# Mach–Zehnder interferometer

The Mach–Zehnder interferometer (MZI) is an optical instrument that splits a coherent light beam into two separate paths, allows each path to accumulate a different phase shift, and then recombines the beams to produce an interference pattern whose intensity encodes the phase difference.<sup>[1](https://technav.ieee.org/topic/mach-zehnder-interferometers/)</sup> It was first described by Ludwig Zehnder in 1891 and refined by Ludwig Mach in 1892, and it is now used in flow visualization, refractive-index sensing, optical communications, and as a standard apparatus for tests of quantum complementarity.<sup>[2](https://www.researchgate.net/publication/313738879_The_Interferometers_of_Zehnder_and_Mach)</sup><sup> • </sup><sup>[3](https://www.tau.ac.il/~phchlab/exp-interferometry-theory.html)</sup>

| Key fact | Detail |
|---|---|
| Inventors | Ludwig Zehnder, "Ein neuer Interferenzrefraktor," *Zeitschrift für Instrumentenkunde* 11, 275–285 (1891); Ludwig Mach, "Ueber einen Interferenzrefraktor," *Zeitschrift für Instrumentenkunde* 12, 89–93 (1892)<sup>[2](https://www.researchgate.net/publication/313738879_The_Interferometers_of_Zehnder_and_Mach)</sup> |
| Output relation | With 50/50 beam splitters, the two output powers vary as \( (P_{\mathrm{in}}/2)[1 \mp \cos(\Delta\phi)] \), where \( \Delta\phi \) is the phase difference between the arms; total output power equals input power<sup>[4](https://ocw.mit.edu/courses/6-974-fundamentals-of-photonics-quantum-electronics-spring-2006/8e54d1625e9e71eb5b4e4998e6967e4e_chapter2.pdf)</sup> |
| Operating bias | Interferometers are often biased at a \( \pi/2 \) phase difference, where the intensity change per unit phase shift is greatest<sup>[5](https://stax.strath.ac.uk/downloads/s1784m12w?locale=en)</sup> |
| Coherence requirement | Interference between the arms is observable only while the path difference is shorter than the source's coherence length<sup>[3](https://www.tau.ac.il/~phchlab/exp-interferometry-theory.html)</sup> |
| Distinction from Michelson | Each separated path is traversed only once, and the device has two complementary outputs differing by a \( \pi \) phase shift, rather than a single output<sup>[3](https://www.tau.ac.il/~phchlab/exp-interferometry-theory.html)</sup> |
| Sensing resolution | An in-fiber MZI measured the refractive indices of nine monoatomic and molecular gases with a resolution of \( \delta n < 10^{-6} \)<sup>[6](https://openalex.org/W2420492454)</sup> |
| Quantum reach | Stable single-photon interference has been demonstrated in a 1 km fiber-optical MZI with a net visibility of 0.97<sup>[7](https://arxiv.org/abs/1104.2866)</sup> |

## Working principle

A Mach–Zehnder interferometer consists of two beam splitters and two mirrors. A beam splitter oriented at 45 degrees to the incoming beam divides the light into two beams of equal intensity; mirrors direct the beams along the two arms, and a second beam splitter recombines them at two output ports feeding detectors.<sup>[3](https://www.tau.ac.il/~phchlab/exp-interferometry-theory.html)</sup> Each reflection from a beam splitter or mirror introduces a \( \pi \) phase shift to the electromagnetic wave, and the difference in optical path between the arms, whether from a difference in distance traveled or from a sample placed in one arm, determines the output at the detectors.<sup>[3](https://www.tau.ac.il/~phchlab/exp-interferometry-theory.html)</sup>

The classical analysis treats the beam splitters as lossless four-port devices. For a 50/50 splitter excited at one input port with amplitude \( a_0 \), the two arms carry waves that pick up phase delays \( \phi_3 = kL_3 \) and \( \phi_4 = kL_4 \). After the second beam splitter, the output powers are<sup>[4](https://ocw.mit.edu/courses/6-974-fundamentals-of-photonics-quantum-electronics-spring-2006/8e54d1625e9e71eb5b4e4998e6967e4e_chapter2.pdf)</sup>

\[
|b_7|^2 = \frac{|a_0|^2}{2}\left[1 - \cos(\phi_3 - \phi_4)\right], \qquad
|b_8|^2 = \frac{|a_0|^2}{2}\left[1 + \cos(\phi_3 - \phi_4)\right].
\]

The total output power equals the input power, as required for a lossless system, but the power is split between the two ports according to the phase difference \( \Delta\phi = \phi_3 - \phi_4 \).<sup>[4](https://ocw.mit.edu/courses/6-974-fundamentals-of-photonics-quantum-electronics-spring-2006/8e54d1625e9e71eb5b4e4998e6967e4e_chapter2.pdf)</sup> If the optical paths of the two arms are equal, one detector receives fully constructive interference and the other receives fully destructive interference; in practice exact balance is hard to obtain because of finite accuracy in positioning and alignment, but the two detectors always show complementary outputs separated by a \( \pi \) phase shift.<sup>[3](https://www.tau.ac.il/~phchlab/exp-interferometry-theory.html)</sup>

**Bias point.** The slope of the cosine transfer function is zero at \( \Delta\phi = 0 \) and \( \pi \), so interferometers are often biased with a \( \pi/2 \) phase shift, where any perturbation \( \Delta\phi \) produces the greatest change in output intensity; with this bias the difference in output power between the two ports becomes directly proportional to the phase difference.<sup>[5](https://stax.strath.ac.uk/downloads/s1784m12w?locale=en)</sup><sup> • </sup><sup>[4](https://ocw.mit.edu/courses/6-974-fundamentals-of-photonics-quantum-electronics-spring-2006/8e54d1625e9e71eb5b4e4998e6967e4e_chapter2.pdf)</sup> Because the phase difference between the arms depends on frequency, the device also acts as a filter, though a two-beam interference filter is not very sharp compared with multipass devices such as the Fabry–Pérot resonator.<sup>[4](https://ocw.mit.edu/courses/6-974-fundamentals-of-photonics-quantum-electronics-spring-2006/8e54d1625e9e71eb5b4e4998e6967e4e_chapter2.pdf)</sup>

## History

Ludwig Zehnder (1854–1949) published "Ein neuer Interferenzrefraktor" in Berlin through the publisher [Julius Springer](https://www.edgepedia.org/julius-springer) in 1891, and Ludwig Mach described a refined version, "Ueber einen Interferenzrefraktor," in *Zeitschrift für Instrumentenkunde* 12, 89–93 (1892).<sup>[2](https://www.researchgate.net/publication/313738879_The_Interferometers_of_Zehnder_and_Mach)</sup><sup> • </sup><sup>[8](https://www.e-rara.ch/zut/doi/10.3931/e-rara-76749?lang=en)</sup> The instrument was conceived as an interference refractometer, a device for measuring refractive index, and that purpose still defines many of its uses.<sup>[8](https://www.e-rara.ch/zut/doi/10.3931/e-rara-76749?lang=en)</sup>

## Flow visualization and refractometry

The Mach–Zehnder interferometer is a classical method of flow visualization in aerodynamics: one arm passes through a test section while the reference arm bypasses it, so density changes in the flow shift the interference fringes.<sup>[9](https://ntrs.nasa.gov/api/citations/19780007115/downloads/19780007115.pdf)</sup> NASA notes that these instruments are seldom used for wind tunnel calibration because of their cost and their hypersensitivity to vibration and alignment errors.<sup>[9](https://ntrs.nasa.gov/api/citations/19780007115/downloads/19780007115.pdf)</sup> Modified configurations address these limits: a 1979 NASA contractor report described a self-synchronizing stroboscopic laser interferometer with a modified Mach–Zehnder optical system for visualizing unsteady transonic flows, and a later scheme placed a small modified MZI in series with a much larger schlieren system so that the object and reference beams are separated only over a short interval, greatly reducing differential vibrations.<sup>[10](https://ntrs.nasa.gov/citations/19810023929)</sup><sup> • </sup><sup>[11](https://ntrs.nasa.gov/api/citations/19820024794/downloads/19820024794.pdf)</sup>

Because the light passes through the sample only once, the path difference introduced by a sample of thickness \( d \) and index contrast \( \Delta n \) is \( l = d \cdot \Delta n \), with no factor of two to divide out.<sup>[3](https://www.tau.ac.il/~phchlab/exp-interferometry-theory.html)</sup> This single-pass geometry underlies refractometry. Fiber implementations push the sensitivity further: an in-fiber MZI built from hollow-core photonic crystal fiber measured the refractive indices of nine monoatomic and molecular gases with a resolution of \( \delta n < 10^{-6} \),<sup>[6](https://openalex.org/W2420492454)</sup> and capillary-based and tapered-fiber MZI sensors are used for gas refractive-index and chemical sensing.<sup>[12](https://orbi.umons.ac.be/handle/20.500.12907/51010)</sup><sup> • </sup><sup>[13](https://pmc.ncbi.nlm.nih.gov/articles/PMC6480093/)</sup> [Silicon nitride](https://www.edgepedia.org/silicon-nitride) integrated MZIs have been demonstrated that measure the complex refractive index directly, giving both refraction and absorption.<sup>[14](https://arxiv.org/abs/2405.14328)</sup>

## Integrated photonics and modulators

In integrated optics the MZI becomes the [Mach–Zehnder modulator](https://www.edgepedia.org/mach-zehnder-modulator) (MZM). The optical carrier is split into two waveguides, phase modulation is applied in the arms, and the signals are recombined; depending on the relative phase position, the partial signals overlap to form the modulated output.<sup>[15](https://www.int.uni-stuttgart.de/en/research/photonics/modulators/)</sup> In silicon-on-insulator technology the phase shift is produced by the plasma dispersion effect, in which an applied electric field shifts free charge carriers in a doped rib waveguide, changing the refractive index and thus the phase velocity of the light.<sup>[15](https://www.int.uni-stuttgart.de/en/research/photonics/modulators/)</sup> [Lithium niobate](https://www.edgepedia.org/lithium-niobate) (LiNbO\(_3\)) is another standard platform, where the electro-optic effect changes the refractive index under an applied voltage; such modulators support optical links at 2.5 Gb/s and above, where direct laser modulation no longer suffices.<sup>[16](https://antena.fe.uni-lj.si/studij/vaje/linbo3_elektroopticni_amplitudni_modulator/)</sup> A fiber-coupled MZM works the same way in free space or waveguide form: a 50:50 coupler splits the light, electrodes drive phase changes in an electro-optic material, and a second coupler recombines the paths so that the accumulated phase difference dictates the relative intensity leaving each output port.<sup>[17](https://curj.caltech.edu/2019/09/03/stabilization-of-an-electro-optic-modulator-for-quantum-communication-using-a-low-cost-microcontroller/)</sup>

Reported device metrics show the design space. A monolithically integrated indium tin oxide (ITO) MZI modulator achieved a half-wave voltage and active length product of \( V_{\pi}L = 0.52 \) V·mm,<sup>[18](https://arxiv.org/abs/1809.03544)</sup> a ring-assisted lithium niobate MZI modulator reached a spurious-free dynamic range of 120.04 dB Hz\(^{4/5}\) at 1 GHz,<sup>[19](https://arxiv.org/abs/2202.12739)</sup> and a visible-near-infrared MZI on lithium niobate on sapphire operated at 780 nm with a full-swing voltage of 4.2 V, an electro-optic bandwidth of 2.7 GHz, and an area of only 0.35 mm\(^2\).<sup>[20](https://arxiv.org/abs/2204.03138)</sup>

## Quantum interference and complementarity

The MZI is the standard single-photon realization of wave–particle duality. A single photon entering the first beam splitter is placed into a superposition of the two paths, and interference appears in the output statistics even when photons pass through one at a time.<sup>[21](https://academic.oup.com/book/26679/chapter-abstract/195457642)</sup> Single-photon MZI experiments are used both in research and in teaching laboratories; a 1987 experiment by Franson checked single-photon interference in a 45 m long Mach–Zehnder interferometer,<sup>[22](https://quantumlab.nat.uni-erlangen.de/english/interference/Photon/index.html)</sup> and a test at NIST of an event-based corpuscular model as an alternative to quantum mechanics found that the single-photon MZI results agreed with the predictions of standard quantum mechanics.<sup>[23](https://www.nist.gov/publications/practical-implementation-test-event-based-corpuscular-model-alternative-quantum)</sup>

**Complementarity.** The MZI makes Bohr's complementarity principle concrete: observing interference (the wave aspect) and obtaining which-way information (the particle aspect) are mutually exclusive in any interference experiment.<sup>[24](https://doi.org/10.1140/epjc/s10052-021-09740-2)</sup> A detailed analysis by Paul Busch, a philosopher-theoretical physicist of the Foundations of Physics group, and Christopher R. Shilladay showed that path detection via entanglement with a probe system and quantitative quantum erasure are instances of joint unsharp measurements of the complementary path and interference observables, analyzed with positive-operator-valued measures (POVMs); complementarity, the mutual exclusivity of path detection and interference observation, is recovered as a limit case of the appropriate uncertainty relation.<sup>[25](https://arxiv.org/abs/quant-ph/0609048)</sup> Quantum eraser demonstrations with single photons in an MZI show the interference fringes disappearing when which-path information is tagged and returning when it is erased.<sup>[26](https://folia.unifr.ch/unifr/documents/301524)</sup>

**Scale.** Fiber MZIs extend single-photon interference to long baselines: stable, user-adjustable single-photon interference has been demonstrated in a 1 km fiber-optical MZI using active phase control with feedback from a classical laser, achieving a net visibility of 0.97,<sup>[7](https://arxiv.org/abs/1104.2866)</sup> and a 50 km table-top fiber MZI operating at the single-photon level has been reported for tests of gravitational signatures in quantum interference, with phase sensitivity within the 0.01–5 Hz frequency range.<sup>[27](https://journals.aps.org/prl/abstract/10.1103/yvlk-t1j9)</sup>

## References

1. [Mach-Zehnder interferometers, IEEE Technology Navigator](https://technav.ieee.org/topic/mach-zehnder-interferometers/)
2. [The Interferometers of Zehnder and Mach, C. W. Clark (ed.), 2017](https://www.researchgate.net/publication/313738879_The_Interferometers_of_Zehnder_and_Mach)
3. [Chemical Physics laboratory notes, Tel Aviv University](https://www.tau.ac.il/~phchlab/exp-interferometry-theory.html)
4. [Fundamentals of Photonics, Quantum Electronics course notes, MIT OpenCourseWare](https://ocw.mit.edu/courses/6-974-fundamentals-of-photonics-quantum-electronics-spring-2006/8e54d1625e9e71eb5b4e4998e6967e4e_chapter2.pdf)
5. [Optical interferometry notes, University of Strathclyde](https://stax.strath.ac.uk/downloads/s1784m12w?locale=en)
6. [In-fiber Mach-Zehnder interferometer for gas refractive index measurements based on a hollow-core photonic crystal fiber, Optics Express](https://openalex.org/W2420492454)
7. [Stable single-photon interference in a 1 km fiber-optical Mach-Zehnder interferometer with continuous phase adjustment, arXiv](https://arxiv.org/abs/1104.2866)
8. [Zehnder, Ludwig: Ein neuer Interferenzrefraktor, ETH-Bibliothek Zürich](https://www.e-rara.ch/zut/doi/10.3931/e-rara-76749?lang=en)
9. [Optical methods for wind tunnel testing, NASA Technical Reports](https://ntrs.nasa.gov/api/citations/19780007115/downloads/19780007115.pdf)
10. [Self-synchronizing Schlieren photography and interferometry for the visualization of unsteady transonic flows, NASA CR-164839](https://ntrs.nasa.gov/citations/19810023929)
11. [New versions of old flow visualization, NASA Technical Reports](https://ntrs.nasa.gov/api/citations/19820024794/downloads/19820024794.pdf)
12. [Ultrasensitive gas refractometer using capillary-based Mach-Zehnder interferometer, ORBi UMONS](https://orbi.umons.ac.be/handle/20.500.12907/51010)
13. [Tapered fiber-optic Mach-Zehnder interferometer for ultra-high sensitivity measurement of refractive index, PMC](https://pmc.ncbi.nlm.nih.gov/articles/PMC6480093/)
14. [Simultaneous measurement of refraction and absorption with an integrated near-infrared Mach-Zehnder interferometer, arXiv](https://arxiv.org/abs/2405.14328)
15. [Electro-optical modulators, Institute of Electrical and Optical Communications, University of Stuttgart](https://www.int.uni-stuttgart.de/en/research/photonics/modulators/)
16. [LiNbO3 elektrooptični amplitudni modulator, University of Ljubljana](https://antena.fe.uni-lj.si/studij/vaje/linbo3_elektroopticni_amplitudni_modulator/)
17. [Stabilization of an electro-optic modulator for quantum communication using a low-cost microcontroller, Caltech Undergraduate Research Journal](https://curj.caltech.edu/2019/09/03/stabilization-of-an-electro-optic-modulator-for-quantum-communication-using-a-low-cost-microcontroller/)
18. [0.52 V·mm ITO-based Mach-Zehnder modulator in silicon photonics, arXiv](https://arxiv.org/abs/1809.03544)
19. [Ultra-high-linearity integrated lithium niobate electro-optic modulators, arXiv](https://arxiv.org/abs/2202.12739)
20. [High-bandwidth CMOS-voltage-level electro-optic modulation of 780 nm light in thin-film lithium niobate, arXiv](https://arxiv.org/abs/2204.03138)
21. [The Mach–Zehnder Interferometer, in *Quantum Weirdness*, Oxford Academic](https://academic.oup.com/book/26679/chapter-abstract/195457642)
22. [Single photon interferometer, QuantumLab, Universität Erlangen-Nürnberg](https://quantumlab.nat.uni-erlangen.de/english/interference/Photon/index.html)
23. [Practical implementation of a test of event-based corpuscular model as an alternative to quantum mechanics, NIST](https://www.nist.gov/publications/practical-implementation-test-event-based-corpuscular-model-alternative-quantum)
24. [Quantum interference in external gravitational fields beyond General Relativity, European Physical Journal C](https://doi.org/10.1140/epjc/s10052-021-09740-2)
25. [Busch, P. and Shilladay, C. R., Complementarity and Uncertainty in Mach-Zehnder Interferometry and beyond, arXiv](https://arxiv.org/abs/quant-ph/0609048)
26. [Single photon quantum erasing: a demonstration experiment, FOLIA University of Fribourg](https://folia.unifr.ch/unifr/documents/301524)
27. [50-km fiber interferometer for testing gravitational signatures in quantum interference, Physical Review Letters](https://journals.aps.org/prl/abstract/10.1103/yvlk-t1j9)

---
*Initially written Sep 17, 2026 · Reviewed: Sep 17, 2026; Sep 30, 2026; Oct 15, 2026 · Edited: Oct 15, 2026 · Last review: Oct 15, 2026*

Topic: Physical world and mathematics › Physics › Classical physics › Waves and optics › Optical technologies and instruments › Interferometers and optical cavities › Interferometric configurations and techniques › Mach–Zehnder and multi-arm interferometers

Copyright 2026 Edgepedia

License: Edgepedia Community License 1.0, https://www.edgepedia.org/edgepedia/license

Source: https://www.edgepedia.org/mach-zehnder-interferometer