# Johnson–Nyquist noise

**Johnson–Nyquist noise** (also called Johnson noise or thermal noise) is the electrical noise generated by the random thermal motion of charge carriers in any [electrical conductor](https://www.edgepedia.org/electrical-conductor), appearing as a fluctuating voltage across the conductor's terminals even when no current flows. John B. Johnson first measured the effect at Bell Laboratories, and [Harry Nyquist](https://www.edgepedia.org/harry-nyquist) derived its quantitative law in 1928; the noise power depends only on temperature, resistance, and bandwidth, not on the material or shape of the conductor.<sup>[1](https://technav.ieee.org/topic/thermal-noise/)</sup><sup> • </sup><sup>[2](https://tsapps.nist.gov/publication/get_pdf.cfm?pub_id=956180)</sup>

| Key fact | Detail |
|---|---|
| Definition | Voltage noise from thermal agitation of charge carriers in any conductor above absolute zero; also called Nyquist noise<sup>[2](https://tsapps.nist.gov/publication/get_pdf.cfm?pub_id=956180)</sup> |
| Classical law | Mean-square noise voltage \( \langle V^2 \rangle = 4kTR\,\Delta f \), with spectral density \( S_v = 4kTR \) in V²/Hz, independent of frequency (white noise)<sup>[3](https://nvlpubs.nist.gov/nistpubs/Legacy/SP/nbsspecialpublication614.pdf)</sup> |
| Quantum form | \( S(f) = 4\,\mathrm{Re}(Z)\,hf/(e^{hf/kT} - 1) \), a one-dimensional form of the Planck blackbody law<sup>[2](https://tsapps.nist.gov/publication/get_pdf.cfm?pub_id=956180)</sup> |
| Typical size | About 4 nV/√Hz for a 1 kΩ resistor at room temperature; about 4 μV rms over a 1 MHz bandwidth<sup>[4](https://doi.org/10.1088/1681-7575/ad2273)</sup> |
| Available power | A matched resistor delivers noise power \( kTB \) into a load over bandwidth \( B \)<sup>[5](https://casper.berkeley.edu/astrobaki/index.php/Johnson_Noise)</sup> |
| Discovery | Measured by J. B. Johnson (definitive measurements 1928); derived by H. Nyquist, Phys. Rev. 32, 110 (1 July 1928)<sup>[2](https://tsapps.nist.gov/publication/get_pdf.cfm?pub_id=956180)</sup><sup> • </sup><sup>[6](https://doi.org/10.1103/physrev.32.110)</sup> |
| Metrological use | Johnson noise thermometry is one of five primary thermometer types recognized by the Consultative Committee for Thermometry; it contributed to the 2019 redefinition of the kelvin<sup>[4](https://doi.org/10.1088/1681-7575/ad2273)</sup> |

## Discovery

Johnson, working at Bell Laboratories, first measured the open-circuit noise voltage of a resistor in 1926 and found it independent of the material and of frequency, depending only on the resistance and the temperature.<sup>[1](https://technav.ieee.org/topic/thermal-noise/)</sup><sup> • </sup><sup>[7](https://www.eng.auburn.edu/~niuguof/research/noise.html)</sup> He described the phenomenon in two short notes in 1927 (Nature, 8 January 1927, and [Physical Review](https://www.edgepedia.org/physical-review) 29, 367, February 1927), then published the full account, "Thermal Agitation of Electricity in Conductors," in Physical Review volume 32, pages 97–109, in July 1928.<sup>[2](https://tsapps.nist.gov/publication/get_pdf.cfm?pub_id=956180)</sup><sup> • </sup><sup>[8](https://www.scienceopen.com/document?vid=a016e38e-a521-4758-add1-70a713e141ef)</sup> In that paper Johnson reported the charges in a conductor to be in a state of thermal agitation, in thermodynamic equilibrium with the heat motion of the atoms, and gave the measured effect as \( \overline{I^2} = (2kT/\pi)\int_0^\infty R(\omega)\,|Y(\omega)|^2\,d\omega \), where \( R(\omega) \) is the real part of the conductor's impedance and \( Y(\omega) \) the transfer impedance of his measuring amplifier.<sup>[8](https://www.scienceopen.com/document?vid=a016e38e-a521-4758-add1-70a713e141ef)</sup> The Boltzmann constant he extracted from the measurements lay near the accepted value.<sup>[8](https://www.scienceopen.com/document?vid=a016e38e-a521-4758-add1-70a713e141ef)</sup>

Nyquist, of the American Telephone and Telegraph Company, supplied the theory a few months later in "Thermal Agitation of Electric Charge in Conductors" (Physical Review 32, 110, published 1 July 1928, received 1 April 1928), calculating the electromotive force from thermodynamics and statistical mechanics and obtaining results that agreed with Johnson's measurements.<sup>[6](https://doi.org/10.1103/physrev.32.110)</sup> His argument counted the modes of vibration of charge on a transmission line and applied the equipartition law, assigning an average energy \( kT \) to each degree of freedom.<sup>[9](https://123.physics.ucdavis.edu/johnson_files/nyquist_1928.pdf)</sup>

The attribution has a longer prehistory. Although the discovery is generally credited to Johnson and Nyquist, the noise was predicted by [Albert Einstein](https://www.edgepedia.org/albert-einstein) in his 1905 explanation of [Brownian motion](https://www.edgepedia.org/brownian-motion), more than two decades earlier; Johnson noise and Brownian motion are both cases in which microscopic random thermal motions produce macroscopic dissipative effects, a relationship formalized as the fluctuation–dissipation theorem by Callen and Welton in 1951.<sup>[2](https://tsapps.nist.gov/publication/get_pdf.cfm?pub_id=956180)</sup>

## The Nyquist formula

The noise-voltage power spectral density across an unloaded resistor of resistance \( R \) at absolute temperature \( T \) is<sup>[3](https://nvlpubs.nist.gov/nistpubs/Legacy/SP/nbsspecialpublication614.pdf)</sup>

\[ S_v = \frac{4hfR}{\exp(hf/kT) - 1} \]

in V²/Hz, where \( h \) is Planck's constant and \( f \) the frequency in Hz. This expression, derived by Nyquist, is the one-dimensional form of the Planck blackbody law.<sup>[2](https://tsapps.nist.gov/publication/get_pdf.cfm?pub_id=956180)</sup> At ordinary frequencies the photon energy is negligible compared with \( kT \): the crossover frequency \( kT/h \) is 6.25 GHz at \( T = 300 \) K, so the classical limit applies well below that.<sup>[3](https://nvlpubs.nist.gov/nistpubs/Legacy/SP/nbsspecialpublication614.pdf)</sup> There the formula reduces to **Nyquist's law**,<sup>[3](https://nvlpubs.nist.gov/nistpubs/Legacy/SP/nbsspecialpublication614.pdf)</sup>

\[ \langle V_T^2 \rangle = 4kT\,\mathrm{Re}(Z)\,\Delta f \]

where \( \Delta f \) is the measurement bandwidth and \( \mathrm{Re}(Z) \) the real (resistive) part of the impedance. For a pure resistance the spectral density \( S_v = 4kTR \) is flat, so the noise is described as white.<sup>[4](https://doi.org/10.1088/1681-7575/ad2273)</sup> An equivalent circuit model places a noise voltage generator \( \sqrt{4kTR} \) in series with an ideal noiseless resistor; alternatively, a noise current generator with spectral density \( S_I = 4kT/R \) sits in parallel with the resistor.<sup>[3](https://nvlpubs.nist.gov/nistpubs/Legacy/SP/nbsspecialpublication614.pdf)</sup>

The power delivered matters as much as the voltage. By the [maximum power transfer theorem](https://www.edgepedia.org/maximum-power-transfer-theorem), a source of resistance \( R \) delivers its full available noise power only to a matched load, where the voltage divides by two; the available power per unit bandwidth is then<sup>[5](https://casper.berkeley.edu/astrobaki/index.php/Johnson_Noise)</sup>

\[ \frac{P}{B} = kT \]

which is why a resistive source at temperature \( T \) is said to add a noise temperature \( T \) to a receiver.<sup>[5](https://casper.berkeley.edu/astrobaki/index.php/Johnson_Noise)</sup>

**Quantum regime.** At high frequencies or very low temperatures the classical approximation fails. The relative error of Nyquist's law follows from the series expansion of the Planck factor, \( 1 - hf/(2kT) + \ldots \approx 1 - 2.4 \times 10^{-11}\,f/T \); a thermometer using Nyquist's law near 1 mK with an average operating frequency of 100 kHz is accurate to about 0.24%.<sup>[4](https://doi.org/10.1088/1681-7575/ad2273)</sup> A term representing quantum-mechanical zero-point energy is often added to the exact formula, but its inclusion is controversial because it makes the integrated noise power over all frequencies unbounded; the most recent view, supported by experiment and analogy with the [Casimir effect](https://www.edgepedia.org/casimir-effect), is that the term is not manifest in mechanically stable macroscopic systems and should be omitted.<sup>[4](https://doi.org/10.1088/1681-7575/ad2273)</sup>

## Magnitude and practical consequences

The noise is small but unavoidable. A convenient rule of thumb is that a 1 kΩ resistor at room temperature produces a spectral density of about 4 nV/√Hz, and integrated over a 1 MHz bandwidth the noise totals about 4 μV rms.<sup>[4](https://doi.org/10.1088/1681-7575/ad2273)</sup> Equivalently, a resistor at 290 K generates approximately 4 nV/√Hz per kiloohm of resistance.<sup>[1](https://technav.ieee.org/topic/thermal-noise/)</sup> Johnson's own 1928 measurements, made with a vacuum tube amplifier and thermocouple over a 5000-cycle range, gave a power equivalent of \( \overline{V^2}/R = 0.8 \times 10^{-16} \) watt for an input resistance \( R \).<sup>[8](https://www.scienceopen.com/document?vid=a016e38e-a521-4758-add1-70a713e141ef)</sup>

Because every resistive element generates the noise, thermal noise sets a fundamental lower bound on signal detectability in electronic circuits; it cannot be eliminated, only reduced by cooling or by restricting bandwidth.<sup>[1](https://technav.ieee.org/topic/thermal-noise/)</sup> Only the resistive component contributes: an ideal purely reactive inductor or capacitor generates no thermal noise.<sup>[1](https://technav.ieee.org/topic/thermal-noise/)</sup> [Low-noise amplifier](https://www.edgepedia.org/low-noise-amplifier) design therefore favors low-resistance input stages and cooling of the first amplification element, where the signal is weakest.<sup>[1](https://technav.ieee.org/topic/thermal-noise/)</sup> In Johnson's day the effect was already recognized as often the largest part of the "tube noise" of a good vacuum tube amplifier, heard as a steady rustling in a telephone receiver.<sup>[8](https://www.scienceopen.com/document?vid=a016e38e-a521-4758-add1-70a713e141ef)</sup>

## Johnson noise thermometry

Because the noise voltage is directly proportional to temperature, measuring it yields a thermometer that needs no calibration against other temperature sensors: so long as the sensor resistance can be measured, Nyquist's law is insensitive to chemical, mechanical, and even nuclear changes in the sensor.<sup>[10](https://pmc.ncbi.nlm.nih.gov/articles/PMC11194799/)</sup> Noise thermometry has been applied at temperatures ranging from below 50 nK to 2200 °C, a range exceeding that of any other temperature sensor, and sensors need not be metallic; electrolytic solutions, graphite rope, and combustion plasma have all been used.<sup>[10](https://pmc.ncbi.nlm.nih.gov/articles/PMC11194799/)</sup> The drawbacks are the faintness of the signal, which must be amplified by a factor of \( 10^5 \) or more, and the slow convergence of the statistical uncertainty, which decreases only as the square root of bandwidth times measurement time.<sup>[10](https://pmc.ncbi.nlm.nih.gov/articles/PMC11194799/)</sup>

**Primary thermometry and the kelvin.** In primary Johnson noise thermometry (JNT), the temperature is inferred by comparing the Johnson noise voltage of a resistor at the unknown temperature with pseudo-random noise synthesized by a quantum-based voltage noise source (QVNS), a superconducting Josephson-junction array whose output amplitude is set by multiples of the [Planck constant](https://www.edgepedia.org/planck-constant).<sup>[4](https://doi.org/10.1088/1681-7575/ad2273)</sup><sup> • </sup><sup>[11](https://www.nist.gov/programs-projects/johnson-noise-thermometry)</sup> The measurement thus determines the ratio \( k/h \) of the [Boltzmann constant](https://www.edgepedia.org/boltzmann-constant) to the Planck constant.<sup>[12](https://www.nist.gov/news-events/news/2016/11/noise-temperature-and-new-si)</sup> This capability supported the 2019 redefinition of the kelvin, in which the SI unit of temperature is defined by fixing the value of the Boltzmann constant; JNT was valued because it rests on a physics and technology different from the acoustic gas thermometry that produced the best authoritative values of \( k \).<sup>[10](https://pmc.ncbi.nlm.nih.gov/articles/PMC11194799/)</sup><sup> • </sup><sup>[12](https://www.nist.gov/news-events/news/2016/11/noise-temperature-and-new-si)</sup>

The leading determinations of \( k \) by JNT reached relative uncertainties of \( 2.7 \times 10^{-6} \) at the National Institute of Metrology (NIM, China) in 2017, \( 5.0 \times 10^{-6} \) at NIST, and \( 1.0 \times 10^{-5} \) at the [National Metrology Institute of Japan](https://www.edgepedia.org/national-metrology-institute-of-japan).<sup>[2](https://tsapps.nist.gov/publication/get_pdf.cfm?pub_id=956180)</sup> Current best practice with the switched-correlator and QVNS method achieves an uncertainty of about 1 mK near 300 K and operates between 4 K and 700 K.<sup>[13](https://www.nist.gov/publications/practical-realisation-kelvin-johnson-noise-thermometry)</sup> Beyond metrology, the sensor's immunity to material change suits JNT to industrial settings where conventional sensors cannot be withdrawn for recalibration, such as the nuclear power industry.<sup>[10](https://pmc.ncbi.nlm.nih.gov/articles/PMC11194799/)</sup>

## References

1. [Thermal noise, IEEE Technology Navigator](https://technav.ieee.org/topic/thermal-noise/)
2. [Benz, S. P. et al. (2024). Practical realisation of the kelvin by Johnson noise thermometry (PDF), Metrologia 61, 022001](https://tsapps.nist.gov/publication/get_pdf.cfm?pub_id=956180)
3. [Blalock, T. V. & Shepard, R. L. Survey, Applications, and Prospects of Johnson Noise Thermometry, NIST Special Publication 614](https://nvlpubs.nist.gov/nistpubs/Legacy/SP/nbsspecialpublication614.pdf)
4. [Benz, S. P. et al. (2024). Practical realisation of the kelvin by Johnson noise thermometry, Metrologia 61, 022001](https://doi.org/10.1088/1681-7575/ad2273)
5. [Johnson-Nyquist Noise, AstroBaki (CASPER, UC Berkeley)](https://casper.berkeley.edu/astrobaki/index.php/Johnson_Noise)
6. [Nyquist, H. (1928). Thermal Agitation of Electric Charge in Conductors, Physical Review 32, 110](https://doi.org/10.1103/physrev.32.110)
7. [Noise, Guofu Niu, Auburn University](https://www.eng.auburn.edu/~niuguof/research/noise.html)
8. [Johnson, J. B. (1928). Thermal Agitation of Electricity in Conductors, Physical Review 32, 97–109](https://www.scienceopen.com/document?vid=a016e38e-a521-4758-add1-70a713e141ef)
9. [Nyquist, H. (1928). Thermal Agitation of Electric Charge in Conductors (PDF), UC Davis](https://123.physics.ucdavis.edu/johnson_files/nyquist_1928.pdf)
10. [White, D. R. et al. Johnson Noise Thermometry, PMC](https://pmc.ncbi.nlm.nih.gov/articles/PMC11194799/)
11. [Johnson Noise Thermometry, NIST](https://www.nist.gov/programs-projects/johnson-noise-thermometry)
12. [Noise, Temperature, and the New SI, NIST (2016)](https://www.nist.gov/news-events/news/2016/11/noise-temperature-and-new-si)
13. [Practical realisation of the kelvin by Johnson noise thermometry, NIST publications](https://www.nist.gov/publications/practical-realisation-kelvin-johnson-noise-thermometry)

---
*Initially written Sep 17, 2026 · Reviewed: Oct 15, 2026 · Edited: Oct 15, 2026; Oct 25, 2026 · Last review: Oct 15, 2026*

Topic: Physical world and mathematics › Physics › Classical physics › Thermodynamics › Statistical mechanics and kinetic theory › Fluctuations, Brownian motion, and noise

Copyright 2026 Edgepedia

License: Edgepedia Community License 1.0, https://www.edgepedia.org/edgepedia/license

Source: https://www.edgepedia.org/johnson-nyquist-noise