{
 "id": "epazh2047m",
 "slug": "nano-liquid-chromatography",
 "title": "Nano liquid chromatography",
 "updated": "2026-10-15",
 "topic_path": [
  {
   "id": "physical",
   "label": "Physical world and mathematics",
   "api_url": "https://www.edgepedia.org/api/v1/topics/physical"
  },
  {
   "id": "physical.chemistry",
   "label": "Chemistry",
   "api_url": "https://www.edgepedia.org/api/v1/topics/physical.chemistry"
  },
  {
   "id": "physical.chemistry.methods",
   "label": "Chemical principles and methods",
   "api_url": "https://www.edgepedia.org/api/v1/topics/physical.chemistry.methods"
  },
  {
   "id": "physical.chemistry.methods.analytical-chemistry",
   "label": "Analytical chemistry",
   "api_url": "https://www.edgepedia.org/api/v1/topics/physical.chemistry.methods.analytical-chemistry"
  },
  {
   "id": "physical.chemistry.methods.chromatography",
   "label": "Chromatography",
   "api_url": "https://www.edgepedia.org/api/v1/topics/physical.chemistry.methods.chromatography"
  },
  {
   "id": "physical.chemistry.methods.chromatography-modes",
   "label": "Chromatography modes and practice",
   "api_url": "https://www.edgepedia.org/api/v1/topics/physical.chemistry.methods.chromatography-modes"
  }
 ],
 "geo": [
  {
   "id": "geo.nongeo.t1946.physical.chemistry.methods.chromatography",
   "label": "Non-geographic · 1946 to 2000: Chromatography",
   "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t1946.physical.chemistry.methods.chromatography",
   "path": [
    {
     "id": "geo.nongeo",
     "label": "Non-geographic",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo"
    },
    {
     "id": "geo.nongeo.t1946",
     "label": "Non-geographic · 1946 to 2000",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t1946"
    },
    {
     "id": "geo.nongeo.t1946.physical",
     "label": "Physical world and mathematics",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t1946.physical"
    },
    {
     "id": "geo.nongeo.t1946.physical.chemistry",
     "label": "Chemistry",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t1946.physical.chemistry"
    },
    {
     "id": "geo.nongeo.t1946.physical.chemistry.methods",
     "label": "Chemical principles and methods",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t1946.physical.chemistry.methods"
    },
    {
     "id": "geo.nongeo.t1946.physical.chemistry.methods.analytical-chemistry",
     "label": "Analytical chemistry",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t1946.physical.chemistry.methods.analytical-chemistry"
    },
    {
     "id": "geo.nongeo.t1946.physical.chemistry.methods.chromatography",
     "label": "Chromatography",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t1946.physical.chemistry.methods.chromatography"
    }
   ]
  }
 ],
 "excerpt": "Nano liquid chromatography is a miniaturized form of high-performance liquid chromatography that separates tiny samples on 10–150 μm capillary columns at nanoliter-per-minute flow rates, used mainly for bottom-up proteomics.",
 "snippet": "Nano liquid chromatography is a miniaturized form of high-performance liquid chromatography that separates tiny samples on 10–150 μm capillary columns at nanoliter-per-minute flow rates, used mainly for bottom-up proteomics.",
 "node": "physical.chemistry.methods.chromatography-modes",
 "markdown": "# Nano liquid chromatography\n\nNano liquid chromatography (nano LC) is a miniaturized form of high-performance liquid chromatography that separates tiny samples on capillary columns of roughly 10–150 μm internal diameter at mobile-phase flow rates in the nanoliter-per-minute range.<sup>[1](http://www.chromedia.org/chromedia?waxtrapp=pojxhEsHqnOxmOlIEcCzBqGpGJC)</sup> The commonly accepted standard column is 75 μm internal diameter running near 250 nL/min.<sup>[1](http://www.chromedia.org/chromedia?waxtrapp=pojxhEsHqnOxmOlIEcCzBqGpGJC)</sup> By convention, capillary LC uses 100–500 μm columns at 1–10 μL/min, micro LC runs above 10 μL/min, and conventional 4.6 mm analytical columns run at about 1000–1200 μL/min.<sup>[2](https://www.sciencedirect.com/science/article/abs/pii/S0165993619301207)</sup><sup> • </sup><sup>[3](https://lcms.cz/labrulez-bucket-strapi-h3hsga3/WP_70817_LC_Miniaturization_WP_70817_EN_a880da432b/WP-70817-LC-Miniaturization-WP70817-EN.pdf)</sup> The payoff is sensitivity: for the same injected amount, signal on concentration-sensitive detectors rises steeply as the column narrows, which is why sample-limited digests and extracts are run at nanoflow.\n\n| Property | Typical value |\n|---|---|\n| Column internal diameter | 10–150 μm; standard 75 μm<sup>[1](http://www.chromedia.org/chromedia?waxtrapp=pojxhEsHqnOxmOlIEcCzBqGpGJC)</sup> |\n| Flow rate | 10–1000 nL/min; ~250 nL/min typical<sup>[1](http://www.chromedia.org/chromedia?waxtrapp=pojxhEsHqnOxmOlIEcCzBqGpGJC)</sup><sup> • </sup><sup>[2](https://www.sciencedirect.com/science/article/abs/pii/S0165993619301207)</sup> |\n| Theoretical sensitivity gain vs 4.6 mm column | ~3800 to 4000× for equal load<sup>[1](http://www.chromedia.org/chromedia?waxtrapp=pojxhEsHqnOxmOlIEcCzBqGpGJC)</sup><sup> • </sup><sup>[4](https://assets.thermofisher.com/TFS-Assets/CMD/brochures/eb-65351-nano-lc-proteomics-eb65251-en.pdf)</sup> |\n| Practical sensitivity gain vs analytical flow | About two orders of magnitude<sup>[4](https://assets.thermofisher.com/TFS-Assets/CMD/brochures/eb-65351-nano-lc-proteomics-eb65251-en.pdf)</sup> |\n| Detection limits | Below 75 zmol for proteins; amol-range peptide quantification<sup>[5](https://pubs.acs.org/doi/abs/10.1021/ac030096q)</sup><sup> • </sup><sup>[6](https://sciex.com/content/dam/SCIEX/pdf/tech-notes/all/peptide_quantification_Low_Flow_sensitivity.pdf)</sup> |\n| Peak capacity | 300–500 on state-of-the-art 50 cm columns; up to ~\\( 10^{3} \\) on long high-efficiency capillaries<sup>[7](https://www.chromatographyonline.com/view/nano-lc-principles-evolution-and-state-art-technique)</sup><sup> • </sup><sup>[5](https://pubs.acs.org/doi/abs/10.1021/ac030096q)</sup> |\n| Dominant application | Bottom-up proteomics coupled to nanoESI-MS/MS<sup>[4](https://assets.thermofisher.com/TFS-Assets/CMD/brochures/eb-65351-nano-lc-proteomics-eb65251-en.pdf)</sup> |\n\n## How it works\n\nUV absorbance and electrospray ionization mass spectrometry (ESI-MS) are concentration-sensitive detectors: their signal is proportional to the concentration of analyte in the peak eluting from the column, not to the mass flow.<sup>[3](https://lcms.cz/labrulez-bucket-strapi-h3hsga3/WP_70817_LC_Miniaturization_WP_70817_EN_a880da432b/WP-70817-LC-Miniaturization-WP70817-EN.pdf)</sup> For a fixed injected amount, peak concentration at the column outlet is inversely proportional to the square of the column diameter, so the theoretical gain from shrinking a 4.6 mm column to 75 μm follows the downscale factor \\( f = d_{\\mathrm{standard}}^{2} / d_{\\mathrm{nano}}^{2} \\), calculated as almost 3800.<sup>[1](http://www.chromedia.org/chromedia?waxtrapp=pojxhEsHqnOxmOlIEcCzBqGpGJC)</sup> Experimentally, nanoLC/nanoESI-MS sensitivity increased linearly with decreasing flow rate, approximately inversely proportional to the square of the capillary inner diameter, across 20–400 nL/min.<sup>[5](https://pubs.acs.org/doi/abs/10.1021/ac030096q)</sup> Electrospray itself improves at low flow: the benefits of true nano-ESI emerge below about 50 nL/min with spray tips of a few micrometers outer diameter, producing smaller droplets and more efficient ionization.<sup>[8](https://www.frontiersin.org/journals/molecular-biosciences/articles/10.3389/fmolb.2022.857505/full)</sup> In practice, the theoretical downscale gain of ~3800–4000× shrinks to about two orders of magnitude, because dispersion, loading limits, and ionization losses intervene.<sup>[4](https://assets.thermofisher.com/TFS-Assets/CMD/brochures/eb-65351-nano-lc-proteomics-eb65251-en.pdf)</sup> Peak capacities run 300–500 on current 50 cm columns and approach \\( 10^{3} \\) on 87 cm capillaries packed with 3 μm C18 at 18,000 psi.<sup>[7](https://www.chromatographyonline.com/view/nano-lc-principles-evolution-and-state-art-technique)</sup><sup> • </sup><sup>[5](https://pubs.acs.org/doi/abs/10.1021/ac030096q)</sup>\n\nMiniaturization also imposes constraints. As column dimensions shrink, peak volume decreases steeply, so every flow-through space (connection capillaries, detector cell) must be miniaturized or extra-column band broadening destroys the separation.<sup>[9](https://www.sciencedirect.com/science/article/abs/pii/S002196731501078X)</sup> Pressure drop across packed beds rises as particle diameter falls,<sup>[9](https://www.sciencedirect.com/science/article/abs/pii/S002196731501078X)</sup> and dedicated capillary-column fabrication is required for proper nanoflow operation.<sup>[10](https://pubs.rsc.org/en/content/articlelanding/2020/ay/d0ay01194k)</sup>\n\n## How it is done\n\nEarly instruments delivered nanoliter flows with flow splitters from pumps running at analytical rates; split-free direct-flow systems were developed in 2003 and commercialized in 2005, and modern instruments such as the UltiMate 3000 RSLCnano deliver 20 nL/min to 50 μL/min at UHPLC pressures with 20 μm internal-diameter connection tubing.<sup>[7](https://www.chromatographyonline.com/view/nano-lc-principles-evolution-and-state-art-technique)</sup><sup> • </sup><sup>[3](https://lcms.cz/labrulez-bucket-strapi-h3hsga3/WP_70817_LC_Miniaturization_WP_70817_EN_a880da432b/WP-70817-LC-Miniaturization-WP70817-EN.pdf)</sup>\n\n**A typical proteomics run** loads the digest onto a trap column at high flow, washes salts, then back-flushes the trap onto the analytical column for gradient elution. In one low-nanoflow configuration, fast sample loading at 1500 bar (about 1 μL/min at 50 °C) with washing and equilibration in 2 min maintains a stable 100 nL/min separation on a 50 μm × 15 cm column feeding a 10 μm internal-diameter glass emitter through a FAIMS interface.<sup>[11](https://pmc.ncbi.nlm.nih.gov/articles/PMC10753523/)</sup> Columns are predominantly packed in fused-silica capillaries with in-capillary frits; EASY-Spray-style products fuse the column to the emitter to minimize post-column dispersion, and 1200 bar pumps permit 75 cm columns.<sup>[4](https://assets.thermofisher.com/TFS-Assets/CMD/brochures/eb-65351-nano-lc-proteomics-eb65251-en.pdf)</sup><sup> • </sup><sup>[7](https://www.chromatographyonline.com/view/nano-lc-principles-evolution-and-state-art-technique)</sup> Load capacity is limited: a well-packed 75 μm × 15 cm C18 column tolerates roughly 10 ng of a 1000 Da peptide before mass-overloading broadens peaks.<sup>[1](http://www.chromedia.org/chromedia?waxtrapp=pojxhEsHqnOxmOlIEcCzBqGpGJC)</sup> Most scientists operate at 200–400 nL/min as a trade-off between sensitivity, repeatability, and robustness, with modern instruments holding retention-time RSD below 0.1%.<sup>[4](https://assets.thermofisher.com/TFS-Assets/CMD/brochures/eb-65351-nano-lc-proteomics-eb65251-en.pdf)</sup>\n\n## Origin\n\nNano LC grew out of a long miniaturization lineage in column liquid chromatography, and the term itself was coined in the late 1990s.<sup>[9](https://www.sciencedirect.com/science/article/abs/pii/S002196731501078X)</sup> A micro-HPLC system for packed and open tubular capillary columns was reported by D. Ishii and colleagues in 1977 in the Journal of Chromatography A.<sup>[12](https://doi.org/10.1016/s0021-9673%2800%2999351-8)</sup> In 1988, Karl Erik Karlsson and [Milos Novotny](https://www.edgepedia.org/milos-v-novotny) showed in Analytical Chemistry that slurry-packed microcolumns of very small inner diameter could reach extreme efficiency, preparing a 1.95 m column of 44 μm internal diameter with 5 μm particles that delivered 226,000 theoretical plates in 33 min.<sup>[13](https://doi.org/10.1021/ac00168a006)</sup> On the detection side, Mark R. Emmett and Richard M. Caprioli reported micro-electrospray MS for ultra-high-sensitivity peptide and protein analysis in 1994,<sup>[14](https://doi.org/10.1016/1044-0305%2894%2985001-1)</sup> and in 1996 Matthias Wilm and colleagues demonstrated femtomole protein sequencing by nano-electrospray MS,<sup>[15](https://doi.org/10.1038/379466a0)</sup> the interface that nano LC needed. The same year, Gary A. Valaskovic, Neil L. Kelleher, and [Fred W. McLafferty](https://www.edgepedia.org/fred-w-mclafferty) reached attomole protein characterization by capillary electrophoresis-MS in Science.<sup>[16](https://doi.org/10.1126/science.273.5279.1199)</sup> In 1999, Reinhard Juraschek, Thomas Dülcks, and [Michael Karas](https://www.edgepedia.org/michael-karas) showed nanoelectrospray is more than a minimized-flow ESI source.<sup>[17](https://doi.org/10.1016/s1044-0305%2898%2900157-3)</sup> Commercial nano LC instruments feature an accurate flow splitter.<sup>[9](https://www.sciencedirect.com/science/article/abs/pii/S002196731501078X)</sup> In 2007, J. Srbek and colleagues reported practical protein identification on the first commercially available microfluidic nano-ESI device coupled with nano LC, the HPLC-chip.<sup>[18](https://doi.org/10.1002/jssc.200700053)</sup>\n\n## Variants\n\n**Chip-based nano LC** integrates the sample loop, enrichment column, separation column, and nanospray emitter into a single microfluidic platform without fittings or unions; the first LC microchips appeared in the early 1990s.<sup>[9](https://www.sciencedirect.com/science/article/abs/pii/S002196731501078X)</sup> **Trap-and-elute** configurations use a short trap column for fast loading and cleanup before back-flushing onto the analytical column; in a low-nanoflow DIA workflow this cut the method cycle from 20 to 14.4 min at a cost of roughly 14–17% fewer protein identifications.<sup>[11](https://pmc.ncbi.nlm.nih.gov/articles/PMC10753523/)</sup> **Monolithic capillary columns**, introduced in the early 1990s, offer in-situ preparation, high permeability, high efficiency, and no retaining frit, in 20–500 μm capillaries.<sup>[2](https://www.sciencedirect.com/science/article/abs/pii/S0165993619301207)</sup><sup> • </sup><sup>[1](http://www.chromedia.org/chromedia?waxtrapp=pojxhEsHqnOxmOlIEcCzBqGpGJC)</sup>\n\n## Applications\n\n[Bottom-up proteomics](https://www.edgepedia.org/bottom-up-proteomics) is the dominant use: nano LC-MS/MS identifies thousands of proteins from tryptic digests, and its sensitivity permits analysis of sample-limited peptide mixtures such as proteins isolated from 2D gel spots.<sup>[4](https://assets.thermofisher.com/TFS-Assets/CMD/brochures/eb-65351-nano-lc-proteomics-eb65251-en.pdf)</sup><sup> • </sup><sup>[19](https://experiments.springernature.com/articles/10.1007/978-1-61779-319-6_9)</sup> Measured detection limits reach below 75 zmol for individual proteins and protein identification from 0.5 pg of whole proteome extract on a 15 μm internal-diameter column at ~20 nL/min.<sup>[5](https://pubs.acs.org/doi/abs/10.1021/ac030096q)</sup> [Single-cell proteomics](https://www.edgepedia.org/single-cell-proteomics) depends on it: the nanodroplet processing platform ([nanoPOTS](https://www.edgepedia.org/nanopots)) reported by Y. Zhu and colleagues in 2018 profiled proteomes of 10–100 mammalian cells,<sup>[20](https://doi.org/10.1038/s41467-018-03367-w)</sup> and library-free DIA on a 50 μm column yielded more than 1,700 protein groups in individual HeLa cells at 100 cells/day.<sup>[11](https://pmc.ncbi.nlm.nih.gov/articles/PMC10753523/)</sup> In small-molecule trace bioanalysis, a trap-and-elute nanoflow setup (0.3 μL/min, 75 μm × 150 mm column) multiplied signal intensity and sensitivity for many compounds, but benefits were limited for metabolites below 200 Da or logP below −0.5, and some polar compounds including most amino acids were completely lost.<sup>[8](https://www.frontiersin.org/journals/molecular-biosciences/articles/10.3389/fmolb.2022.857505/full)</sup>\n\n## Limitations and alternatives\n\nNano-flow LC has been the mainstay of proteome research for over 20 years, but it suffers from difficulty manufacturing reproducible, long-lasting columns, unstable ESI over long periods, rapid chromatographic overloading, MS saturation, and long sample-transfer overhead times.<sup>[21](https://www.nature.com/articles/s41467-019-13973-x)</sup> At nanoflow rates, dead volume is unforgiving: 0.5 μL, negligible at 1 mL/min, ruins performance at 0.3 μL/min, and leaks are hard to see visually (clogs raise pressure in splitless systems but reduce flow in splitter systems).<sup>[4](https://assets.thermofisher.com/TFS-Assets/CMD/brochures/eb-65351-nano-lc-proteomics-eb65251-en.pdf)</sup>\n\n**Compared with micro-flow LC**, a 1 mm column has 178× the cross-sectional area of a 75 μm nanoflow column, and with narrow peaks and 3% DMSO only about 5× more sample was needed for similar identifications at 28 Hz acquisition; micro-flow also tolerated a 1550-injection, ~40-day test with extremely low carryover and one column serving more than 7500 samples.<sup>[21](https://www.nature.com/articles/s41467-019-13973-x)</sup> **Compared with capillary electrochromatography (CEC)**, nano-LC with C18 detected 20 peptides with 88% sequence coverage of cytochrome c digest versus 59–76% for CEC phases, while CEC offered higher separation efficiency and 15–50% shorter analysis times but fewer separated peptides and longer equilibration; sheath-liquid CEC-MS interfaces can lose sensitivity through dilution and current instability.<sup>[22](https://analyticalsciencejournals.onlinelibrary.wiley.com/doi/10.1002/elps.201200157)</sup>\n\n## References\n\n1. [Nano LC - Chromedia](http://www.chromedia.org/chromedia?waxtrapp=pojxhEsHqnOxmOlIEcCzBqGpGJC)\n2. [Miniaturization of liquid chromatography coupled to mass spectrometry: 1. Current trends on miniaturized LC columns](https://www.sciencedirect.com/science/article/abs/pii/S0165993619301207)\n3. [Miniaturization of Liquid Chromatography: Why Do We Do It? (Thermo Scientific WP-70817)](https://lcms.cz/labrulez-bucket-strapi-h3hsga3/WP_70817_LC_Miniaturization_WP_70817_EN_a880da432b/WP-70817-LC-Miniaturization-WP70817-EN.pdf)\n4. [Nano-LC: Big Data From Tiny Volumes (Thermo Fisher technical e-book)](https://assets.thermofisher.com/TFS-Assets/CMD/brochures/eb-65351-nano-lc-proteomics-eb65251-en.pdf)\n5. [Ultrasensitive Proteomics Using High-Efficiency On-Line Micro-SPE-NanoLC-NanoESI MS and MS/MS (Shen et al., Anal. Chem.)](https://pubs.acs.org/doi/abs/10.1021/ac030096q)\n6. [Exploring the Sensitivity Differences for Peptide Quantification in the Low Flow Rate Regime (NanoLC 400 System)](https://sciex.com/content/dam/SCIEX/pdf/tech-notes/all/peptide_quantification_Low_Flow_sensitivity.pdf)\n7. [Nano LC: Principles, Evolution, and State-of-the-Art of the Technique](https://www.chromatographyonline.com/view/nano-lc-principles-evolution-and-state-art-technique)\n8. [Systematic Investigation of LC Miniaturization to Increase Sensitivity in Wide-Target LC-MS-Based Trace Bioanalysis of Small Molecules](https://www.frontiersin.org/journals/molecular-biosciences/articles/10.3389/fmolb.2022.857505/full)\n9. [Review: Instrument platforms for nano liquid chromatography](https://www.sciencedirect.com/science/article/abs/pii/S002196731501078X)\n10. [Nano-liquid chromatography-mass spectrometry and recent applications in omics investigations](https://pubs.rsc.org/en/content/articlelanding/2020/ay/d0ay01194k)\n11. [A High-Sensitivity Low-Nanoflow LC-MS Configuration for High-Throughput Sample-Limited Proteomics](https://pmc.ncbi.nlm.nih.gov/articles/PMC10753523/)\n12. [A study of micro-high-performance liquid chromatography (Journal of Chromatography A, 1977)](https://doi.org/10.1016/s0021-9673%2800%2999351-8)\n13. [Karl Erik. Karlsson, Milos. Novotny (1988). Separation efficiency of slurry-packed liquid chromatography microcolumns with very small inner diameters. Analytical Chemistry.](https://doi.org/10.1021/ac00168a006)\n14. [Micro-electrospray mass spectrometry: Ultra-high-sensitivity analysis of peptides and proteins (Journal of the American Society for Mass Spectrometry, 1994)](https://doi.org/10.1016/1044-0305%2894%2985001-1)\n15. [Matthias Wilm and colleagues (1996). Femtomole sequencing of proteins from polyacrylamide gels by nano-electrospray mass spectrometry. Nature.](https://doi.org/10.1038/379466a0)\n16. [Gary A. Valaskovic, Neil L. Kelleher, Fred W. McLafferty (1996). Attomole Protein Characterization by Capillary Electrophoresis-Mass Spectrometry. Science.](https://doi.org/10.1126/science.273.5279.1199)\n17. [Nanoelectrospray—More than just a minimized-flow electrospray ionization source (Journal of the American Society for Mass Spectrometry, 1999)](https://doi.org/10.1016/s1044-0305%2898%2900157-3)\n18. [Jan Srbek and colleagues (2007). Chip‐based nano‐LC‐MS/MS identification of proteins in complex biological samples using a novel polymer microfluidic device. Journal of Separation Science.](https://doi.org/10.1002/jssc.200700053)\n19. [Nano LC–MS/MS: A Robust Setup for Proteomic Analysis (Springer Protocols chapter)](https://experiments.springernature.com/articles/10.1007/978-1-61779-319-6_9)\n20. [Ying Zhu and colleagues (2018). Nanodroplet processing platform for deep and quantitative proteome profiling of 10–100 mammalian cells. Nature Communications.](https://doi.org/10.1038/s41467-018-03367-w)\n21. [Robust, reproducible and quantitative analysis of thousands of proteomes by micro-flow LC–MS/MS](https://www.nature.com/articles/s41467-019-13973-x)\n22. [Nano-liquid chromatography and capillary electrochromatography hyphenated with mass spectrometry for tryptic digest protein analysis: A comparison](https://analyticalsciencejournals.onlinelibrary.wiley.com/doi/10.1002/elps.201200157)\n\n---\n*Topic: Encyclopedia › Physical world and mathematics › Chemistry › Chemical principles and methods › Analytical chemistry › Chromatography › Chromatography modes and practice*\n\n*Initially written Sep 29, 2026 · Edited: Oct 15, 2026*\n\n*Copyright 2026 EdgeChat AI, a subsidiary of Biostate AI.*\n\nLicense: Edgepedia Community License 1.0, https://www.edgepedia.org/edgepedia/license\n",
 "same_as": [],
 "url": "https://www.edgepedia.org/nano-liquid-chromatography",
 "markdown_url": "https://www.edgepedia.org/nano-liquid-chromatography.md",
 "license": {
  "name": "Edgepedia Community License 1.0",
  "url": "https://www.edgepedia.org/edgepedia/license",
  "summary": "Free with credit, commercial use included. AI training is open to everyone. For other uses, organizations over USD 100M in revenue or 100M monthly users license separately.",
  "spdx": "LicenseRef-Edgepedia-Community-1.0"
 },
 "credit": "\"Nano liquid chromatography\", Edgepedia (EdgeChat), https://www.edgepedia.org/nano-liquid-chromatography. Edgepedia Community License 1.0.",
 "credit_md": "\"[Nano liquid chromatography](https://www.edgepedia.org/nano-liquid-chromatography)\", Edgepedia (EdgeChat), [https://www.edgepedia.org/nano-liquid-chromatography](https://www.edgepedia.org/nano-liquid-chromatography). [Edgepedia Community License 1.0](https://www.edgepedia.org/edgepedia/license).",
 "credit_html": "\"<a href=\"https://www.edgepedia.org/nano-liquid-chromatography\">Nano liquid chromatography</a>\", Edgepedia (EdgeChat), <a href=\"https://www.edgepedia.org/nano-liquid-chromatography\">https://www.edgepedia.org/nano-liquid-chromatography</a>. <a href=\"https://www.edgepedia.org/edgepedia/license\">Edgepedia Community License 1.0</a>.",
 "speakable": "Nano liquid chromatography is a miniaturized form of high-performance liquid chromatography that separates tiny samples on 10–150 μm capillary columns at nanoliter-per-minute flow rates, used mainly for bottom-up proteomics."
}
