 "id": "epefm4ttks",
 "slug": "ion-trap-mass-spectrometry",
 "title": "Ion trap mass spectrometry",
 "updated": "2026-09-30",
 "topic_path": [
  {
   "id": "physical",
   "label": "Physical world and mathematics",
   "api_url": "https://www.edgepedia.org/api/v1/topics/physical"
  },
  {
   "id": "physical.chemistry",
   "label": "Chemistry",
   "api_url": "https://www.edgepedia.org/api/v1/topics/physical.chemistry"
  },
  {
   "id": "physical.chemistry.methods",
   "label": "Chemical principles and methods",
   "api_url": "https://www.edgepedia.org/api/v1/topics/physical.chemistry.methods"
  },
  {
   "id": "physical.chemistry.methods.analytical-chemistry",
   "label": "Analytical chemistry",
   "api_url": "https://www.edgepedia.org/api/v1/topics/physical.chemistry.methods.analytical-chemistry"
  },
  {
   "id": "physical.chemistry.methods.analytical-chemistry.mass-spectrometry-methods",
   "label": "Mass spectrometry methods",
   "api_url": "https://www.edgepedia.org/api/v1/topics/physical.chemistry.methods.analytical-chemistry.mass-spectrometry-methods"
  }
 ],
 "geo": [
  {
   "id": "geo.nongeo.t1946.physical.chemistry.methods.analytical-chemistry.mass-spectrometry-methods",
   "label": "Non-geographic · 1946 to 2000: Mass spectrometry methods",
   "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t1946.physical.chemistry.methods.analytical-chemistry.mass-spectrometry-methods",
   "path": [
    {
     "id": "geo.nongeo",
     "label": "Non-geographic",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo"
    },
    {
     "id": "geo.nongeo.t1946",
     "label": "Non-geographic · 1946 to 2000",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t1946"
    },
    {
     "id": "geo.nongeo.t1946.physical",
     "label": "Physical world and mathematics",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t1946.physical"
    },
    {
     "id": "geo.nongeo.t1946.physical.chemistry",
     "label": "Chemistry",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t1946.physical.chemistry"
    },
    {
     "id": "geo.nongeo.t1946.physical.chemistry.methods",
     "label": "Chemical principles and methods",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t1946.physical.chemistry.methods"
    },
    {
     "id": "geo.nongeo.t1946.physical.chemistry.methods.analytical-chemistry",
     "label": "Analytical chemistry",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t1946.physical.chemistry.methods.analytical-chemistry"
    },
    {
     "id": "geo.nongeo.t1946.physical.chemistry.methods.analytical-chemistry.mass-spectrometry-methods",
     "label": "Mass spectrometry methods",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t1946.physical.chemistry.methods.analytical-chemistry.mass-spectrometry-methods"
    }
   ]
  }
 ],
 "excerpt": "Ion trap mass spectrometry (IT-MS) is a mass spectrometry technique that stores ions in a radiofrequency quadrupole field, performing tandem MS in time up to MS10.",
 "snippet": "Ion trap mass spectrometry (IT-MS) is a mass spectrometry technique that stores ions in a radiofrequency quadrupole field, performing tandem MS in time up to MS10.",
 "node": "physical.chemistry.methods.analytical-chemistry.mass-spectrometry-methods",
 "markdown": "# Ion trap mass spectrometry\n\nIon trap mass spectrometry (IT-MS, also written ITMS) is a mass spectrometric technique in which ions are stored in a radiofrequency quadrupole electric field, then measured by their mass-to-charge ratio (m/z) and fragmented in sequential stages inside the same device. Because trapping, fragmentation, and mass analysis all occur in one cell, the method performs tandem MS in time (MSn, up to n = 10 in commercial instruments) rather than in space, and it delivers full-scan spectra and successive MS/MS stages from one ion population.<sup>[1](https://www.cigs.unimore.it/CigsDownloads/labs/lcmsit/IonTrap.pdf)</sup><sup> • </sup><sup>[2](https://mascot.ese.lbl.gov/mascot/help/ion_trap_main_help.html)</sup> The three-dimensional quadrupole ion trap is also known historically under the name QUISTOR.\n\n| Key fact | Value |\n|---|---|\n| Output | Full-scan mass spectra and sequential MSn spectra (n up to 10 commercially; MS12 demonstrated) <sup>[2](https://mascot.ese.lbl.gov/mascot/help/ion_trap_main_help.html)</sup><sup> • </sup><sup>[3](https://assets.thermofisher.com/TFS-Assets/CMD/Specification-Sheets/PS-62357-MS-LTQ-XL-PS62357-EN.pdf)</sup> |\n| Trapping principle | Mathieu-equation stability regions with parameters a and q; helium buffer gas cooling <sup>[2](https://mascot.ese.lbl.gov/mascot/help/ion_trap_main_help.html)</sup><sup> • </sup><sup>[4](https://www.pfeiffer-vacuum.com/global/en/knowledge/vacuum-technology/knowledge-book/6-mass-spectrometers-and-residual-gas-analysis/6_3_quadrupole_mass_spectrometers/)</sup> |\n| Buffer gas pressure | About 1 mtorr helium (\\( 10^{-3} \\) Torr) <sup>[2](https://mascot.ese.lbl.gov/mascot/help/ion_trap_main_help.html)</sup><sup> • </sup><sup>[1](https://www.cigs.unimore.it/CigsDownloads/labs/lcmsit/IonTrap.pdf)</sup> |\n| Ejection | Boundary ejection at \\( q_{z} = 0.908 \\), or resonance ejection at lower \\( q_{z} \\) (typically 0.83) <sup>[5](https://basinc.com/assets/library/issues/16-3/cs16-3c.pdf)</sup> |\n| Practical resolving power | Up to about 30,000 by slowing the scan <sup>[6](https://arpi.unipi.it/retrieve/ee6767ea-75e2-46b1-ada5-ea41a039cad3/2023_Review_LinearIonTrap_MassSpectromReview.pdf)</sup><sup> • </sup><sup>[1](https://www.cigs.unimore.it/CigsDownloads/labs/lcmsit/IonTrap.pdf)</sup> |\n| Ion capacity | Roughly \\( 10^{5} \\)-\\( 10^{6} \\) ions per 3D trap before space charge degrades performance <sup>[5](https://basinc.com/assets/library/issues/16-3/cs16-3c.pdf)</sup> |\n| Signature limitation | Low-mass cutoff: the lowest trapped fragment ion mass is approximately 0.3 times the precursor mass (dependent on \\( q_{z} \\)) <sup>[2](https://mascot.ese.lbl.gov/mascot/help/ion_trap_main_help.html)</sup> |\n\n## How it works\n\nIon motion in the quadrupole field obeys the Mathieu second-order differential equation, whose solutions define stable and unstable trajectories in a plane spanned by the dimensionless parameters a and q. For the radiofrequency-only trap the key parameter is qz = 4eV/(mr²ω²), where V is the rf amplitude, r the field radius, ω the angular frequency, and m the ion mass; a DC potential on the ring electrode adds an analogous parameter \\( a_{z} \\).<sup>[2](https://mascot.ese.lbl.gov/mascot/help/ion_trap_main_help.html)</sup> In the general quadrupole formulation, \\( a = \\frac{8 \\cdot Q \\cdot U}{m \\cdot r_{0}^{2} \\cdot \\omega^{2}} \\) and \\( q = \\frac{4 \\cdot Q \\cdot V}{m \\cdot r_{0}^{2} \\cdot \\omega^{2}} \\), combining the DC voltage U, rf amplitude V, field radius \\( r_{0} \\), angular frequency ω, and ion charge Q and mass m.<sup>[4](https://www.pfeiffer-vacuum.com/global/en/knowledge/vacuum-technology/knowledge-book/6-mass-spectrometers-and-residual-gas-analysis/6_3_quadrupole_mass_spectrometers/)</sup> Ions whose (a, q) coordinates fall inside the stability region oscillate within a pseudopotential well, with depths from about 1 eV near the origin to more than 10 eV near the beta-z = 1 boundary. The trap geometry satisfies \\( r_{0}^{2} = 2 \\cdot z_{0}^{2} \\), where \\( r_{0} \\) is the ring-electrode radius and \\( 2 \\cdot z_{0} \\) the end-cap separation.<sup>[1](https://www.cigs.unimore.it/CigsDownloads/labs/lcmsit/IonTrap.pdf)</sup>\n\n## How it is done\n\nA practical cycle runs as follows. Ions are generated (internally, or injected from an external source) into a trap filled with helium at about 1 mtorr; collisions with helium damp kinetic energy and focus trajectories toward the trap center, which is what makes trapping of injected ions possible.<sup>[2](https://mascot.ese.lbl.gov/mascot/help/ion_trap_main_help.html)</sup> For mass analysis, the rf amplitude V is ramped so each ion population moves along the \\( q_{z} \\) axis until it becomes unstable at the boundary \\( q_{z} = 0.908 \\) and is ejected axially through end-cap holes to a collision dynode and electron multiplier.<sup>[5](https://basinc.com/assets/library/issues/16-3/cs16-3c.pdf)</sup><sup> • </sup><sup>[2](https://mascot.ese.lbl.gov/mascot/help/ion_trap_main_help.html)</sup> [Resonance](https://www.edgepedia.org/resonance) ejection instead applies a supplementary rf voltage of (6-10)% of the rf amplitude on the endcaps, opening a \"hole\" in the stability region so ions eject at lower rf amplitude and the mass range extends; typical conditions give a maximum range of about 2000 Da/charge.<sup>[5](https://basinc.com/assets/library/issues/16-3/cs16-3c.pdf)</sup> For MSn, the precursor is isolated by ejecting all other ions, excited translationally by a supplementary end-cap voltage, fragmented by CID with helium, and rescanned; the cycle repeats for n stages.<sup>[5](https://basinc.com/assets/library/issues/16-3/cs16-3c.pdf)</sup> [Automatic gain control](https://www.edgepedia.org/automatic-gain-control) counts ions before filling the trap to avoid space charge, and stored waveform inverse [Fourier transform](https://www.edgepedia.org/fourier-transform) (SWIFT) waveforms provide general ion population control.<sup>[2](https://mascot.ese.lbl.gov/mascot/help/ion_trap_main_help.html)</sup><sup> • </sup><sup>[5](https://basinc.com/assets/library/issues/16-3/cs16-3c.pdf)</sup> In routine practice, resolving power up to about 30,000 is reached simply by lowering the scan speed, and scan times down to microseconds are possible because mass-selective ejection is very fast.<sup>[6](https://arpi.unipi.it/retrieve/ee6767ea-75e2-46b1-ada5-ea41a039cad3/2023_Review_LinearIonTrap_MassSpectromReview.pdf)</sup> By 1992, the mass range for mass-selective ejection exceeded 70,000 Da, a mass resolution of 1,130,000 had been achieved for a CsI cluster at m/z 3510 with the scan rate slowed by a factor of 333, and detection limits reached the attomole region.<sup>[1](https://www.cigs.unimore.it/CigsDownloads/labs/lcmsit/IonTrap.pdf)</sup>\n\n## Origin\n\nThe quadrupole ion trap remained a laboratory curiosity until a combined ion trap/quadrupole mass filter study led to the mass-selective axial instability method for recording spectra from the trap alone; in 1983 Finnigan announced the first commercial quadrupole ion trap instrument, as a detector for a gas chromatograph.<sup>[7](https://analyticalsciencejournals.onlinelibrary.wiley.com/doi/10.1002/mas.20250)</sup> The method was reported by G.C. Stafford and colleagues in 1984 in the International Journal of Mass Spectrometry and Ion Processes.<sup>[8](https://doi.org/10.1016/0168-1176%2884%2980077-4)</sup> Resonance ejection in the 3D trap was reported earlier, by J.E. Fulford and colleagues in 1980 in the Journal of Vacuum Science and Technology.<sup>[9](https://doi.org/10.1116/1.570570)</sup> Energy deposition in quadrupole ion-trap tandem MS was analyzed by J.N. Louris and colleagues in 1987 in Analytical Chemistry.<sup>[10](https://doi.org/10.1021/ac00140a021)</sup> In 1987, confinement of externally generated ions was demonstrated, and electrospray ionization was soon shown to be compatible with the trap.<sup>[7](https://analyticalsciencejournals.onlinelibrary.wiley.com/doi/10.1002/mas.20250)</sup><sup> • </sup><sup>[1](https://www.cigs.unimore.it/CigsDownloads/labs/lcmsit/IonTrap.pdf)</sup>\n\n## Variants\n\nThe 2D linear ion trap (LIT) confines ions radially between four rods rather than between ring and end-cap electrodes; it was reported by J.C. Schwartz, M.W. Senko, and J.E.P. Syka in 2002 in the Journal of the American Society for Mass Spectrometry.<sup>[11](https://doi.org/10.1016/s1044-0305%2802%2900384-7)</sup> J.W. Hager reported a linear trap with mass-selective axial ion ejection in 2002 in Rapid Communications in Mass Spectrometry, the basis of the QTRAP configuration, in which the LIT is filled in 1-500 ms, ions cool in 10-30 ms, and ejection occurs by fringe fields or by an auxiliary field on the rods.<sup>[12](https://doi.org/10.1002/rcm.607)</sup> The Q TRAP's scanning capabilities for high-sensitivity proteomics were reported by J.C.Y. Le Blanc and colleagues in 2003 in PROTEOMICS.<sup>[13](https://doi.org/10.1002/pmic.200300415)</sup> Other geometries include the rectilinear ion trap, reported by Z. Ouyang and colleagues in 2004 in Analytical Chemistry,<sup>[14](https://doi.org/10.1021/ac049420n)</sup> the digital ion trap with rectangular rf drive, reported by L. Ding and colleagues in 2004 in the Journal of Mass Spectrometry,<sup>[15](https://doi.org/10.1002/jms.637)</sup> and microfabricated trap arrays that operate multiplexed or collectively as a composite trap.<sup>[16](https://sage.cnpereading.com/doi/10.1255/ejms.832)</sup> A non-destructive variant measures the image current induced on an electrode embedded in the endcap, Fourier-analyzed into a spectrum, allowing remeasurement of the same ions.<sup>[5](https://basinc.com/assets/library/issues/16-3/cs16-3c.pdf)</sup> The Orbitrap, an electrostatic trap with image-current detection, was reported by A. Makarov in 2000 in Analytical Chemistry<sup>[17](https://doi.org/10.1021/ac991131p)</sup> and commercialized in hybrid with a linear ion trap front end, evaluated by A. Makarov and colleagues in 2006 in Analytical Chemistry.<sup>[18](https://doi.org/10.1021/ac0518811)</sup> Across more than 100,000 tandem spectra of identical peptide mixtures, the 2D LTQ identified 4-6-fold more peptides and proteins than the 3D LCQ Deca, and the 2D design offers about 15x higher ion capacity, up to 100% detection efficiency (versus about 50%), up to 70% trapping efficiency (versus about 5%), and a detection limit near 500 zmol (versus about 300 amol).<sup>[19](https://pmc.ncbi.nlm.nih.gov/articles/PMC1487187/)</sup>\n\n## Applications\n\nIon traps remain workhorses of proteomics, where LTQ, QTRAP, and newer quadrupole-LIT instruments run data-dependent, DIA, and PRM workflows; a 2025 study built targeted PRM assays from global DIA measurements without high mass accuracy and quantified consistently across three orders of magnitude from 1 ng of input.<sup>[20](https://www.nature.com/articles/s41467-025-58757-8)</sup> For targeted peptide analysis, parallel reaction monitoring (PRM) on a trap has a structural sensitivity advantage over selected reaction monitoring (SRM) because all product ions of a precursor accumulate in one acquisition event instead of serial dwell events with 1-2 ms switching overhead.<sup>[21](https://pmc.ncbi.nlm.nih.gov/articles/PMC11956834/)</sup> Miniaturization is a second active direction, reviewed for fieldable instruments by D.T. Snyder and colleagues in 2015 in Analytical Chemistry.<sup>[22](https://doi.org/10.1021/acs.analchem.5b03070)</sup> A 10 kg hand-held tandem mass spectrometer based on the rectilinear ion trap was built for air and water analysis with membrane sampling,<sup>[16](https://sage.cnpereading.com/doi/10.1255/ejms.832)</sup> and a PCB-based \"brick\" miniature analyzer multiplexes quadrupole mode with ion trap mode (up to 922 Th, tandem MS, 10 ppb LOD for imatinib).<sup>[23](https://www.mdpi.com/1420-3049/28/22/7640)</sup> The ion trap's historical role as a GC detector dates to Finnigan's 1983 announcement.<sup>[7](https://analyticalsciencejournals.onlinelibrary.wiley.com/doi/10.1002/mas.20250)</sup>\n\n## Limitations and alternatives\n\nThe main failure modes follow from the trapping physics. [Space charge](https://www.edgepedia.org/space-charge), the mutual coulombic interaction of stored ions, changes ion motion and degrades both mass resolution and dynamic range; AGC mitigates it by limiting the fill.<sup>[5](https://basinc.com/assets/library/issues/16-3/cs16-3c.pdf)</sup><sup> • </sup><sup>[2](https://mascot.ese.lbl.gov/mascot/help/ion_trap_main_help.html)</sup> Because trajectories become unstable at a fixed \\( q_{\\mathrm{eject}} \\) for a given rf amplitude, a well-defined low-mass cutoff arises: the lowest trapped fragment ion mass is approximately 0.3 times the precursor mass (dependent on \\( q_{z} \\)), so low-mass b- and y-ions can be missed in MS/MS.<sup>[2](https://mascot.ese.lbl.gov/mascot/help/ion_trap_main_help.html)</sup> Collisional activation inside the trap is inefficient in the high-q excitation mode (PQD), which avoids the low-mass cutoff but requires tuning and delivers low fragmentation efficiency.<sup>[3](https://assets.thermofisher.com/TFS-Assets/CMD/Specification-Sheets/PS-62357-MS-LTQ-XL-PS62357-EN.pdf)</sup> The pulsed nature of trap analysis limits intra-scan dynamic range to about 3 orders of magnitude.<sup>[21](https://pmc.ncbi.nlm.nih.gov/articles/PMC11956834/)</sup> The ion trap performs tandem MS in time, so it needs no additional analyzers, but it cannot run precursor-ion or neutral-loss scans, which require MS/MS in space on a triple quadrupole; the triple quadrupole in turn offers only single-stage MS/MS, with better control over ion kinetic energies.<sup>[6](https://arpi.unipi.it/retrieve/ee6767ea-75e2-46b1-ada5-ea41a039cad3/2023_Review_LinearIonTrap_MassSpectromReview.pdf)</sup><sup> • </sup><sup>[5](https://basinc.com/assets/library/issues/16-3/cs16-3c.pdf)</sup> Against high-resolution analyzers, the trade-off is accuracy versus practicality: Orbitrap resolving powers above 500,000 on a chromatographic time scale far exceed standard ion traps,<sup>[24](https://analyticalsciencejournals.onlinelibrary.wiley.com/doi/10.1002/mas.21549)</sup> but LITs operate at \\( 10^{-3} \\) mTorr versus \\( 10^{-10} \\) mTorr for Orbitrap analyzers, so their vacuum requirements and footprints are simpler and smaller. At low input (≤10 ng), a Q-LIT outperformed an Orbitrap in protein identifications, while the Orbitrap equaled or outperformed it at ≥50 ng.<sup>[20](https://www.nature.com/articles/s41467-025-58757-8)</sup> Where precursor-ion and neutral-loss scans, unit-mass quantitative SRM, or sub-ppm mass accuracy are required, triple quadrupoles and Orbitrap or Q-TOF analyzers are the corresponding alternatives.<sup>[6](https://arpi.unipi.it/retrieve/ee6767ea-75e2-46b1-ada5-ea41a039cad3/2023_Review_LinearIonTrap_MassSpectromReview.pdf)</sup><sup> • </sup><sup>[24](https://analyticalsciencejournals.onlinelibrary.wiley.com/doi/10.1002/mas.21549)</sup>\n\n## References\n\n1. [Ion trap mass spectrometry (March, Int J Mass Spectrom Ion Processes, 1992; PDF copy)](https://www.cigs.unimore.it/CigsDownloads/labs/lcmsit/IonTrap.pdf)\n2. [Matrix Science Help: Quadrupole Ion Trap MS](https://mascot.ese.lbl.gov/mascot/help/ion_trap_main_help.html)\n3. [LTQ XL Linear Ion Trap Mass Spectrometer – Product Specifications (Thermo Fisher Scientific)](https://assets.thermofisher.com/TFS-Assets/CMD/Specification-Sheets/PS-62357-MS-LTQ-XL-PS62357-EN.pdf)\n4. [Quadrupole Mass Spectrometers (QMS), Pfeiffer Know-How](https://www.pfeiffer-vacuum.com/global/en/knowledge/vacuum-technology/knowledge-book/6-mass-spectrometers-and-residual-gas-analysis/6_3_quadrupole_mass_spectrometers/)\n5. [Ion Trap Mass Spectrometry (Current Separations, Finnigan house journal)](https://basinc.com/assets/library/issues/16-3/cs16-3c.pdf)\n6. [Review of linear ion trap and QTrap mass spectrometry (2023, university repository copy)](https://arpi.unipi.it/retrieve/ee6767ea-75e2-46b1-ada5-ea41a039cad3/2023_Review_LinearIonTrap_MassSpectromReview.pdf)\n7. [Quadrupole ion traps (Mass Spectrometry Reviews, 2009)](https://analyticalsciencejournals.onlinelibrary.wiley.com/doi/10.1002/mas.20250)\n8. [Recent improvements in and analytical applications of advanced ion trap technology (International Journal of Mass Spectrometry and Ion Processes, 1984)](https://doi.org/10.1016/0168-1176%2884%2980077-4)\n9. [John Edward Fulford and colleagues (1980). Radio-frequency mass selective excitation and resonant ejection of ions in a three-dimensional quadrupole ion trap. Journal of Vacuum Science and Technology.](https://doi.org/10.1116/1.570570)\n10. [John N. Louris and colleagues (1987). Instrumentation, applications, and energy deposition in quadrupole ion-trap tandem mass spectrometry. Analytical Chemistry.](https://doi.org/10.1021/ac00140a021)\n11. [A two-dimensional quadrupole ion trap mass spectrometer (Journal of the American Society for Mass Spectrometry, 2002)](https://doi.org/10.1016/s1044-0305%2802%2900384-7)\n12. [James W. Hager (2002). A new linear ion trap mass spectrometer. Rapid Communications in Mass Spectrometry.](https://doi.org/10.1002/rcm.607)\n13. [J. C. Yves Le Blanc and colleagues (2003). Unique scanning capabilities of a new hybrid linear ion trap mass spectrometer (Q TRAP) used for high sensitivity proteomics applications. PROTEOMICS.](https://doi.org/10.1002/pmic.200300415)\n14. [Zheng Ouyang and colleagues (2004). Rectilinear Ion Trap: Concepts, Calculations, and Analytical Performance of a New Mass Analyzer. Analytical Chemistry.](https://doi.org/10.1021/ac049420n)\n15. [Li Ding and colleagues (2004). A digital ion trap mass spectrometer coupled with atmospheric pressure ion sources. Journal of Mass Spectrometry.](https://doi.org/10.1002/jms.637)\n16. [Quadrupole Ion Traps and Trap Arrays: Geometry, Material, Scale, Performance (European Journal of Mass Spectrometry, 2007)](https://sage.cnpereading.com/doi/10.1255/ejms.832)\n17. [Alexander Makarov (2000). Electrostatic Axially Harmonic Orbital Trapping: A High-Performance Technique of Mass Analysis. Analytical Chemistry.](https://doi.org/10.1021/ac991131p)\n18. [Alexander Makarov and colleagues (2006). Performance Evaluation of a Hybrid Linear Ion Trap/Orbitrap Mass Spectrometer. Analytical Chemistry.](https://doi.org/10.1021/ac0518811)\n19. [Systematic Comparison of a Two-dimensional Ion Trap and a Three-dimensional Ion Trap Mass Spectrometer in Proteomics](https://pmc.ncbi.nlm.nih.gov/articles/PMC1487187/)\n20. [Rapid assay development for low input targeted proteomics using a versatile linear ion trap (Nature Communications, 2025)](https://www.nature.com/articles/s41467-025-58757-8)\n21. [Hybrid Quadrupole Mass Filter – Radial Ejection Linear Ion Trap and Intelligent Data Acquisition Enable Highly Multiplex Targeted Proteomics (Thermo Stellar)](https://pmc.ncbi.nlm.nih.gov/articles/PMC11956834/)\n22. [Dalton T. Snyder and colleagues (2015). Miniature and Fieldable Mass Spectrometers: Recent Advances. Analytical Chemistry.](https://doi.org/10.1021/acs.analchem.5b03070)\n23. [Multiplexing Quadrupole and Ion Trap Operation Modes on a 'Brick' Miniature Mass Spectrometer (Molecules, 2023)](https://www.mdpi.com/1420-3049/28/22/7640)\n24. [Ion traps in modern mass spectrometry (Mass Spectrometry Reviews)](https://analyticalsciencejournals.onlinelibrary.wiley.com/doi/10.1002/mas.21549)\n\n---\n*Topic: Encyclopedia › Physical world and mathematics › Chemistry › Chemical principles and methods › Analytical chemistry › Mass spectrometry methods*\n\n*Initially written Sep 29, 2026 · Reviewed: Sep 30, 2026 · Edited: Sep 30, 2026 · Last review: Sep 30, 2026*\n\n*Copyright 2026 EdgeChat AI, a subsidiary of Biostate AI.*\n\nLicense: Edgepedia Community License 1.0, https://www.edgepedia.org/edgepedia/license\n",
 "same_as": [],
 "url": "https://www.edgepedia.org/ion-trap-mass-spectrometry",
 "markdown_url": "https://www.edgepedia.org/ion-trap-mass-spectrometry.md",
 "license": {
  "name": "Edgepedia Community License 1.0",
  "url": "https://www.edgepedia.org/edgepedia/license",
  "summary": "Free with credit, commercial use included. AI training is open to everyone. For other uses, organizations over USD 100M in revenue or 100M monthly users license separately.",
  "spdx": "LicenseRef-Edgepedia-Community-1.0"
 },
 "credit": "\"Ion trap mass spectrometry\", Edgepedia (EdgeChat), https://www.edgepedia.org/ion-trap-mass-spectrometry. Edgepedia Community License 1.0.",
 "credit_md": "\"[Ion trap mass spectrometry](https://www.edgepedia.org/ion-trap-mass-spectrometry)\", Edgepedia (EdgeChat), [https://www.edgepedia.org/ion-trap-mass-spectrometry](https://www.edgepedia.org/ion-trap-mass-spectrometry). [Edgepedia Community License 1.0](https://www.edgepedia.org/edgepedia/license).",
 "credit_html": "\"<a href=\"https://www.edgepedia.org/ion-trap-mass-spectrometry\">Ion trap mass spectrometry</a>\", Edgepedia (EdgeChat), <a href=\"https://www.edgepedia.org/ion-trap-mass-spectrometry\">https://www.edgepedia.org/ion-trap-mass-spectrometry</a>. <a href=\"https://www.edgepedia.org/edgepedia/license\">Edgepedia Community License 1.0</a>.",
 "speakable": "Ion trap mass spectrometry is a mass spectrometry technique that stores ions in a radiofrequency quadrupole field, performing tandem MS in time up to MS10."
}