 "id": "epxd1cf64n",
 "slug": "progressive-collapse-analysis",
 "title": "Progressive collapse analysis",
 "updated": "2026-10-15",
 "topic_path": [
  {
   "id": "technology",
   "label": "Technology and the built world",
   "api_url": "https://www.edgepedia.org/api/v1/topics/technology"
  },
  {
   "id": "technology.built",
   "label": "Architecture, buildings, and civil works",
   "api_url": "https://www.edgepedia.org/api/v1/topics/technology.built"
  }
 ],
 "geo": [
  {
   "id": "geo.nongeo.t1946.technology.built",
   "label": "Non-geographic · 1946 to 2000: Architecture, buildings, and civil works",
   "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t1946.technology.built",
   "path": [
    {
     "id": "geo.nongeo",
     "label": "Non-geographic",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo"
    },
    {
     "id": "geo.nongeo.t1946",
     "label": "Non-geographic · 1946 to 2000",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t1946"
    },
    {
     "id": "geo.nongeo.t1946.technology",
     "label": "Technology and the built world",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t1946.technology"
    },
    {
     "id": "geo.nongeo.t1946.technology.built",
     "label": "Architecture, buildings, and civil works",
     "api_url": "https://www.edgepedia.org/api/v1/geo/geo.nongeo.t1946.technology.built"
    }
   ]
  }
 ],
 "excerpt": "Progressive collapse analysis is a structural engineering method that checks whether a building can absorb local damage, such as losing a column, without disproportionate collapse.",
 "snippet": "Progressive collapse analysis is a structural engineering method that checks whether a building can absorb local damage, such as losing a column, without disproportionate collapse.",
 "node": "technology.built",
 "markdown": "# Progressive collapse analysis\n\nProgressive collapse analysis is a structural engineering method that simulates how initial local damage, such as the loss of a column, propagates through a building and whether the remaining structure can absorb it. [Progressive collapse](https://www.edgepedia.org/progressive-collapse) is defined as an extent of damage or collapse that is disproportionate to the magnitude of the initiating event.<sup>[1](https://www.gsa.gov/system/files/Progressive_Collapse_2016.pdf)</sup> The method redistributes the loads that a damaged member carried onto the surviving structure and checks whether that redistribution succeeds or triggers a chain reaction of failures.<sup>[2](https://nvlpubs.nist.gov/nistpubs/Legacy/BSS/nbsbuildingscience98.pdf)</sup> Its modern form was driven by three events: the [Ronan Point](https://www.edgepedia.org/ronan-point) collapse of 1968, the bombing of the Murrah Federal Building in 1995, and the World Trade Center collapse in 2001.<sup>[3](https://link.springer.com/article/10.1007/s13369-024-08847-4)</sup>\n\n| Key fact | Value |\n|---|---|\n| Gravity load combination (GSA alternate path) | \\( G = 1.2 D + (0.5 L \\text{ or } 0.2 S) \\)<sup>[1](https://www.gsa.gov/system/files/Progressive_Collapse_2016.pdf)</sup> |\n| Load increase factor, linear static, steel frames | 0.9 \\( m_{\\mathrm{LIF}} \\) + 1.1 (deformation-controlled); 2.0 (force-controlled)<sup>[1](https://www.gsa.gov/system/files/Progressive_Collapse_2016.pdf)</sup> |\n| Dynamic increase factor, nonlinear static, steel frames | \\( \\Omega_{N} = 1.08 + 0.76/(\\theta_{pra}/\\theta_{y} + 0.83) \\)<sup>[1](https://www.gsa.gov/system/files/Progressive_Collapse_2016.pdf)</sup> |\n| Column removal time limit (nonlinear dynamic) | Less than one tenth of the period of the vertical response mode of the bays above the removed column<sup>[1](https://www.gsa.gov/system/files/Progressive_Collapse_2016.pdf)</sup> |\n| Measured dynamic load factors, RC frames | About 1.1 to 1.15 in explosive column-removal tests; 1.5 recommended as realistic<sup>[4](https://www.mmiengineering.com/wp-content/uploads/2014/08/ICE-Paper.pdf)</sup> |\n| Tie rotation capacity required for members acting as ties | 0.20 rad (11 degrees)<sup>[5](https://wrap.warwick.ac.uk/id/eprint/117589/1/WRAP-historical-review-prescriptive-design-rules-robustness-collapse-Ronan-Point-Russell-2019.pdf)</sup> |\n| Example robustness index, 10-story RC frame | \\( R = 1.54 \\), indicating no collapse under the three column removal cases considered<sup>[6](https://tsapps.nist.gov/publication/get_pdf.cfm?pub_id=922173)</sup> |\n\n## How it works\n\nThe method rests on the alternate load path concept: a primary load-bearing member is notionally removed, and the analysis determines whether loads can bridge over the gap, limiting damage to a localized area.<sup>[1](https://www.gsa.gov/system/files/Progressive_Collapse_2016.pdf)</sup> The intent is to allow the initial failure but prevent further collapse.<sup>[2](https://nvlpubs.nist.gov/nistpubs/Legacy/BSS/nbsbuildingscience98.pdf)</sup>\n\nSeveral mechanisms supply the bridging capacity. After a column is lost, the spans above re-equilibrate to larger spans through a change from flexural response to membrane action, or a combination of both; in bridges this re-equilibration follows sudden column loss directly.<sup>[7](https://www.sciencedirect.com/science/article/pii/S2590123023002177)</sup> In frames, compressive arching, catenary action (beams/slabs hanging like chains, carrying load in tension) in beams and floor slabs, and slab membrane action contribute, with reduced-order finite element models capturing these geometrically nonlinear mechanisms explicitly.<sup>[6](https://tsapps.nist.gov/publication/get_pdf.cfm?pub_id=922173)</sup>\n\n## How it is done\n\nGuidelines approve four analytical approaches: linear static, nonlinear static, linear dynamic, and nonlinear dynamic analysis.<sup>[4](https://www.mmiengineering.com/wp-content/uploads/2014/08/ICE-Paper.pdf)</sup> The 2016 GSA guidelines employ three of them, Linear Static (LSP), Nonlinear Static (NSP), and Nonlinear Dynamic (NDP), following [ASCE 41](https://www.edgepedia.org/asce-41) with modifications for progressive collapse.<sup>[1](https://www.gsa.gov/system/files/Progressive_Collapse_2016.pdf)</sup>\n\nThe workflow is:\n\n1. Select removal scenarios. GSA specifies removal at the middle of the long side, the middle of the short side, and the corner, only at ground level, one column at a time; DoD considers columns at each floor level.<sup>[4](https://www.mmiengineering.com/wp-content/uploads/2014/08/ICE-Paper.pdf)</sup>\n2. Apply the gravity load combination \\( G = 1.2 D + (0.5 L \\text{ or } 0.2 S) \\).<sup>[1](https://www.gsa.gov/system/files/Progressive_Collapse_2016.pdf)</sup>\n3. For static procedures, amplify loads. Linear static uses load increase factors of 0.9 \\( m_{\\mathrm{LIF}} \\) + 1.1 for deformation-controlled and 2.0 for force-controlled actions in steel frames, and 1.2 \\( m_{\\mathrm{LIF}} \\) + 0.80 for reinforced concrete frames.<sup>[1](https://www.gsa.gov/system/files/Progressive_Collapse_2016.pdf)</sup> Nonlinear static uses dynamic increase factors \\( \\Omega_{N} = 1.08 + 0.76/(\\theta_{pra}/\\theta_{y} + 0.83) \\) for steel and \\( \\Omega_{N} = 1.04 + 0.45/(\\theta_{pra}/\\theta_{y} + 0.48) \\) for reinforced concrete, with a constant \\( \\Omega_{N} = 2 \\) for load-bearing wall construction.<sup>[1](https://www.gsa.gov/system/files/Progressive_Collapse_2016.pdf)</sup> Nonlinear procedures must apply loads in at least 10 load steps with iterative convergence before each increment.<sup>[1](https://www.gsa.gov/system/files/Progressive_Collapse_2016.pdf)</sup>\n4. For dynamic procedures, remove the column suddenly. Removal duration must be less than one tenth of the period of the vertical response mode of the bays above the removed column.<sup>[1](https://www.gsa.gov/system/files/Progressive_Collapse_2016.pdf)</sup> In LS-DYNA this is done by deleting the beam elements representing the column in a restart analysis of the gravity-loaded model.<sup>[6](https://tsapps.nist.gov/publication/get_pdf.cfm?pub_id=922173)</sup> A force-based alternative first runs a static pushdown of the undamaged structure to record the column reaction \\( R_{c} \\), then applies a counterforce of magnitude \\( R_{c} \\) over a removal time \\( T_{\\mathrm{Rem}} \\) taken as \\( (1/11)T_{v} \\), consistent with the GSA limit, where \\( T_{v} \\) is the first vertical vibration mode period.<sup>[8](https://iris.unitn.it/retrieve/fccde151-2acc-4ef2-99c2-2f9f646ac871/EFA_Progressive_Collapse_2024_PUBLISHED-compressed.pdf)</sup>\n5. Judge the result against acceptance criteria. Plastic rotation angles \\( \\theta_{pra} \\) come from ASCE 41 tables for the Collapse Prevention or Life Safety response levels.<sup>[1](https://www.gsa.gov/system/files/Progressive_Collapse_2016.pdf)</sup> These criteria were based primarily on the seismic acceptance criteria of ASCE/SEI 41-13, Seismic Evaluation and Retrofit, and are material-specific, drawn from separate ASCE 41 chapters for steel, reinforced concrete, masonry, and timber and cold-formed steel.<sup>[9](https://tsapps.nist.gov/publication/get_pdf.cfm?pub_id=922168)</sup> DoD procedures use demand capacity ratios to assess element capability, following the FEMA 273 approach.<sup>[4](https://www.mmiengineering.com/wp-content/uploads/2014/08/ICE-Paper.pdf)</sup>\n\n## Origin\n\nThe Ronan Point collapse in May 1968 prompted the UK Ministry of Housing and Local Government to issue Circular 62/68, requiring investigation of the susceptibility to progressive collapse of all existing pre-cast load-bearing buildings over 6 storeys.<sup>[5](https://wrap.warwick.ac.uk/id/eprint/117589/1/WRAP-historical-review-prescriptive-design-rules-robustness-collapse-Ronan-Point-Russell-2019.pdf)</sup> That circular described two strategies that still structure the field: providing an alternative load path above a removed wall using arching, beam, or cantilever action, or giving elements a local resistance of 5 psi (34 kN/m2), described as the maximum likely pressure from an explosion in a block of flats.<sup>[5](https://wrap.warwick.ac.uk/id/eprint/117589/1/WRAP-historical-review-prescriptive-design-rules-robustness-collapse-Ronan-Point-Russell-2019.pdf)</sup> Code of Practice 110 in 1972 was one of the earliest national codes to consider progressive collapse, recommending ties placed to resist damage by cantilever, catenary, or other actions.<sup>[5](https://wrap.warwick.ac.uk/id/eprint/117589/1/WRAP-historical-review-prescriptive-design-rules-robustness-collapse-Ronan-Point-Russell-2019.pdf)</sup>\n\nIn the United States, concern predated 2001 because of the Murrah Federal Building bombing, embassy bombings in Africa, and the Marine barracks in Lebanon; a significant result was the creation of [UFC 4](https://www.edgepedia.org/ufc-4)-023-03, Design of Buildings to Resist Progressive Collapse.<sup>[10](https://ascelibrary.com/doi/10.1061/%28ASCE%29ST.1943-541X.0000432)</sup> After the World Trade Center collapse in September 2001, interest among building owners and government entities in evaluating existing buildings rose sharply.<sup>[11](https://ascelibrary.org/doi/10.1061/%28ASCE%290887-3828%282004%2918%3A2%2879%29)</sup> The GSA guidelines were released by the Office of the Chief Architect.<sup>[12](https://www.engr.psu.edu/ae/thesis/portfolios/2008/dsf139/Documents/GSA.pdf)</sup> The DoD research record reports UFC 4-023-03 was first published in January 2005,<sup>[10](https://ascelibrary.com/doi/10.1061/%28ASCE%29ST.1943-541X.0000432)</sup> while the 2009 date corresponds to a revised version.<sup>[5](https://wrap.warwick.ac.uk/id/eprint/117589/1/WRAP-historical-review-prescriptive-design-rules-robustness-collapse-Ronan-Point-Russell-2019.pdf)</sup>\n\n## Variants\n\nTwo basic design means against progressive collapse are the Alternate Path Method, which allows local failure but provides alternate load paths, and the Specific Local Resistance Method.<sup>[13](https://nvlpubs.nist.gov/nistpubs/Legacy/IR/nbsir76-1106.pdf)</sup> A third approach, the tie force method, uses vertical, longitudinal, transverse, and peripheral ties; existing members can serve as ties only if capable of a 0.20 rad (11 degrees) rotation.<sup>[5](https://wrap.warwick.ac.uk/id/eprint/117589/1/WRAP-historical-review-prescriptive-design-rules-robustness-collapse-Ronan-Point-Russell-2019.pdf)</sup> The alternate path method based on column removal scenarios is commonly recommended over the tie force and specific local resistance methods,<sup>[14](https://www.sciencedirect.com/science/article/abs/pii/S0141029620343546)</sup> and the latest GSA guidelines move away from tie force requirements toward alternate load path analysis.<sup>[5](https://wrap.warwick.ac.uk/id/eprint/117589/1/WRAP-historical-review-prescriptive-design-rules-robustness-collapse-Ronan-Point-Russell-2019.pdf)</sup> The SEI Disproportionate Collapse Technical Committee categorizes alternate load path analysis methods into three complexity levels: hand or spreadsheet methods, structural analysis software methods, and advanced numerical modeling.<sup>[6](https://tsapps.nist.gov/publication/get_pdf.cfm?pub_id=922173)</sup>\n\n## Applications\n\nAn analysis produces capacity curves, demand-capacity ratios, and scalar indices that inform the required level of design. Under UFC 4-023-03, the level of progressive collapse design is correlated to the risk category (RC) of the structure; however, that document (2009, Change 4, 10 June 2024) has been archived, and per USACE ECB 2026-7 (23 February 2026), DoD disproportionate collapse design is now based on ASCE 76-23 with guidance in Chapter 8 of [UFC 3](https://www.edgepedia.org/ufc-3)-301-01 (Change 6, 30 January 2026), with projects past 35% design or with an issued Design-Build RFP permitted but not required to adopt the updated criteria.<sup>[15](https://nibs-s3-wbdg3-production.s3.us-east-1.amazonaws.com/FFC/DOD/UFC/ARCHIVES/ufc_4_023_03_2009_c4.pdf)</sup> In pushdown analysis, the load factor \\( \\lambda = \\sum_{i=1}^{n} R_{i} / Q_{tg} \\), where \\( \\sum R_{i} \\) is the sum of the n vertical ground story reaction forces and \\( Q_{tg} \\) is the target load per a preselected load combination; \\( \\lambda < 1 \\) indicates the structure is prone to progressive collapse and \\( \\lambda > 1 \\) indicates residual bearing capacity.<sup>[8](https://iris.unitn.it/retrieve/fccde151-2acc-4ef2-99c2-2f9f646ac871/EFA_Progressive_Collapse_2024_PUBLISHED-compressed.pdf)</sup> A capacity-based robustness metric uses the ultimate capacity of the damaged structural system,<sup>[16](https://pmc.ncbi.nlm.nih.gov/articles/PMC5587139/)</sup> and a robustness index R defined as the minimum normalized ultimate capacity over all considered column removal scenarios reached 1.54 for a 10-story RC example, indicating no collapse under the three removal cases.<sup>[6](https://tsapps.nist.gov/publication/get_pdf.cfm?pub_id=922173)</sup> Applications extend beyond buildings: bridge structures re-equilibrate after sudden column loss through membrane action.<sup>[7](https://www.sciencedirect.com/science/article/pii/S2590123023002177)</sup>\n\n## Limitations and alternatives\n\nStatic procedures carry a known bias. The alternate path method based on static analysis cannot reflect the vital dynamic effects caused by sudden column loss and can indicate overestimated analytical results.<sup>[14](https://www.sciencedirect.com/science/article/abs/pii/S0141029620343546)</sup> [Nonlinear static analysis](https://www.edgepedia.org/nonlinear-static-analysis) reduces this problem with a dynamic amplification factor, but the factor itself reduces the reliability of the response compared with nonlinear dynamic analysis.<sup>[14](https://www.sciencedirect.com/science/article/abs/pii/S0141029620343546)</sup> The linear static procedure may fail to appropriately simulate the inelastic response of a building,<sup>[17](https://onlinelibrary.wiley.com/doi/10.1002/tal.453)</sup> though it gives conservative approximations and minimizes design time.<sup>[4](https://www.mmiengineering.com/wp-content/uploads/2014/08/ICE-Paper.pdf)</sup>\n\nThe dynamic amplification factor is the main calibration problem. A constant DAF of 2.0 was found conservative for estimating the collapse resistance of a ductile column-removed RC building,<sup>[17](https://onlinelibrary.wiley.com/doi/10.1002/tal.453)</sup> yet the dynamic load factor can normally range from 2 for an elastic system under instantaneous column loss to 1 for fire scenarios; Ruth et al. (2006) recommend 1.5 as realistic, and explosive column-removal tests indicate about 1.1 to 1.15 for reinforced concrete frames.<sup>[4](https://www.mmiengineering.com/wp-content/uploads/2014/08/ICE-Paper.pdf)</sup> Recent work derives DIFs numerically by comparing pushdown and dynamic responses for beam- and column-type collapse mechanisms in steel structures.<sup>[8](https://iris.unitn.it/retrieve/fccde151-2acc-4ef2-99c2-2f9f646ac871/EFA_Progressive_Collapse_2024_PUBLISHED-compressed.pdf)</sup> Nonlinear methods capture arching and catenary action but require significant expertise, particularly in modeling beam-to-column connections.<sup>[4](https://www.mmiengineering.com/wp-content/uploads/2014/08/ICE-Paper.pdf)</sup>\n\n## References\n\n1. [GSA Alternate Path Analysis & Design Guidelines for Progressive Collapse Resistance (2016)](https://www.gsa.gov/system/files/Progressive_Collapse_2016.pdf)\n2. [NBS Building Science Series 98: Design methods for reducing the risk of progressive collapse in buildings](https://nvlpubs.nist.gov/nistpubs/Legacy/BSS/nbsbuildingscience98.pdf)\n3. [Assessment of Different Methods for Enhancing Progressive Collapse Resistance of Irregular Reinforced Concrete Buildings Using Pushdown Analysis (Arabian Journal for Science and Engineering, 2024)](https://link.springer.com/article/10.1007/s13369-024-08847-4)\n4. [A review of progressive collapse research and regulations (ICE Proceedings)](https://www.mmiengineering.com/wp-content/uploads/2014/08/ICE-Paper.pdf)\n5. [A historical review of prescriptive design rules for robustness after the Ronan Point collapse](https://wrap.warwick.ac.uk/id/eprint/117589/1/WRAP-historical-review-prescriptive-design-rules-robustness-collapse-Ronan-Point-Russell-2019.pdf)\n6. [Alternative Load Path Analysis of a Reinforced Concrete Frame Building (NIST)](https://tsapps.nist.gov/publication/get_pdf.cfm?pub_id=922173)\n7. [Bridge structures under progressive collapse: A comprehensive state-of-the-art review](https://www.sciencedirect.com/science/article/pii/S2590123023002177)\n8. [Dynamic increase factors for progressive collapse analysis of steel structures considering column buckling (2024)](https://iris.unitn.it/retrieve/fccde151-2acc-4ef2-99c2-2f9f646ac871/EFA_Progressive_Collapse_2024_PUBLISHED-compressed.pdf)\n9. [NIST publication on UFC 4-023-03 acceptance criteria](https://tsapps.nist.gov/publication/get_pdf.cfm?pub_id=922168)\n10. [DoD Research and Criteria for the Design of Buildings to Resist Progressive Collapse](https://ascelibrary.com/doi/10.1061/%28ASCE%29ST.1943-541X.0000432)\n11. [Progressive Analysis Procedure for Progressive Collapse (J. Performance of Constructed Facilities, 2004, 18:2:79)](https://ascelibrary.org/doi/10.1061/%28ASCE%290887-3828%282004%2918%3A2%2879%29)\n12. [GSA Progressive Collapse Analysis and Design Guidelines (2000/2003)](https://www.engr.psu.edu/ae/thesis/portfolios/2008/dsf139/Documents/GSA.pdf)\n13. [Design to reduce the risk of progressive collapse (NBS IR 76-1106)](https://nvlpubs.nist.gov/nistpubs/Legacy/IR/nbsir76-1106.pdf)\n14. [Comparison of progressive collapse resistance capacities of steel ordinary and intermediate moment frames considering different connection details (Engineering Structures)](https://www.sciencedirect.com/science/article/abs/pii/S0141029620343546)\n15. [UFC 4-023-03 Design of Buildings to Resist Progressive Collapse (2009, Change 4 archive)](https://nibs-s3-wbdg3-production.s3.us-east-1.amazonaws.com/FFC/DOD/UFC/ARCHIVES/ufc_4_023_03_2009_c4.pdf)\n16. [Evaluation of Structural Robustness against Column Loss: Methodology and Application to RC Frame Buildings](https://pmc.ncbi.nlm.nih.gov/articles/PMC5587139/)\n17. [Dynamic amplification factor for progressive collapse resistance analysis of an RC building (Lin, 2008, The Structural Design of Tall and Special Buildings)](https://onlinelibrary.wiley.com/doi/10.1002/tal.453)\n\n---\n*Topic: Encyclopedia › Technology and the built world › Architecture, buildings, and civil works*\n\n*Initially written Sep 29, 2026 · Reviewed: Sep 30, 2026 · Edited: Oct 15, 2026 · Last review: Sep 30, 2026*\n\n*Copyright 2026 EdgeChat AI, a subsidiary of Biostate AI.*\n\nLicense: Edgepedia Community License 1.0, https://www.edgepedia.org/edgepedia/license\n",
 "same_as": [],
 "url": "https://www.edgepedia.org/progressive-collapse-analysis",
 "markdown_url": "https://www.edgepedia.org/progressive-collapse-analysis.md",
 "license": {
  "name": "Edgepedia Community License 1.0",
  "url": "https://www.edgepedia.org/edgepedia/license",
  "summary": "Free with credit, commercial use included. AI training is open to everyone. For other uses, organizations over USD 100M in revenue or 100M monthly users license separately.",
  "spdx": "LicenseRef-Edgepedia-Community-1.0"
 },
 "credit": "\"Progressive collapse analysis\", Edgepedia (EdgeChat), https://www.edgepedia.org/progressive-collapse-analysis. Edgepedia Community License 1.0.",
 "credit_md": "\"[Progressive collapse analysis](https://www.edgepedia.org/progressive-collapse-analysis)\", Edgepedia (EdgeChat), [https://www.edgepedia.org/progressive-collapse-analysis](https://www.edgepedia.org/progressive-collapse-analysis). [Edgepedia Community License 1.0](https://www.edgepedia.org/edgepedia/license).",
 "credit_html": "\"<a href=\"https://www.edgepedia.org/progressive-collapse-analysis\">Progressive collapse analysis</a>\", Edgepedia (EdgeChat), <a href=\"https://www.edgepedia.org/progressive-collapse-analysis\">https://www.edgepedia.org/progressive-collapse-analysis</a>. <a href=\"https://www.edgepedia.org/edgepedia/license\">Edgepedia Community License 1.0</a>.",
 "speakable": "Progressive collapse analysis is a structural engineering method that checks whether a building can absorb local damage, such as losing a column, without disproportionate collapse."
}