contrast medium through the heart, which a historical review calls the birth of first-pass perfusion imaging.<sup>[10](https://www.ajronline.org/doi/10.2214/AJR.19.22681)</sup> Adenosine-stress myocardial perfusion CT was subsequently demonstrated with EBCT in an experimental dog model.<sup>[1](http://www.ajronline.org/doi/full/10.2214/AJR.14.13546)</sup> Dual-energy myocardial perfusion CT followed, and the dual-source dual-detector setup, operating two source-detector pairs at low (80–100 kV) and high (140 kV) tube voltages with about a 90° angular offset, became the most commonly used dual-energy technology.<sup>[1](http://www.ajronline.org/doi/full/10.2214/AJR.14.13546)</sup> Wide-detector and dual-source scanners later made dynamic CTP practical.<sup>[4](https://pmc.ncbi.nlm.nih.gov/articles/PMC7297926/)</sup>\n\n## Variants\n\n**Static single-energy CTP** produces one ECG-gated stress (and often rest) dataset interpreted for hypoattenuating defects; it is the simplest and lowest-dose option but gives no flow numbers.<sup>[4](https://pmc.ncbi.nlm.nih.gov/articles/PMC7297926/)</sup> **Static dual-energy CTP** uses vendor-specific implementations, most commonly dual-source dual-detector systems, and spectral separation of iodine improves perfusion assessment over single-energy acquisition.<sup>[1](http://www.ajronline.org/doi/full/10.2214/AJR.14.13546)</sup><sup> • </sup><sup>[8](https://pubs.rsna.org/doi/10.1148/radiol.13131183)</sup> **Dynamic CTP** acquires the full contrast passage and derives perfusion parameters including peak enhancement, time to peak (TTP), MBF, and myocardial blood volume (MBV) from time–activity curves.<sup>[11](https://www.mdpi.com/2308-3425/12/7/241)</sup> It requires wide-bore or high-pitch shuttle-mode scanners.<sup>[9](https://cdt.amegroups.org/article/view/16957/html)</sup>\n\n## Applications\n\nDynamic CTP is used to identify hemodynamically significant coronary stenoses and to quantify myocardial blood flow. Studies against MRI, SPECT, and invasive FFR reported sensitivity 76–100%, specificity 74–100%, PPV 48–100%, and NPV 82–100%, while a pooled analysis against MRI, SPECT, and PET gave sensitivity 0.93 (95% CI 0.82–0.98) and specificity 0.82 (95% CI 0.70–0.91).<sup>[5](https://www.mdpi.com/2077-0383/12/22/7062)</sup><sup> • </sup><sup>[9](https://cdt.amegroups.org/article/view/16957/html)</sup> Quantitative ischemia thresholds vary widely, with reported hyperaemic MBF cutoffs between 75 and 164 mL/100 mL/min depending on scanner and algorithm; one protocol paper uses 101 mL/100 g/min as the optimal cutoff for functionally significant CAD.<sup>[3](https://iris.unina.it/retrieve/870afc09-cf38-4e6b-be25-e27461b95157/how%20to%20perform%20ct%20perfusion.pdf)</sup><sup> • </sup><sup>[4](https://pmc.ncbi.nlm.nih.gov/articles/PMC7297926/)</sup><sup> • </sup><sup>[6](https://www.frontiersin.org/journals/cardiovascular-medicine/articles/10.3389/fcvm.2024.1398635/full)</sup> [Radiation](https://www.edgepedia.org/radiation) dose for dynamic perfusion CT has been reported as 9.2–12.5 mSv; automatic tube current modulation with 128-detector dual-source CT reduced it by one-third, from 12.1 mSv to 7.7 mSv.<sup>[7](https://pubs.rsna.org/doi/10.1148/radiol.13112739)</sup>\n\nRecent developments extend these uses. Photon-counting CT uses energy-resolving detectors that count incoming photons and measure photon energy, providing spectral information, improved contrast-to-noise ratio, and increased spatial resolution, and it has been applied to first-pass rest myocardial perfusion imaging with higher inter-reader agreement than dual-energy CT (\\( \\kappa = 0.86 \\) vs 0.62).<sup>[4](https://pmc.ncbi.nlm.nih.gov/articles/PMC7297926/)</sup><sup> • </sup><sup>[12](https://www.springermedizin.de/spectral-photon-counting-ct-in-first-pass-myocardial-perfusion-i/51468934)</sup> An automated quantitative CTP pipeline combining beam hardening correction, temporal registration, automated segmentation, and MBF estimation found an optimal stress MBF threshold for abnormal flow of 200 mL/min/100 g (95% CI 179.2–220.8), and territorial MBF differed between vessels with and without obstructive stenosis (165 ± 61 vs 274 ± 62 mL/min/100 g, \\( p < 0.05 \\)), extending CTP toward microvascular disease detection.<sup>[13](https://www.frontiersin.org/journals/cardiovascular-medicine/articles/10.3389/fcvm.2025.1621443/full)</sup> Real-world combined CCTA plus stress dynamic CTP protocols using regadenoson and shuttle acquisition have also been reported as feasible.<sup>[11](https://www.mdpi.com/2308-3425/12/7/241)</sup>\n\n## Limitations and alternatives\n\nThe most common artifact is beam hardening at the inferior base of the myocardium, where the highly attenuating spine and contrast-filled descending aorta sit between the tube and the heart, creating photon starvation that mimics hypoperfusion.<sup>[9](https://cdt.amegroups.org/article/view/16957/html)</sup> [Single-shot](https://www.edgepedia.org/single-shot) static acquisitions can miss the peak of contrast attenuation, and data collected across different cardiac cycles produce heterogeneous apicobasal attenuation; motion and partial scan artifacts also occur.<sup>[1](http://www.ajronline.org/doi/full/10.2214/AJR.14.13546)</sup> Scanners with small z-axis detector coverage produce banding artifacts from myocardial motion within the coverage zone, and longer acquisitions suffer variable contrast content from washout.<sup>[9](https://cdt.amegroups.org/article/view/16957/html)</sup>\n\nDynamic CTP's major limitations are high radiation exposure, inability to assess coronary morphology, and a required breath-hold of over 30 seconds.<sup>[1](http://www.ajronline.org/doi/full/10.2214/AJR.14.13546)</sup> Debate over diagnostic accuracy is partly driven by variability in the reference standards used (SPECT, MRI, PET, invasive angiography, FFR).<sup>[9](https://cdt.amegroups.org/article/view/16957/html)</sup> Stress perfusion cardiac MRI is the main alternative, showing 89% sensitivity and 80% specificity in CAD evaluation.<sup>[1](http://www.ajronline.org/doi/full/10.2214/AJR.14.13546)</sup> Against invasive FFR in 51 patients (96 vessels), computed FFR-CT reached per-vessel sensitivity, specificity, and accuracy of 81%, 85%, and 84% (AUC 0.89), versus 50%, 89%, and 75% for visual static CTP (AUC 0.70, \\( p < 0.001 \\)).<sup>[14](https://link.springer.com/article/10.1007/s10554-019-01658-x)</sup>\n\n## References\n\n1. [CT Myocardial Perfusion Imaging | AJR](http://www.ajronline.org/doi/full/10.2214/AJR.14.13546)\n2. [Dynamic CT myocardial perfusion imaging - ScienceDirect](https://www.sciencedirect.com/science/article/abs/pii/S0720048X16302340)\n3. [How to perform and evaluate a myocardial perfusion imaging by computed tomography](https://iris.unina.it/retrieve/870afc09-cf38-4e6b-be25-e27461b95157/how%20to%20perform%20ct%20perfusion.pdf)\n4. [Computed tomography for myocardial characterization in ischemic heart disease: a state-of-the-art review](https://pmc.ncbi.nlm.nih.gov/articles/PMC7297926/)\n5. [Dynamic CT Myocardial Perfusion: The Role of Functional Evaluation in the Diagnosis of Coronary Artery Disease](https://www.mdpi.com/2077-0383/12/22/7062)\n6. [Diagnostic efficacy of absolute and relative myocardial blood flow of stress dynamic CT myocardial perfusion for detecting myocardial ischemia in patients with hemodynamically significant coronary artery disease](https://www.frontiersin.org/journals/cardiovascular-medicine/articles/10.3389/fcvm.2024.1398635/full)\n7. [Stress Myocardial Perfusion: Imaging with Multidetector CT](https://pubs.rsna.org/doi/10.1148/radiol.13112739)\n8. [First–Arterial-Pass Dual-Energy CT for Assessment of Myocardial Blood Supply: Do We Need Rest, Stress, and Delayed Acquisition? Comparison with SPECT](https://pubs.rsna.org/doi/10.1148/radiol.13131183)\n9. [Myocardial computed tomography perfusion - Cardiovascular Diagnosis and Therapy](https://cdt.amegroups.org/article/view/16957/html)\n10. [Electron Beam CT: A Historical Review | AJR](https://www.ajronline.org/doi/10.2214/AJR.19.22681)\n11. [Feasibility, Added Value, and Radiation Dose of Combined Coronary CT Angiography and Stress Dynamic CT Myocardial Perfusion Imaging in Moderate Coronary Artery Disease: A Real-World Study](https://www.mdpi.com/2308-3425/12/7/241)\n12. [Spectral photon-counting CT in first-pass myocardial perfusion imaging for very high-risk patients: a comparison with dual-energy CT](https://www.springermedizin.de/spectral-photon-counting-ct-in-first-pass-myocardial-perfusion-i/51468934)\n13. [Quantitative cardiac CT perfusion: physiologically-inspired model and identifying microvascular disease from discordant CTA CAD-RADS](https://www.frontiersin.org/journals/cardiovascular-medicine/articles/10.3389/fcvm.2025.1621443/full)\n14. [Non-invasive CT-derived fractional flow reserve and static rest and stress CT myocardial perfusion imaging for detection of haemodynamically significant coronary stenosis](https://link.springer.com/article/10.1007/s10554-019-01658-x)\n\n---\n*Topic: Encyclopedia › Life and health › Human health and medicine › Clinical assessment and procedures › Medical imaging and radiography › Computed tomography techniques*\n\n*Initially written Sep 29, 2026 · Edited: Oct 15, 2026*\n\n*Copyright 2026 EdgeChat AI, a subsidiary of Biostate AI.*\n\nLicense: Edgepedia Community License 1.0, https://www.edgepedia.org/edgepedia/license\n",
 "same_as": [],
 "url": "https://www.edgepedia.org/ct-myocardial-perfusion-imaging",
 "markdown_url": "https://www.edgepedia.org/ct-myocardial-perfusion-imaging.md",
 "license": {
  "name": "Edgepedia Community License 1.0",
  "url": "https://www.edgepedia.org/edgepedia/license",
  "summary": "Free with credit, commercial use included. AI training is open to everyone. For other uses, organizations over USD 100M in revenue or 100M monthly users license separately.",
  "spdx": "LicenseRef-Edgepedia-Community-1.0"
 },
 "credit": "\"CT myocardial perfusion imaging\", Edgepedia (EdgeChat), https://www.edgepedia.org/ct-myocardial-perfusion-imaging. Edgepedia Community License 1.0.",
 "credit_md": "\"[CT myocardial perfusion imaging](https://www.edgepedia.org/ct-myocardial-perfusion-imaging)\", Edgepedia (EdgeChat), [https://www.edgepedia.org/ct-myocardial-perfusion-imaging](https://www.edgepedia.org/ct-myocardial-perfusion-imaging). [Edgepedia Community License 1.0](https://www.edgepedia.org/edgepedia/license).",
 "credit_html": "\"<a href=\"https://www.edgepedia.org/ct-myocardial-perfusion-imaging\">CT myocardial perfusion imaging</a>\", Edgepedia (EdgeChat), <a href=\"https://www.edgepedia.org/ct-myocardial-perfusion-imaging\">https://www.edgepedia.org/ct-myocardial-perfusion-imaging</a>. <a href=\"https://www.edgepedia.org/edgepedia/license\">Edgepedia Community License 1.0</a>.",
 "speakable": "CT myocardial perfusion imaging is a cardiac computed tomography technique that measures blood flow through the heart muscle during pharmacological stress to identify significant coronary stenoses."
}
